US$699.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1472-2014: Calibration Specification for Process Calibrators Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1472-2014 | English | 699 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Process Calibrators
| Valid |
JJF 1472-2014
|
PDF similar to JJF 1472-2014
Basic data Standard ID | JJF 1472-2014 (JJF1472-2014) | Description (Translated English) | Calibration Specification for Process Calibrators | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Classification of International Standard | 17.220 | Word Count Estimation | 30,338 | Date of Issue | 8/1/2014 | Date of Implementation | 11/1/2014 | Quoted Standard | JJF 1309-2011; GB/T 13978-2008; GB/T 15637-2012; GB/T 16839.1-1997; JB/T 8622-1997; JB/T 8623-1997 | Regulation (derived from) | AQSIQ Notice 2014 No. 89 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to an output DC voltage, DC current, DC resistance, frequency, analog thermocouple, RTD analog functions, and both measure AC and DC voltage, AC-DC power supplies, DC resistance, frequency, thermocouple signal, thermal resistance sig |
JJF 1472-2014: Calibration Specification for Process Calibrators---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Process Calibrators
People's Republic of China National Metrology Technical Specifications
Instrument calibration process calibrator specification
Issued on. 2014-08-01
2014-11-01 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Instrument calibration process calibrator specification
Focal point. the National Technical Committee on Electromagnetic measurement
Main drafting unit. Henan Institute of Metrology
Participated in the drafting unit. Shanghai Institute of Measurement and Testing
Metrology hospital in Guizhou Province
Changsha Heng Control Technology Co.,
Beijing Const Instrument Technology Co., Ltd.
This specification commissioned the National Technical Committee Electromagnetic responsible for the interpretation of measurement
The main drafters of this specification.
Chen Qingping (Henan Institute of Metrology)
Ning Liang (Henan Institute of Metrology)
Secretary Zhao Yan (Henan Institute of Metrology)
Maoxiao Chen (Shanghai Institute of Measurement and Testing)
Drafters participate.
Long wave (Guizhou Province Measurement and Testing Institute)
Zhou Xinhua (Changsha Heng Control Technology Co., Ltd.)
He Xin (Beijing Const Instruments Technology Co., Ltd.)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 Metrological characteristics (2)
4.1 Output/measuring range and error limits (2)
4.2 DC current output load characteristic (2)
Calibration Condition 5 (2)
5.1 environmental conditions (2)
5.2 standards and other measuring equipment (2)
6 calibration items and calibration methods (3)
6.1 calibration items (3)
6.2 Calibration method (4)
7 Calibration Results The expression (7)
8 Recalibration interval (8)
Appendix A Measurement Uncertainty Example (a) (9)
Appendix B Measurement Uncertainty Example (b) (12)
Appendix C calibration original record format (15)
Appendix D calibration certificate within the page format (p. 2) (18)
Appendix E calibration certificate calibration results page format (page 3) (19)
Appendix F basic error expression (22)
Differential resistance and thermocouple Seebeck coefficient of thermal resistance of Appendix G (23)
Introduction
This specification based on the national measurement specifications JJF 1071-2010 "National Calibration Specifications writing rules"
JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" establishment.
The specification for the first time to develop.
Instrument calibration process calibrator specification
1 Scope
This instruction applies to an output DC voltage, DC current, DC resistance, frequency, thermocouple analog signals,
RTD analog functions, and both measure AC and DC voltage, DC current, DC resistance, frequency,
Thermocouple signal, thermal resistance signal function process calibrator instrument calibration. It is also applicable to a part of the above measurements and
Output function process calibrator instrument calibration.
2. References
This specification refers to the following documents.
JJF 1309-2011 temperature calibrator calibration specifications
GB/T 13978-2008 DMM
GB/T 15637-2012 General specification for digital multimeter calibrator
GB/T 16839.1-1997 Thermocouples - Part 1. indexing table
JB/T 8622-1997 industrial platinum RTD Technical conditions and indexing table
JB/T 8623-1997 industrial copper heat resistance Technical conditions and indexing table
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Process instrumentation for industrial production processes for monitoring, measurement and control field devices or the health of the system work
meter. Process instrumentation calibrator is mainly used for instrument calibration process, its main feature is both independent signals
Measuring unit and signal output unit, part of the process instrument calibrator and needed some measurements or electrical output
Messages are displayed in the form of its own physical quantity (such as temperature, pressure, etc.).
Process instrumentation calibrator (hereinafter referred to as "the calibrator") is the central control unit as the core digital calibrator
Table, and its block diagram shown in Figure 1.
Block diagram of Figure 1 process instrumentation calibrator
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1472-2014_English be delivered?Answer: Upon your order, we will start to translate JJF 1472-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1472-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1472-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|