GB 14536.5-2008: [GB/T 14536.5-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type
Status: Obsolete

GB 14536.5: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 14536.5-2008English754 Add to Cart 3 days [Need to translate] [GB/T 14536.5-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type Obsolete GB 14536.5-2008
GB 14536.5-1996English479 Add to Cart 3 days [Need to translate] Automatic electrical controls for household and similar use. Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type Obsolete GB 14536.5-1996

PDF similar to GB 14536.5-2008


Standard similar to GB 14536.5-2008

GB 14536.16   GB 14536.8   GB 14536.15   GB/T 14536.7   GB/T 14536.12   GB/T 14536.1   

Basic data

Standard ID GB 14536.5-2008 (GB14536.5-2008)
Description (Translated English) [GB/T 14536.5-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type
Sector / Industry National Standard
Classification of Chinese Standard K32
Classification of International Standard 29.130.20
Word Count Estimation 19,193
Date of Issue 2008-12-30
Date of Implementation 2010-02-01
Older Standard (superseded by this standard) GB 14536.5-1996
Quoted Standard GB 14536.1
Adopted Standard IEC 60730-2-4-2006, IDT
Regulation (derived from) Announcement of Newly Approved National Standards No. 26 of 2008 (total 139)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Chinese standard specifies the evaluation method for closed (sealed and semi- sealed) motor-compressor part. Test requirements of motor and motor thermal protection are specified in GB 4706. 17-2004. This standard applies to an NTC or PTC thermistor motor-compressor and motor thermal protection. This standard applies to the inherent safety equipment, and equipment for the operation of safety-related values??, the operating time and operating procedures, as well as for installation in or into closed (hermetic and semi-hermetic type) motor-compressor motor thermal protection. This standard also applies to GB 4706. 17-2004 within the compressor motor a motor thermal protector. Note: this standard uses the"Device"includes"appliances and equipment. "Not intended as a general household purposes compressor motor thermal protection, but may still be used by the public, such as going in shops, in light industry and farm equipment used by the non-professionals, the use of motor-compressors with thermal protection is still within the scope of this standard. This standard does not apply specifically for industrial applications motor thermal protector. 1. 1. 2 this standard does not apply to other motor protective measures. 1. 1. 3 this standard does not apply to disconnect the circuit

GB 14536.5-2008: [GB/T 14536.5-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Automatic electrical controls for household and similar use.Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type ICS 29.130.20 K32 National Standards of People's Republic of China GB 14536.5-2008/IEC 60730-2-4.2006 Replacing GB 14536.5-1996 Household and similar electrical automatic controller Sealed and semi-hermetic motor - compressors Particular requirements for thermal motor protectors (IEC 60730-2-4.2006, IDT) Posted 2008-12-30 2010-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ IEC Introduction Ⅲ 1 Scope and normative references 1 2 Definitions 2 3 2 General requirements 4 General notes 2 Rating 2 5 6 Category 2 Profile 3 7 8 4 Protection against electric shock 9 ground protection measures 4 10 Terminals and terminations 4 11 structural requirements 4 Moisture and dust 12 5 13 Electric strength and insulation resistance 5 14 Fever 5 15 Manufacturing deviation and drift 5 16 5 Environmental Stress 17 5 Durability 18 mechanical strength 7 19 Threaded parts and connections 8 20 creepage distances, clearances and distances through solid insulation through 8 21 heat, fire and resistance to tracking 9 22 corrosion 9 23 Electromagnetic compatibility (EMC) emission requirements --- 9 24 assembly 9 25 Normal operation 9 26 Electromagnetic compatibility (EMC) requirements --- immunity 9 27 non-normal operation 9 28 Guidelines for the use of electronic disconnect 9 Appendix 10 Annex C (normative) mercury switch test cotton 10 Appendix E (normative) measure leakage current of the circuit 10 Annex AA (normative) Thermal motor protectors as a durability test element, for example, the motor 11 is not loaded GB 14536.5-2008/IEC 60730-2-4.2006

