| US$944.00 ยท In stockDelivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
 GB/T 18233.5-2018: Information technology -- Generic cabling for customer premises -- Part 5: Data centres
 Status: Valid
 
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| GB/T 18233.5-2018 | English | 944 | Add to Cart | 5 days [Need to translate] | Information technology -- Generic cabling for customer premises -- Part 5: Data centres | Valid | GB/T 18233.5-2018 |  
	 
       PDF similar to GB/T 18233.5-2018 
 Basic data             | Standard ID | GB/T 18233.5-2018 (GB/T18233.5-2018) |           | Description (Translated English) | Information technology -- Generic cabling for customer premises -- Part 5: Data centres |           | Sector / Industry | National Standard (Recommended) |           | Classification of Chinese Standard | L65 |           | Classification of International Standard | 35.200 |           | Word Count Estimation | 50,577 |           | Date of Issue | 2018-12-28 |           | Date of Implementation | 2018-12-28 |           | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration | GB/T 18233.5-2018: Information technology -- Generic cabling for customer premises -- Part 5: Data centres---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
 Information technology--Generic cabling for customer premises--Part 5. Data centres
ICS 35.200
L65
National Standards of People's Republic of China
Information technology user building group general cable
Part 5. Data Center
Part 5. Datacentres
(ISO /IEC 11801-5..2017, IDT)
Published on.2018-12-28
2018-12-28 implementation
State market supervision and administration
China National Standardization Administration issued
 ContentForeword III
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and definitions, abbreviations 2
3.1 Terms and Definitions 2
3.2 Abbreviations 3
4 Compliance 4
5 universal cabling system structure 4
5.1 Overview 4
5.2 Functional Elements 4
5.3 General structure and hierarchy 5
5.4 Cable Subsystem 6
5.5 Configuration of Functional Elements 7
5.6 Interface 8
5.7 Dimensions and Configuration 9
5.8 Grounding and equipotential bonding 12
6 channel performance requirements 12
6.1 Overview 12
6.2 Environmental performance 13
6.3 Transmission performance 13
7 Link performance requirements 14
7.1 Overview 14
7.2 Balanced cable 14
7.3 Fiber optic cable 14
8 Reference Implementation 14
8.1 Overview 14
8.2 Balanced cable 14
8.3 Fiber optic cable 21
9 Cable Requirements 22
9.1 Overview 22
9.2 Balance Cable 22
9.3 Cable 22
10 Connection Hardware Requirements 22
10.1 General requirements 22
10.2 Balanced cabling hardware 23
10.3 Fiber Optic Cable Connection Hardware 24
11 Jumper Requirements 24
11.1 Quick Jumper 24
11.2 Balance Jumper 25
11.3 Fiber Patch Cable 25
Appendix A (Normative) Balanced cabling link combination 26
Appendix B (informative) Use of high-density connection hardware in fiber optic cable 27
Appendix C (informative) Examples of structures that meet the requirements of this section 30
Appendix D (informative) Network Architecture Example 39
Reference 43ForewordGB/T 18233 "General cable for information technology users' buildings" is divided into the following parts.
--- Part 1. General requirements;
--- Part 2. Office space;
--- Part 3. Industrial buildings;
--- Part 4. Residential;
--- Part 5. Data Center;
--- Part 6. Distributed building facilities.
This part is the fifth part of GB/T 18233.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the translation method equivalent to ISO /IEC 11801-5..2017 "Information Technology User Buildings General Cables Part 5
Points. Data Center.
This standard incorporates the contents of ISO /IEC 11801-5.2017/COR1.2018 and is used in the margins of the outer side of its corresponding clause.
The vertical double line (||) is marked.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
--- GB/T 34961.2-2017 Information technology user building group cabling implementation and operation Part 2. Planning and installation
(ISO /IEC 14763-2.2012, IDT)
Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents.
This part is proposed and managed by the National Information Technology Standardization Technical Committee (SAC/TC28).
This section drafted by. China Electronics Technology Standardization Institute, Shandong Province Computing Center (National Supercomputing Jinan Center), Shenzhen Competition
West Information Technology Co., Ltd., Nexans (China) Cable Co., Ltd., Shanghai Tiancheng Cable Co., Ltd., Shandong Province Economic and Information Development
Research Institute.
The main drafters of this section. Li Gang, Yang Hong, Li Min, Li Mengliang, Wang Junyuan, Wu Jun, Zhao Xiangyang, Feng Zhenggan, Lin Feng, Guo Xiong, Zhou Mingle, Zhang
Built, Li Wang, Yu Yuanhua, Liu Bo, Wang Wei, Liu Yiming.IntroductionCable installations are as important as other infrastructures such as water supply and energy supply, and disruption of cabling system services can also have serious implications. by
Poor service due to lack of planning, improper use of components, improper installation, poor management, or inadequate support may be given to users.
Bring business losses.
This part of GB/T 18233 describes general cabling in data center equipment rooms and access data centers, or other types of buildings.
General cabling within the data center.
In addition, it also includes.
---The cabling of the office space specified in ISO /IEC 11801-2;
--- Cables for industrial sites as specified in ISO /IEC 11801-3.
ISO /IEC 11801-6 specifies cabling for distributed building facilities and also covers all of the above locations and conditions.
