US$294.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 15142-2011: Secondary cells and batteries containing alkaline or other non-acid electrolytes -- Vented nickel-cadmium prismatic rechargeable single cells Status: Valid GB/T 15142: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 15142-2011 | English | 294 |
Add to Cart
|
3 days [Need to translate]
|
Secondary cells and batteries containing alkaline or other non-acid electrolytes -- Vented nickel-cadmium prismatic rechargeable single cells
| Valid |
GB/T 15142-2011
|
| GB/T 15142-2002 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Square openings nickel-cadmium single cells specification
| Obsolete |
GB/T 15142-2002
|
| GB/T 15142-1994 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
General specification for nickel-cadmium alkaline rechargeable single cells
| Obsolete |
GB/T 15142-1994
|
PDF similar to GB/T 15142-2011
Basic data | Standard ID | GB/T 15142-2011 (GB/T15142-2011) | | Description (Translated English) | Secondary cells and batteries containing alkaline or other non-acid electrolytes -- Vented nickel-cadmium prismatic rechargeable single cells | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K82 | | Classification of International Standard | 29.220.01 | | Word Count Estimation | 15,137 | | Date of Issue | 2011-12-30 | | Date of Implementation | 2012-07-01 | | Older Standard (superseded by this standard) | GB/T 15142-2002 | | Quoted Standard | GB/T 2900.41-2008; IEC 60051-1; IEC 60051-2; IEC 60051-3; IEC 60051-4; IEC 60051-5; IEC 60051-6; IEC 60051-7; IEC 60051-8; IEC 60051-9; IEC 60410; IEC 60417-1; IEC 60417-2; IEC 60485; IEC 61438 | | Adopted Standard | IEC 60623-2001, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 23 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the square vented nickel-cadmium batteries monomer logo, type, dimensions, tests and requirements. If there are other standard battery test conditions used for special purposes and requirements, and with the contents of this conflict, the former should be given priority. |
GB/T 15142-2011: Secondary cells and batteries containing alkaline or other non-acid electrolytes -- Vented nickel-cadmium prismatic rechargeable single cells ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Secondary cells and batteries containing alkaline or other non-acid electrolytes. Vented nickel-cadmium prismatic rechargeable single cells
ICS 29.220.01
K82
National Standards of People's Republic of China
Replacing GB/T 15142-2002
Containing alkaline or other non acid electrolytes
And batteries
Square monomer vented nickel-cadmium batteries
(IEC 60623.2001, IDT)
Issued on. 2012-07-01 2011-12-30 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 General 1
1.1 Scope 1
1.2 Normative references 1
1.3 Terms and Definitions 1
1.4 parameter measurement tolerance 2
2 models and mark 2
2.1 Battery Type 2
2.2 Battery Connection 2
2.3 Flag 2
2.4 Safety Recommendation 2
Dimensions 2 3
4 Electrical Test 4
4.1 Test method for charging 4
4.2 discharge performance 4
4.3 charge retention capability 6
4.4 Durability 7
4.5 constant voltage charge acceptance capacity of 70,000
4.6 Overcharge 8
4.7 exhaust valve operation 8
4.8 Electrolyte retention test 8
4.9 Storage 8
5 Mechanical Test 8
8 6 Appearance
7 type of inspection and batch reception conditions 8
7.1 Type inspection 8
7.2 Batch received 9
Figure 1 has two terminals and four lugs vented steel shell square cell Example 3
Table 1a Steel Case Square vented nickel-cadmium batteries Dimensions 3
Table 1b square plastic vented nickel-cadmium batteries Dimensions 3
Table 2 Measurement tolerances 4
Table 3 20 ℃ discharge performance 5
Table 4 5 ℃ discharge performance 5
Table 5 -18 ℃ discharge performance 6
Table 6 large current value 6
Table 7 7 life cycle
Table 8 constant voltage charging conditions 7
Table 9 type examination test sequence 9
Table 10 Recommended grant received test sequence 9
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is identical with IEC 60623.2001 "and batteries containing alkaline square vented or other non acid electrolytes
Single nickel-cadmium batteries. "
This standard made the following editorial changes.
a) "this International Standard" be replaced by "this standard";
b) use a decimal point instead of a decimal comma ",". ",";
c) Remove the preface to international standards.
This standard replaces GB/T 15142-2002 "square opening single nickel-cadmium battery master specification."
This standard compared with GB/T 15142-2002, the main changes are as follows.