Foreword

All technical content in this section is mandatory. GB 14536 "Household and similar electrical automatic controller" is divided into two parts. --- Part 1. General requirements; --- Part 2. Particular requirements. Special requirements and consists of the following components. --- GB 14536.3 - Particular requirements for thermal motor protectors (IEC 60730-2-2, IDT); --- Particular requirements GB 14536.4 tubular fluorescent lamp ballasts for thermal protectors (IEC 60730-2-3, IDT); --- GB 14536.5 sealed and semi-hermetic motor - compressor motor thermal protection Particular requirements (IEC 60730-2-4, IDT); --- Particular requirements GB 14536.6 automatic electrical burner control systems (IEC 60730-2-5, IDT); --- GB 14536.7 pressure sensitive electrical controls - Particular requirements (idt IEC 60730-2-6); --- GB 14536.8 Particular requirements for timers and time switches (idt IEC 60730-2-7); --- GB 14536.9 Particular requirements for electrically operated water valves (including mechanical requirements) (IEC 60730-2-8, IDT); --- GB 14536.10 - Particular requirements for temperature sensing controls (IEC 60730-2-9, IDT); --- GB 14536.11 Particular requirements for motor starting relays (IEC 60730-2-10, IDT) used; --- GB 14536.12 Particular requirements for energy regulators (idt IEC 60730-2-11); --- GB 14536.13 Particular requirements for electrically operated door locks (IEC 60730-2-12, IDT); --- GB 14536.15 Particular requirements for humidity sensing controls (IEC 60730-2-13, IDT); --- GB 14536.16 Particular requirements for electric actuators (idt IEC 60730-2-14); --- GB 14536.17 special requirements of the float or electrode-sensitive automatic electrical water level sensing controller used in the boiler appliance (IEC 60730-2-15, IDT); --- GB 14536.18 - Particular requirements for household and similar use of the float type level controllers (IEC 60730-2-16, IDT); --- GB 14536.19 Particular requirements for electrically operated gas valves, including mechanical requirements (IEC 60730-2-17, IDT); --- GB 14536.20 Particular requirements for water and air flow sensing controls, including mechanical requirements (IEC 60730-2-18, IDT); --- GB 14536.21 Particular requirements for electrically operated oil valves, including mechanical requirements (IEC 60730-2-19, IDT); This section identical with IEC 60730-2-4.2006 "Household and similar electrical automatic controller Part 2. hermetic and semi electric Motivation - Compressor motor thermal protector of special requirements. " Part of this structure with IEC 60730-2-4.2006 same. In this section, there is a corresponding national standard, incorporated by reference to national standards; No national standards, IEC standards are incorporated by reference outlined. Scheduling order with IEC Part 1 of Chapter normative references documents Different 60730-2-4. For ease of use, this section made the following editorial changes. a) "This standard" be replaced by "this section"; b) use a decimal point instead of a decimal comma ",". ","; c) increase the national standard foreword. This part of GB 14536.1-2008 "Household and similar electrical controls - Part 1. General requirements" in conjunction. This Part replaces GB 14536.5-1996 "household and similar use of hermetic and semi automatic controller for motor - compressors Special requirements "thermal motor protectors. GB 14536.5-2008/IEC 60730-2-4.2006 Compared with GB 14536.5-1996 part of the main changes are as follows. a) the name of several sections according to changes GB 14536.1 made the appropriate changes; b) in Chapter 1, the rated voltage range capped by 660V to 690V; c) Chapter 7 Table 7.2 has some changes; d) Appendix AA new content; e) the requirements of Appendix H to change. This part of the Appendix C, Appendix E is normative annex, appendix AA informative appendices. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee household automatic control (SAC/TC212) centralized. This section is drafted. Guangzhou CVC Testing Institute, Guangzhou Electric Apparatus Research Institute, Wanbao Refrigeration Group Guangzhou Electrical Appliance Co., Division Hangzhou Star Shuai Seoul Electric Co., Ltd. Foshan Tongbao, Lanxi City, the Electric Appliance Co., Ltd. Changzhou Chang Rong Electric Co. Division Shunde Yung your measurement Electric Co., Ltd., Zhejiang Yan Thermostat Co., Emerson Electric (Shenzhen) Co., beads Hailing Of Compressor Co., Ltd., China Household Electrical Appliances Research Institute. Drafters of this section. Core hole Xun, Zhu Liping, Huang Kaiyun, Huang Zhi Hang, Lu Wencheng, wheat harvest, high Yonghua, Kuangfa Rong, Hedui Qi, Chen Yonglong, Zhou happiness, Chen Daguang, Jiayu Lin. This part of the standard replaces the previous editions are. --- GB 14536.5-1996. GB 14536.5-2008/IEC 60730-2-4.2006 IEC Foreword 1) IEC (International Electrotechnical Commission) is a worldwide standardization group composed of national electrotechnical committees (IEC National Committees) Organizations. The object of IEC is to promote international cooperation on issues related to the standardization of the electrical and electronic fields. For this purpose IEC addition to other activities, but also publishes International Standards, technical specifications, technical reports, public specification (PAS, Publicly AvailableSpecifications) and guidelines (henceforth referred to IEC publication). Their preparation is entrusted to technical Commission to complete. As a member of IEC National Committees, as long as the interest of the standard to be developed, may participate Its formulation. Liaising with the IEC 's international, official or unofficial organizations are also involved in the development of standards. IEC and the World Organization for Standardization (ISO ) in accordance with the conditions specified in the agreement, close cooperation. 2) since each technical committee has representatives from the National Commission on the relevant issues of interest, so the IEC on technical Issue formal decisions or agreements on the maximum expression of the international consensus on the relevant issues. 3) IEC Publications have the form of recommendations for international use, and accepted by the National Committees in that sense. Despite being made There are possible effort to ensure that the technical content of IEC publications is correct, IEC these publications can not be used Way or misinterpretation of any user and responsibility. 4) In order to promote international unification, IEC National Committees in charge of the IEC international standards transparently converted to the maximum extent possible National or regional standards. Between the IEC Standard and the corresponding national or regional standard if there is any difference, it should be converted into the standard After clearly illustrates. 5) IEC did not develop any signs of approval procedure, when a device if it complies with the IEC declared a publication, which is not IEC Accountable. 6) All users should make sure you have the latest version of this publication. 7) IEC or its leaders, employees, servants or agents, including independent experts and IEC technical committees, national committee Members will, for the use of any person or the trust of the IEC standards or other IEC publication caused casualties, property damage Loss or other damage to the natural environment (whether such losses are direct or indirect) does not bear any responsibility for the phase Should produce costs and expenses (including legal fees) is not liable. 8) To take note of the standard referenced standards. Use the referenced standard is correct application of this standard essential. 9) It is noteworthy that this International Standard may involve some parts of the patent. IEC for the identification of some or all of this A Class of the patent will be irresponsible. IEC 60730-2-4 international standard by the IEC Technical Committee TC72. home automation controller developed. This second edition cancels and replaces the first edition in 1994 and its amendments 1 and 2001 amendments enacted in 1990 2. The second edition of the group Into a technical revision and update of the standard to meet the current practice while also parallel with the use of the standard. Standard text based on the following documents. FDIS Report on voting 72/710/FDIS 72/723/RVD For more information on this standard a vote, the vote on the report, see the table below. Drafting of the publication to comply with ISO /IEC Guide. Part II. The second part of the book used in conjunction with IEC 60730-1. This requirement was established in 1999, the third edition of IEC 60730-1 and 2003 Amendment 1 basis. IEC 60730-1 should be considered in subsequent versions or revisions. This part supplements or modifies the corresponding provisions in IEC 60730-1 so as to be converted to the corresponding IEC standards. hermetic and semi electric Motivation - Particular requirements for compressor motor thermal protection. GB 14536.5-2008/IEC 60730-2-4.2006 When appearing in this part of the "addition", "modification" or "replacement", the general requirements of the relevant requirements, test description or explanatory content should Amended accordingly. When no change, this section will indicate the appropriate sections or provisions apply. In the development of a full international standard, we must consider the different requirements of the actual situation of the various regions of the world is formed, and should be recognized Differences in each country's electrical systems and wiring rules. Differences in different countries in order to "Note. In some countries," given in the form of these differences, see the following terms. --- 6.101; --- 101 Table 7.2; --- 12.2; --- 17.2; --- Table 17.2; --- 17.2.1; --- 17.2.2; --- 18.1.3.101.2; --- 20.1; --- 20.2; --- 20.3; --- 20.3.1; --- Table 20.3.101; --- Appendix D. Use the following printed in this section. --- Body requirements. roman; --- Test specifications. italic; --- Note matters. small roman type. For the first part of sub-clause is part of the newly added, comments, or items shown are numbered starting from 101, and the newly added Appendix Places letters AA, BB starts. All belong to the IEC 60730 series, attributed to "household and similar use automatic controller" list of categories of standards, in the IEC Get on the website. The Committee decided that the contents of this publication in the IEC website http. // webstore. iec. On ch marked, and specific publications related Remain unchanged until the next revision date. And to this date, the publication will be. ● reconfirmed; ● Cancel; ● The revised version was replaced; or ● Amendment. GB 14536.5-2008/IEC 60730-2-4.2006 Household and similar electrical automatic controller Sealed and semi-hermetic motor - compressors Particular requirements for thermal motor protectors

