US$439.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 46034-2025: Fire safety inspection rules for public assembly occupancies prior to opening of businesses Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 46034-2025 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Fire safety inspection rules for public assembly occupancies prior to opening of businesses
| Valid |
GB 46034-2025
|
Standard similar to GB 46034-2025 GB/T 51033 GB/T 50082
Basic data | Standard ID | GB 46034-2025 (GB46034-2025) | | Description (Translated English) | Fire safety inspection rules for public assembly occupancies prior to opening of businesses | | Sector / Industry | National Standard | | Classification of Chinese Standard | C80 | | Classification of International Standard | 13.220.01 | | Word Count Estimation | 22,235 | | Date of Issue | 2025-08-01 | | Date of Implementation | 2026-02-01 | | Issuing agency(ies) | State Administration for Market Regulation, Standardization Administration of China |
GB 46034-2025: Fire safety inspection rules for public assembly occupancies prior to opening of businesses ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB46034-2025
ICS 13.220.01
CCSC80
National Standard of the People's Republic of China
Public gathering places put into use and open for business
Fire Safety Inspection Rules
Released on August 1, 2025
Implementation on February 1, 2026
State Administration for Market Regulation
The National Standardization Administration issued
Table of Contents
Preface III
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 General Requirements 1
5 Document Review 2
6 On-site inspection 2
7 Comprehensive Assessment 9
8 File Management 9
Appendix A (Informative) Requirements for the content of the site layout plan and site fire protection facilities layout plan 10
Appendix B (Informative) Fire Safety Inspection Record Form for Public Gathering Places Put into Use and Operation 11
Reference 17
Preface
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents"
Drafting.
Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents.
This document is proposed and coordinated by the National Fire and Rescue Administration.
introduction
According to the Fire Protection Law of the People's Republic of China, which was amended on April 29, 2021, fire safety inspections for public gathering places are required.
The applicant can choose whether to use the notification and commitment method. Fire rescue agencies will conduct inspections on public gathering places that have made commitments.
Verification will be carried out and inspections will be conducted on public gathering places that do not adopt the notification and commitment method.
To standardize the fire safety inspection of public gathering places put into use, prevent and reduce fires, and safeguard social and economic development
This document is formulated in accordance with the Fire Protection Law of the People's Republic of China and other relevant laws, regulations and fire protection technical standards in order to protect the lives and property of the people.
Public gathering places put into use and open for business
Fire Safety Inspection Rules
1 Scope
This document stipulates the overall requirements, document review, on-site inspection, comprehensive evaluation and other requirements for fire safety inspection of public gathering places before they are put into use.
and file management.
This document is applicable to fire safety inspections of public gathering places put into use by fire rescue agencies, including inspections of places that adopt the notification and commitment method.
Verify the places that handle the procedures in the informed consent manner and inspect the places that do not handle the procedures in the informed consent manner.
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to
This document.
GB/T 5907 (all parts) Fire protection vocabulary
GB 25203 Fire supervision technical equipment
GB/T 40248 Fire safety management in crowded places
GB 55036 General Specification for Fire-Fighting Facilities
GB 55037 General Code for Fire Protection of Buildings
3 Terms and Definitions
The terms and definitions defined in GB/T 5907 (all parts), GB/T 40248 and the following apply to this document.
3.1
A general term for facilities installed in buildings for fire alarm, fire extinguishing, smoke prevention and exhaust, and personnel evacuation.
Note. Fire protection facilities include automatic fire alarm system, automatic fire extinguishing system, fire hydrant system, smoke and exhaust system, emergency broadcast and emergency lighting, safe evacuation system, etc.
Scattered facilities, etc.
3.2
importantitem
During the fire safety inspection of public gathering places, violations of fire laws and regulations and non-compliance with fire technical standards may be found.
Various unsafe situations that may cause fire or increase fire hazards and cannot be corrected on the spot.
3.3
Other items
Except for important matters found during the fire safety inspection of public gathering places before they are put into use, if the problems can be corrected on the spot or within a specified period, the minor offenses shall be investigated.
Various unsafe matters such as minor fire safety violations or fire hazards with relatively minor hazards.
4 General Requirements
Fire safety inspections of public gathering places that have been put into use and are open for business shall comply with the following requirements.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 46034-2025_English be delivered?Answer: Upon your order, we will start to translate GB 46034-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 46034-2025_English with my colleagues?Answer: Yes. The purchased PDF of GB 46034-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|