Figure 1 shows the relationship between the standards for cabling and information technology reports developed by ISO /IEC JTC1/SC25. which is
Standards for cabling design, installation, operation, and management in ISO /IEC 11801, and test standards for installed cabling.
Figure 1 Relationship between common cabling standards established by ISO /IEC JTC1/SC25
The general cabling specified in this section will provide the following services to users.
a) provide users with a separate cabling system that supports a wide range of applications within the installation and operating environment;
b) Provide users with flexible cabling solutions that make the modifications simple and economical;
c) supply chain of multi-provider cabling components in an open market environment;
In addition to this, this section provides.
d) provide guidance to industry professionals to allow installation of cabling prior to obtaining specific requirements, such as initial plans for construction or renovation,
And when determining future deployment requirements.
e) Provide guidance to the cabling system industry and standards organizations supporting existing products as standardization for future product development and application
basis.
The applications covered in this section include sub-technical committees under the IEC (including sub-technical committees under ISO /IEC JTC1) and
Developed by ITU-T's research group to support high data rate, mission-critical services in a data center space-intensive connection environment.
This section takes into account the application requirements listed in ISO /IEC 11801-1.2017 Appendix E.
This part should be used in conjunction with ISO /IEC 11801-1.2017. The general requirements for general cabling are specified in ISO /IEC 11801-1.2017.
Make the other standards in the ISO /IEC 11801 series have general requirements that can be referenced.
The physical layer requirements for the applications listed in Appendix E of ISO /IEC 11801-1.2017 have been determined to be compatible with the cabling performance specified in this section.
With the statistics of the premises in different countries and the model described in Chapter 6, the requirements for the cabling components are specified and they are specified in the cabling system.
Arrangement.
Therefore, this section describes the cabling structures that support a wide range of applications.
1) Adopt balanced cabling channels and EA, F, FA, I and II links as specified in ISO /IEC 11801-1.2017;
2) Adopt the component requirements specified in ISO /IEC 11801-1.2017 to ensure the performance of a cable for permanent links and channels
Or more than a specific application (eg, level);
3) Adopt the fiber optic cabling channel and link requirements specified in ISO /IEC 11801-1.2017.
The expected life of a typical cabling system depends on environmental conditions, supported applications, the life of the materials used in the cable, and other such as path connections.
Factors such as (the campus path is more difficult to access than the building path). Select the appropriate components and meet the expected life expectancy of the cabling system at least in accordance with this section.
For 10 years.
This section takes into account the application requirements listed in ISO /IEC 11801-1.2017 Appendix E, and also refers to the relevant components and testers.
The relevant standards of the law.
Information technology user building group general cable
Part 5. Data Center1 ScopeThis part of GB/T 18233 specifies general cabling for equipment rooms and access rooms in data center buildings, or other types of buildings.
General cabling for in-data centers, including balanced cabling and fiber optic cabling.
This section is mainly applicable to buildings with a maximum telecommunications service distance of.2000m. Systems with larger distances can be used as reference.
The cabling system specified in this section supports a wide range of applications, including audio, data and video, as well as power.
This section is directly or by reference to ISO /IEC 11801-1.2017.
a) the structure and minimum configuration of the general cabling in the data center;
b) equipment outlet (EO) interface and external network interface (ENI);
c) performance requirements for cabling links and channels;
d) requirements and options for implementation;
e) performance requirements for cabling components;
f) Compliance requirements and verification procedures.
Safety (electrical safety and protection, fire protection, etc.) and electromagnetic compatibility (EMC) requirements are regulated by other standards and regulations and are not included in this section.
In the range. However, the information given in this section helps to comply with these standards and specifications.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
ISO /IEC 11801-1.2017 General cable for information technology users - Part 1. General requirements
technology-Genericcablingforcustomerpremises-Part 1.Generalrequirements)
ISO /IEC 14763-2 Implementation and operation of information technology user building cabling - Part 2. Planning and installation
(Informationtechnology-Implementationandoperationofcustomerpremisescabling-Part 2.Plan-
Ningandinstalation)
ISO /IEC 30129 Telecommunications connection network for information technology buildings and other building structures (Informationtechnology-
Telecommunicationsbondingnetworksforbuildingsandotherstructures)
IEC 60603-7-7 Connectors for electronic equipment - Part 7-7. 8-channel active for data transmission up to 600 MHz
And detailed specifications for fixed shielded connectors (Connectorsforelectronicequipment-Part 7-7.Detailspecification
For8-way,shielded,freeandfixedconnectors,fordatatransmissionswithfrequenciesupto600MHz)
IEC 60603-7-41 Connectors for electronic equipment - Part 7-41. 8-channel activity for data transmission up to 500 MHz
Detailed specification for fixed and fixed unshielded connectors (Connectorsforelectronicequipment-Part 7-41. Detailspecifi-
Cationfor8-way, unshielded, freeandfixedconnectors, fordatatransmissionswithfrequenciesupto
500MHz)
IEC 60603-7-51 Connectors for electronic equipment - Part 7-51. 8-channel activity for data transmission up to 500 MHz
Detailed specification for fixed and fixed shielded connectors (Connectorsforelectronicequipment-Part 7-51.Detail
Specificationfor8-way,shielded,freeandfixedconnectors,fordatatransmissionswithfrequenciesup
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18233.5-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 18233.5-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 18233.5-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18233.5-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.    |