US$279.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 38330-2019: Code of maintenance and overhaul of inverter for photovoltaic power station Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 38330-2019 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Code of maintenance and overhaul of inverter for photovoltaic power station
| Valid |
GB/T 38330-2019
|
PDF similar to GB/T 38330-2019
Basic data | Standard ID | GB/T 38330-2019 (GB/T38330-2019) | | Description (Translated English) | Code of maintenance and overhaul of inverter for photovoltaic power station | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F12 | | Classification of International Standard | 27.160 | | Word Count Estimation | 14,161 | | Date of Issue | 2019-12-10 | | Date of Implementation | 2020-07-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 38330-2019: Code of maintenance and overhaul of inverter for photovoltaic power station---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Code of maintenance and overhaul of inverter for photovoltaic power station
ICS 27.160
F12
National Standards of People's Republic of China
Inverter overhaul and maintenance procedures for photovoltaic power stations
2019-12-10 release
2020-07-01 implementation
State Administration of Market Supervision
Published by the National Standardization Management Committee
Contents
Foreword I
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Basic requirements 1
5 Overhaul 2
6 Maintenance 5
7 Test 6
Appendix A (Informative) Inverter Maintenance Report 8
Appendix B (informative appendix) Inverter maintenance record table 9
Appendix C (Informative) Inverter Maintenance Record Form 10
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Please note that some elements of this document may involve patents. The issuer of this document is not responsible for identifying these patents.
This standard is proposed and managed by the China Electric Power Enterprise Federation.
This standard was drafted. TBEA Xinjiang New Energy Co., Ltd.
The main drafters of this standard. Li Hong, Zhou Hongwei, Liu Kui, Guo Qing, Yang Baoyan, Zeng Chuanyang, He Yingfei, Zheng Zhihua, Mei Chengwei, Fan Jubao,
Liu Jia, Liang Wuxing, Liu Qiang.
Inverter overhaul and maintenance procedures for photovoltaic power stations
1 Scope
This standard specifies the technical requirements for inspection, maintenance, and testing of photovoltaic power station inverters.
This standard applies to photovoltaic power stations.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 10064 Test method for determining the insulation resistance of solid insulating materials
GB/T 18216.4 Test and measurement of electrical safety protection measures for low voltage distribution systems with AC 1000V and DC 1500V
Or monitoring equipment. Part 4. Ground resistance and equipotential ground resistance
GB/T 24343 Insulation resistance test specification for electrical equipment of industrial machinery
GB 26860 Power safety working code for power plants and substations
GB/T 35694 PV power station safety regulations
GB/T 37408 Technical requirements for grid-connected inverters for photovoltaic power generation
GB/T 37409 Technical Specifications for PV Grid-connected Inverter Detection
3 terms and definitions
The following terms and definitions apply to this document.
3.1
Photovoltaic power generation system
A photovoltaic power generation system that uses the photovoltaic effect of photovoltaic cells to directly convert solar radiant energy into electrical energy.
3.2
Photovoltaic power station
A power station that directly converts solar radiation into electrical energy.
Note. Photovoltaic power stations include photovoltaic power generation systems, and various types of buildings (structures) and auxiliary facilities such as maintenance, maintenance, and living.
3.3
Photovoltaic inverter
A device that converts direct current generated by a photovoltaic square array into alternating current.
4 Basic requirements
4.1 Inverter overhaul and maintenance shall formulate overhaul plans and prepare overhaul plans based on equipment operating status and maintenance records.
4.2 The safety of inverter maintenance work shall meet the requirements of GB 26860 and GB/T 35694.
4.3 The inverter maintenance unit shall have a quality management system and an occupational health and safety system.
4.4 Inverter maintenance personnel should be familiar with the structure, performance and principle of the equipment, master the equipment maintenance process and the emergency rescue method on site.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 38330-2019_English be delivered?Answer: Upon your order, we will start to translate GB/T 38330-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 38330-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 38330-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|