   US$229.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 12009.3-2009: Plastics -- Polyethylene polyphenol isocyanate -- Part 3: Determination of viscosity Status: Valid  GB/T 12009.3: Evolution and historical versions  
      
    
  
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF | 
		 
			| GB/T 12009.3-2009 | English | 229 | 
   Add to Cart
   | 
                    3 days [Need to translate]
                 | 
                    Plastics -- Polyethylene polyphenol isocyanate -- Part 3: Determination of viscosity
                 | Valid | 
                    GB/T 12009.3-2009
                 | 
		 
			| GB/T 12009.3-1989 | English | 199 | 
   Add to Cart
   | 
                    2 days [Need to translate]
                 | 
                    Polymethylene polyphenyl isocyanate--Determination of viscosity
                 | Obsolete | 
                    GB/T 12009.3-1989
                 | 
		 
	 
     
     
  
	 
       PDF similar to GB/T 12009.3-2009 
    
   
    
     
          
  
  
    
  Basic data             |  Standard ID  |          GB/T 12009.3-2009 (GB/T12009.3-2009) |               |  Description (Translated English)  |          Plastics -- Polyethylene polyphenol isocyanate -- Part 3: Determination of viscosity |               |  Sector / Industry  |          National Standard (Recommended) |               |  Classification of Chinese Standard  |          G31 |               |  Classification of International Standard  |          83.080 |               |  Word Count Estimation  |          10,199 |               |  Date of Issue  |          2009-06-15 |               |  Date of Implementation  |          2010-02-01 |               |  Older Standard (superseded by this standard)  |          GB/T 12009.3-1989 |               |  Adopted Standard  |          ISO 3219-1993, MOD |               |  Regulation (derived from)  |          National Standard Approval Announcement 2009 No.8 (Total No.148) |               |  Issuing agency(ies)  |          General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |               |  Summary  |          This standard specifies the coaxial double cylindrical rotary viscometer viscosity methods. This section applies to multi- polymethylene polyphenyl isocyanate ester viscosity measurement.  |         
  GB/T 12009.3-2009: Plastics -- Polyethylene polyphenol isocyanate -- Part 3: Determination of viscosity ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.  
Plastics Polymethylene polyphenyl isocyanate Part 3. Determination of viscosity
ICS 83.080
G31
National Standards of People's Republic of China
Replacing GB/T 12009.3-1989
Plastic polymethylene polyphenyl isocyanate
Part 3. Determination of viscosity
(ISO 3219.1993, Plastics-Polymers/resinsintheliquidstateor
usingarotationalviscometerwithdefinedshearrate, MOD)
Posted 2009-06-15 2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 12009 "plastic polymethylene polyphenyl isocyanate" is divided into five sections.
--- Part 1. Determination of total chlorine content;
--- Part 2. Determination of hydrolyzable chlorine content;
--- Part 3. Determination of viscosity;
--- Part 4. Determination of isocyanato content;
--- Part 5. Determination of acidity.
This section GB/T Section 312,009, modifications adopted ISO 3219.1993 "plastic liquid state or as emulsions or dispersions of poly
Polymer/resin was measured at a rotational viscometer with defined shear rate viscosity "(in English).
This section according to ISO 3219.1993 redrafted in order to facilitate comparison, are listed in this section with informative Appendix B
ISO 3219.1993 technical differences, and in the text with a single vertical line identification.
For ease of use, this section made the following editorial changes.
a) to the "international standards" be replaced by "this section";
b) Remove the ISO 3219.1993 Foreword;
c) increase the national standard foreword;
d) For the ISO 3219.1993 international standard other references have been adopted as the equivalent of a standard, this part of the country with references
National standards instead of the corresponding international standards;
e) use of decimal notation. "" instead of the international standard decimal symbol "."
This Part replaces GB/T 12009.3-1989 "polymethylene polyphenyl isocyanate viscosity measurement method."
This section compared with the GB/T 12009.3-1989 The main changes are as follows.
--- Shear rate gives two series;
--- Precision instrument made provisions;
