HOME   Cart(2)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1147-2006 English PDF

US$579.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1147-2006: Calibration specfication for acoustic performance of anechoic rooms and hemi-anechoic rooms
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1147-2006English579 Add to Cart 4 days [Need to translate] Calibration specfication for acoustic performance of anechoic rooms and hemi-anechoic rooms Valid JJF 1147-2006

PDF similar to JJF 1147-2006


Standard similar to JJF 1147-2006

GB/T 3222.2   GB/T 3222.1   JJG 188   JJG 1190   JJF 2012   JJG 1147   

Basic data

Standard ID JJF 1147-2006 (JJF1147-2006)
Description (Translated English) Calibration specfication for acoustic performance of anechoic rooms and hemi-anechoic rooms
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A59
Word Count Estimation 22,210
Date of Issue 2006-05-23
Date of Implementation 2006-08-23
Quoted Standard JJF 1001-1998; JJF 1059-1999; JJG 176-2005; JJG 449-2001; GB/T 3102.7-1993; GB/T 3947-1996; GB/T 17247.1-2000; ISO 3745-2003; IEC 61094-4 -1995
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to anechoic and semi-anechoic chamber acoustic characteristics to identify and evaluate.

JJF 1147-2006: Calibration specfication for acoustic performance of anechoic rooms and hemi-anechoic rooms


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specfication for acoustic performance of anechoic rooms and hemi-anechoic rooms National Metrology Technical Specification of the People's Republic Calibration specifications for acoustic characteristics of anechoic chambers and semi-anechoic chambers Released on.2006-05-23 Implementation of.2006-08-23 The General Administration of Quality Supervision, Inspection and Quarantine issued Anechoic chamber and semi-anechoic chamber Acoustic characteristic calibration specification This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on May 23,.2006, and Implemented on August 23,.2006. Focal Point. National Acoustic Metrology Technical Committee Drafted by. China Institute of Metrology Institute of Acoustics Shanghai Institute of Metrology and Testing Technology This specification is interpreted by the National Acoustic Metrology Technical Committee. Drafters of this specification. Zhang Meizhen (China Institute of Metrology) Chen Jianlin (China Institute of Metrology) Liu Ke (School of Acoustics, Chinese Academy of Sciences) Gu Jianxiu (Shanghai Institute of Metrology and Testing Technology) Zheng Xiaotong (China Institute of Metrology) Shuai Zhengping (China Institute of Metrology) Bai Hao (China Institute of Metrology)

table of Contents

1 Scope (1) 2 Citations (1) 3 terms and units of measurement (1) 4 Overview (1) 5 Measurement characteristics (1) 5.1 Frequency range and spatial range of free sound field (1) 5.2 Noise floor (2) 6 Calibration conditions (2) 6.1 Environmental conditions (2) 6.2 Calibrators and other equipment (2) 7 Calibration items and calibration methods (3) 7.1 Calibration Project (3) 7.2 Calibration method (4) 8 Calibration result expression (8) 8.1 Calibration Data Processing (8) 8.2 Calibration Certificate (8) 8.3 Evaluation of uncertainty of calibration results (8) 9 re-study interval (8) Appendix A Test Sound Source Selection and Directivity Measurement (9) Appendix B Calculation of Acoustic Absorption by Air (10) Appendix C Contents of the calibration certificate (12) Appendix D Example of Evaluation of Uncertainty of Calibration Results (14) Calibration specifications for acoustic characteristics of anechoic chambers and semi-anechoic chambers

1 Scope

This specification applies to the determination and evaluation of the acoustic characteristics of the anechoic chamber and the semi-anechoic chamber.

2 Citations

This specification refers to the following documents JJF 1001-1998 General Terms and Definitions JJF 1059-1999 "Measurement Uncertainty Evaluation and Representation" JJG176-2005 "Acoustic Calibrator" JJG449-2001 "octave and 1/3 octave filter" GB/T 3102.7-1993 "Amount and unit of acoustics" GB/T 3947-1996 "Acoustic terminology" GB/T 17247.1-2000 "Attenuation of outdoor propagation - Part 1. Calculation of atmospheric sound absorption" ISO 3745-2003 Acoustics-Determinationofsoundpowerlevelsofnoisesourcesus- ingsoundpressure-Precisionmethodsforanechoicandhemi-an- Echoicrooms IEC 61094-4.1995 Measurementmicrophones-Part 4.Specificationsforworking Standardmicrophones Use of this specification should be done with the current valid version of the above cited documents.

3 terms and units of measure

This specification adopts the relevant terms and definitions in GB/T 3947-1996 and JJF 1001-1998 and GB/T. The quantities and units specified in 3102.7-1993.

4 Overview

The anechoic chamber is equipped with high-efficiency sound absorbing materials or sound absorbing members on all sides of the room, so that the boundary can effectively absorb the incident sound. A room in which the indoor space is basically a free sound field; the semi-anechoic chamber is an anechoic chamber with a reflecting surface on one side, Quasi-half free field space, that is, a space above the reflecting surface that is a free sound field. Attenuation chambers and semi-anechoic chambers are widely used Measurement of acoustic performance of various electroacoustic devices and electroacoustic products, metrological calibration of electroacoustic measuring instruments, testing, electromechanical production Precision measurement of acoustic power levels and acoustic research.

5 Measurement characteristics

5.1 Frequency range and spatial extent of the free sound field The free sound field frequency range and spatial range of the anechoic chamber and the semi-anechoic chamber are measured by the indoor sound pressure level and inverse square law The maximum allowable deviation between theoretical values is determined.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1147-2006_English be delivered?

Answer: Upon your order, we will start to translate JJF 1147-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1147-2006_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1147-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.