HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

LY/T 2581-2016 English PDF

US$399.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
LY/T 2581-2016: Technical code for forest fire video monitoring system
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
LY/T 2581-2016English399 Add to Cart 3 days [Need to translate] Technical code for forest fire video monitoring system Valid LY/T 2581-2016

PDF similar to LY/T 2581-2016


Standard similar to LY/T 2581-2016

LY/T 2407   LY/T 1184   LY/T 1650   LY/T 2575   LY/T 2576   LY/T 2574   

Basic data

Standard ID LY/T 2581-2016 (LY/T2581-2016)
Description (Translated English) Technical code for forest fire video monitoring system
Sector / Industry Forestry Industry Standard (Recommended)
Classification of Chinese Standard B65
Classification of International Standard 65.020.99
Word Count Estimation 17,164
Date of Issue 2016-01-18
Date of Implementation 2016-06-01
Quoted Standard GB 4208; GB/Z 6829; GB/T 10125-2012; GB 13955; GB/T 17626.5; GB/T 28181; GB 50057; GB 50343; GB 50348; GB 50394; QX/T 105
Regulation (derived from) ?State Forestry Bureau Announcement 2016 No.1
Issuing agency(ies) State Forestry Administration
Summary This standard specifies the functional requirements, system composition, general technical requirements and main technical indexes of the system for forest fire prevention video surveillance. This standard applies to forest fire prevention video surveillance system.

LY/T 2581-2016: Technical code for forest fire video monitoring system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical code for forest fire video monitoring system ICS 65.020.99 B65 People's Republic of China Forestry Industry Standard Forest fire prevention video surveillance system technical specification Released on.2016-01-18 2016-06-01 implementation State Forestry Administration released

Content

Foreword III 1 Scope 1 2 Normative references 1 3 Terms, definitions and abbreviations 1 3.1 Terms and Definitions 1 3.2 Abbreviations 2 4 system function requirements 2 4.1 Basic function requirements 2 4.2 System Control Function 3 4.3 System Interface 3 5 system composition and general technical requirements 3 5.1 Front End System 3 5.2 Network Transmission 4 5.3 Command and Control Center 4 6 System main technical indicators 4 6.1 Basic requirements 4 6.2 Imaging System Requirements 5 6.3 Cruise Cycle 6 6.4 Pyrotechnic Identification 7 6.5 Alarm Positioning 7 6.6 Climate and Environmental Requirements 7 6.7 Surge (impact) immunity 8 Appendix A (Normative) System Control Functions 9 Appendix B (Normative) Service Interface 11 Appendix C (Normative Appendix) GIS Interface 13

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the Office of the National Forest Fire Command. This standard is under the jurisdiction of the National Forest Fire Protection Standardization Technical Committee (SAC/TC523). This standard was drafted. China Jilin Forest Industry Group Co., Ltd., Jilin Forestry Information Technology Co., Ltd., Zhonglinxin Da (Beijing) Science and Technology Information Co., Ltd., Qingdao Haohai Network Technology Co., Ltd., Nanjing Enbo Technology Co., Ltd., National Forestry Bureau Information Center, Institute of Forest Ecology, Environment and Protection, Chinese Academy of Forestry. The main drafters of this standard. Gong Wenyan, Li Bo, Li Shidong, Shu Lifu, Xia Liang, Zeng Zenglun, Wang Shengjie, Cui Guangyuan, Huang Yanjin, Chen Hongsheng, Wu Jia, Feng Xiaoqiang, Meng Decheng, Sun Jian. Forest fire prevention video surveillance system technical specification

1 Scope

This standard specifies the functional requirements, system components and general technical requirements of the forest fire prevention video surveillance system and the main technical indicators of the system. This standard applies to forest fire video surveillance systems (referred to as monitoring systems).

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB 4208 enclosure protection grade (IP code) General requirements for GB/Z 6829 residual current action protection appliances GB/T 10125-2012 Artificial atmosphere corrosion test salt spray test GB 13955 residual current action protection device installation and operation GB/T 17626.5 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test Technical requirements for information transmission, exchange and control of GB/T 28181 security video surveillance networked system GB 50057 lightning protection design code for buildings GB 50343 lightning protection technical specification for building electronic information systems GB 50348 Safety Engineering Technical Specifications GB 50394 Intrusion Alarm System Engineering Design Specification QX/T 105 lightning protection device construction quality supervision and acceptance specification 3 Terms, definitions and abbreviations 3.1 Terms and definitions The following terms and definitions apply to this document. 3.1.1 Front-end monitoring device front-endmonitoringequipment Mainly includes. bearing equipment, camera, lens and other components, should have continuous cruise and preset cruise function; can be reset periodically, with self Dynamic and manual multiple control methods and direct positioning through angle information. 3.1.2 Forest fire video surveillance system forestfirevideomonitoringsystem Mainly by front-end monitoring equipment, pyrotechnic identification system, network transmission system, monitoring tower, power supply security system, security protection system, video surveillance Control management system and other necessary equipment, continuously monitor the fire range of the monitoring scope, realize early detection and timely treatment of fire Intelligent system. 3.1.3 Horizontal angle horizontalangle The front end of the monitoring system monitors the angle between the projection of the optical axis of the device in the horizontal plane and the north direction.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of LY/T 2581-2016_English be delivered?

Answer: Upon your order, we will start to translate LY/T 2581-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of LY/T 2581-2016_English with my colleagues?

Answer: Yes. The purchased PDF of LY/T 2581-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.