--- Measured for 3 times;
--- Added two appendices;
--- Increasing the viscosity meter calibration;
--- Circulating bath temperature (0 ~ 50) ℃ range can be constant at ± 0.2 ℃;
--- Increase the accuracy of the thermometer should be 0.05 ℃.
Appendix A to this part of the normative appendix, Appendix B is an informative annex.
This part is proposed by the China Petroleum and Chemical Industry Association.
This part of the National Standardization Technical Committee of plastic products and plastic resins General Methods Chapter (SAC/TC15/SC4) centralized.
This section is responsible for drafting. National Quality Supervision and Inspection Center of synthetic resin.
This section participated in the drafting unit. China National Bluestar (Group) Co., Ltd., Lansing (Tianjin) Chemical Co., Ltd., Cangzhou Dahua Group Company
Secretary of Jiangsu Province Chemical Research Institute Co., Ltd., Yantai Wanhua Polyurethane Co., Ltd.
The main drafters of this section. Wang Yan, Cai Liang Zhen, Wang, Zhang root Shan, Liu Rong, He Ping.
This part of the standard replaces the previous editions are.
--- GB/T 12009.3-1989.
Plastic polymethylene polyphenyl isocyanate
Part 3. Determination of viscosity
1 Scope
This section GB/T 12009 gives the coaxial having a predetermined shear rate double cylindrical rotary viscometer viscosity method.
This section applies to multi-polymethylene polyphenyl isocyanate ester viscosity measurement.
Principle 2
With used with the specified characteristics of the viscometer according to the shear rate and shear stress measurements obtained viscosity liquid sample.
(1) viscosity η is defined by the formula.
η =
γ
(1)
Where.
--- viscosity [eta], in units of Pascal seconds (Pa · s);
[tau] --- shear force unit Pascals (Pa);
γ --- shear rate in second (s-1).
According to the International System of Units (SI) unit of viscosity is Pascal seconds (Pa · s)
1Pa · s = 1N · s/m2
Note 1. Sign and GB 3102.3 "Quantities and units of mechanics' agreement.
Kwan called Newtonian liquids.
3 Instrument
3.1 rotational viscometer
3.1.1 Measuring System
Measurement system shall include coaxial surfaces of two rigid symmetrical, during which the viscosity of the fluid into the test. Wherein a surface at a constant angular velocity
Degree rotation, while the other surface remain stationary. Measurement system should be determined for each measurement of the shear rate.
Torque measuring device shall be connected to a surface which can be measured so as to overcome the viscous resistance of the fluid torque required.
Suitable for the coaxial cylinder measuring system system.
Size measurement system shall meet the conditions specified in Appendix A, which is designed to ensure that all test measurement types and all common models of the instrument
Weight region having a similar geometry.
3.1.2 basic instrument
Basic instrument should be designed to be able to install alternative rotor and the stator to form a series of predetermined rotational frequency (stepwise or continuously
Change), and the corresponding torque can be measured, and vice versa (ie. generating a predetermined torque and rotational frequency corresponding measurements).
Torque measuring instrument accuracy should be within the full scale count of 2%. Within the normal operating range of the instrument, the instrument precision rotational frequency
Degree should be within 2% of the measured value. Viscosity measurement repeatability shall be ± 2%.
Note. For different measuring systems and the rotational frequency of use, most have a viscosity measuring instruments means that range, the minimum range (10-2 ~
103) Pa · s.
A shear rate range of different instruments vary widely, it should be based on the viscosity and shear rate range of measurements required to select a particular
On the basis of appropriate instruments and measurement systems.
   
   
  
  
    
  Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 12009.3-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 12009.3-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 12009.3-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 12009.3-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):  List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to  [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 12009.3-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 12009.3-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.  
        
   
        
       
          
               
 
          |