--- Standard IEC standard is consistent with the name (Home edition and covers);
--- Model named using IEC standards (edition 2.1);
--- Increased 5 ℃ discharge performance test (this version 4.2.2);
--- Increasing the high current test (this version 4.2.4);
--- Cycle life test methods vary from the requirements of 550 reduced to 500 (Excerpts 4.4.1,2002 version 4.7 and 5.9);
--- Constant voltage charge acceptance test severities increase, lengthening the charge time and discharge time after the test requirements (edition 4.5,
2002 version 4.6 and 5.8);
--- The air tightness test plug to the electrolyte retention test (Excerpts 4.8,2002 version 4.1 and 5.3);
--- Test to identify stereotypes test (Excerpts 7.1,2002 version 6.2);
--- Remove the test cycle, the test batch to batch acceptance inspection (Excerpts 7.2,2002 version 6.3);
--- Remove the packaging, transportation, storage, delivery and other aspects of the requirements (Chapter 7 edition 2002).
The standard international normative documents referenced in the correspondence between the consistency of the following documents.
--- GB/T 7676 (all parts) Direct acting indicating analogue electrical measuring instruments and their accessories [IEC 60051 (all parts)].
The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This standard by the National Standardization Technical Committee alkaline batteries (SAC/TC77) centralized.
This standard was drafted. China Electronics Standardization Institute.
The main drafters of this standard. SUN Chuan Hao, Zhao Lihua.
This standard replaces the standards previously issued as follows.
--- GB/T 15142-1994; GB/T 15142-2002.
Introduction
Manufacturers and users of batteries and alkaline batteries, used to represent multiples capacity battery and battery charge and discharge of electricity
flow. For example. The nominal capacity of 100Ah battery with 20A current charging current can be expressed as C/5A or 0.2CA. This current
Representation for early standard alkaline batteries and battery-related in.
Many comments indicate that this method has a current dimension error that capacity (Ah) multiple of the unit is safe, not the current unit
ampere. For this reason, this International Standard IEC 61434 for current formulation methods.
In short, with this way of expressing the standard test current It (A) as follows.
ItA = CnAh/1h
Where.
Cn --- declared by the manufacturer rated capacity, in units of Ah (Ah);
n --- declared by the manufacturer rated capacity time base in hours (h).
Containing alkaline or other non acid electrolytes
And batteries
Square monomer vented nickel-cadmium batteries
1 General
1.1 Scope
This standard specifies the square monomer vented nickel-cadmium battery symbol, type, dimensions, tests and requirements.
Note. This standard, the "square" refers to the side and bottom of the battery is rectangular.
If there are other standard specifies the test conditions and requirements for batteries used for special purposes, and clashed with the contents of this standard should be excellent
First use of the former.
1.2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2900.41-2008 Electrotechnical terminology primary cells and batteries (IEC 60050-482.2003, IDT)
IEC 60051 (all parts) Direct acting indicating analogue electrical measuring instruments and their accessories (Directactingindicatinganalogue
electricalmeasuringinstrumentsandtheiraccessories)
IEC 60410 count inspection Sampling plans and procedures (Samplingplansandproceduresforinspectionbyattrib-
utes)
IEC 60417 (all parts), Graphical symbols for equipment [Graphicalsymbolsforuseonequipment (alparts)]
IEC 60485 DC Electronic digital voltmeter and electronic DC Converters (Digitalelectronicd.c.voltmeters
andd.c.electronicanalogue-to-digitalconverters)
IEC 61438 basic and batteries may present a danger to health and the hazards - equipment manufacturers and users
Guide (Possiblesafetyandhealthhazardsintheuseofalkalinesecondarycelsandbatteries-Guidetoe-
quipmentmanufacturersandusers)
1.3 Terms and Definitions
GB/T 2900.41-2008 defined and the following terms and definitions apply to this document.
1.3.1
Vented battery ventedcel
Cover has a channel through which the gaseous product may escape batteries.
1.3.2
Nominal voltage nominalvoltage
Monomer vented nickel-cadmium battery nominal voltage of 1.2V.
1.3.3
Rated capacity ratedcapacity
Declared by the manufacturer electricity C5Ah (ampere-hours). That single battery under the conditions specified in Chapter 4 of the charging and discharging after shelving,
At 20 ℃ 0.2ItA standard test current discharge to the termination voltage of 1.0V can output power.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 15142-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 15142-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 15142-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 15142-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 15142-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15142-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|