US$469.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. LY/T 1056-2012: Forest engineering. Forestry aerial ropeway. Design specification Status: Valid LY/T 1056: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| LY/T 1056-2012 | English | 469 |
Add to Cart
|
3 days [Need to translate]
|
Forest engineering. Forestry aerial ropeway. Design specification
| Valid |
LY/T 1056-2012
|
| LY/T 1056-1991 | English | 919 |
Add to Cart
|
6 days [Need to translate]
|
(Forestry ropeway design specifications)
| Obsolete |
LY/T 1056-1991
|
Standard similar to LY/T 1056-2012 LY/T 1990 LY/T 3115 LY/T 1169
Basic data | Standard ID | LY/T 1056-2012 (LY/T1056-2012) | | Description (Translated English) | Forest engineering. Forestry aerial ropeway. Design specification | | Sector / Industry | Forestry Industry Standard (Recommended) | | Classification of Chinese Standard | P86 | | Classification of International Standard | 65.020 | | Word Count Estimation | 18,173 | | Older Standard (superseded by this standard) | LY/T 1056-1991 | | Quoted Standard | GB/T 9075; GB/T 20118; GB 50127 | | Regulation (derived from) | State Forestry Administration Notice 2012 No. 5; industry standard filing Notice 2012 No. 4 (No. 148 overall) | | Issuing agency(ies) | State Forestry Administration | | Summary | This standard specifies the forestry ropeway design terms and definitions, General Design, cable line layout, equipment selection set cableway, ropeway ropeway line survey and design and design. This standard applies to forestry logging, hauling, loading |
LY/T 1056-2012: Forest engineering. Forestry aerial ropeway. Design specification---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Forest engineering.Forestry aerial ropeway.Design specification
ICS 65.020
P86
People's Republic of China Forestry Industry Standard
Replacing LY 1056-1991
Forest engineering forestry cableway design specification
Published on.2012-02-23
2012-07-01 implementation
State Forestry Administration released
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces LY 1056-1991 "Code for Design of Forestry Aerial Cableway". Compared with LY 1056-1991, the main changes are as follows.
--- Amend the standard name "Design Specification for Forestry Aerial Cableway" to "Design Specification for Forest Engineering Aerial Cableway";
--- Revised the scope of the content (see Chapter 1, Chapter 1 of the.1991 edition);
--- Revised the normative reference documents (see Chapter 2, Chapter 2 of the.1991 edition);
--- Added the terms and definitions of "span, no-load deflection coefficient and safety factor", and deleted the "critical suspension curve, steel wire pole"
Terms and definitions such as "limit strength" (see Chapter 2, Chapter 2 of the.1991 edition);
--- Modified the design of the load cable design (see 8.3,.1991 edition 7.3);
--- Added the content of "ropod line side design" (see 8.4);
--- Added the content of "determining the method of collecting materials" (see 8.5);
--- Revised the "computation of the working cable and the actual power check of the winch" (see 8.6 and 8.7, Chapter 8 of the.1991 edition);
--- Revised part of the original Appendix A and Appendix B (see Appendix A and Appendix B,.1991 editions Appendix A and Appendix B);
--- Removed Appendix C ~ Appendix F (1991 edition Appendix C ~ Appendix F).
This standard is proposed and managed by the National Forest Engineering Standardization Technical Committee (SAC/TC362).
This standard is drafted by. Fujian Agriculture and Forestry University.
Participated in the drafting of this standard. Harbin Forestry Machinery Research Institute, Northeast Forestry University, Central South University of Forestry and Technology.
The main drafters of this standard. Zhou Xinxin, Ma Zhiyuan, Zhang Zhengxiong, Dong Xibin, Wang Zhongwei, Zheng Lifeng, Shen Yufeng, Yang Xuefeng, Wu Zhilong,
Zhou Chengjun.
This standard was first published in August.1991 and this is the first revision.
Forest engineering forestry cableway design specification
1 Scope
This standard specifies the terminology and definition of forestry aerial ropeway design, general design rules, cableway layout, ropeway equipment selection, ropeway route
Survey design and ropeway design.
This standard is applicable to the design of forestry aerial ropeway for forestry skidding, transportation materials and loading and unloading. The design of freight aerial ropeway is also
Can be used for reference.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 9075 rope test and scrap specification
GB/T.20118 general purpose wire rope
Technical specification for GB 50127 aerial ropeway engineering
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Span span
The horizontal distance between adjacent brackets or between the station and adjacent brackets.
3.2
Chord inclination
The angle between the line connecting the fulcrum (chord line) and the horizontal line (sharp angle).
3.3
Non-interference coefficient of non-interferencecoefficientofthesag
The ratio of the central deflection of the no load to the horizontal span is called the unloaded central deflection coefficient of the suspension cable, which is referred to as the no-load deflection coefficient.
3.4
Ascendingangleofcarriage
The angle between the tangent and the horizontal line of the contact point between the wheel of the sports car and the suspension cable.
3.5
Bend angle deflectionangleofchord
The angle formed by the adjacent two spans at the bracket, that is, the angle between the chord of any span and the extension of the adjacent chord (an acute angle).
3.6
Bending angle bendingangleofcablearoundthesaddle
The algebraic sum of the direction angle formed by the slanting curve of the bearing cable between the tangent and the horizontal line on the left and right sides of the bracket saddle, that is, the previous crossover
The angle between the tangential line of the line at the fulcrum and the tangential extension line at the same fulcrum at the same fulcrum curve (sharp angle).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of LY/T 1056-2012_English be delivered?Answer: Upon your order, we will start to translate LY/T 1056-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of LY/T 1056-2012_English with my colleagues?Answer: Yes. The purchased PDF of LY/T 1056-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version LY/T 1056-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version LY/T 1056-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|