1 Scope and normative references

GB 14536.1 of the chapter is applicable except as follows. 1.1 Replacement. This section applies to GB 14536.1 defined, closed (hermetic and semi) electric motor - part of the evaluation of the compressor. Note. The motor thermal protection is dependent on a properly installed and secured to the motor or inside the motor, and only in conjunction with the corresponding motor together into Complete test line integral controller. The motor and motor thermal protection combined with the test requirements specified in GB 4706.17-2004 in. This part of the motor is suitable for use NTC or PTC thermistors - compressor motor thermal protection, additional requirements Mitsuke Record J. 1.1.1 This section applies to the inherent safety equipment, safety equipment suitable for operations related to the value of the operating time and operating procedures, and appropriate Motor thermal protection of the compressor test - closed (hermetic and semi) used to hold the motor or load. This section also applies within the scope of GB 4706.17-2004 motor - Motor thermal protection of the compressor. Note. "device" in this section include the use of the term "appliances and equipment." Not intended as a general-purpose household electric motor - compressor thermal protection, but can still be used by the public, such as going to the store, light Workers in industry and farm equipment from non-professional use, its use motor - compressor thermal protection is still within the scope of this section. This section does not apply to thermal motor protectors designed for industrial applications. 1.1.2 This section does not apply to other motor protection measures. 1.1.3 This section does not apply to manual means breaking the circuit. 1.2 Replacement. This section applies to rated voltage not exceeding 690V, thermal protection rated output of 11kW or less motors. Note. comply with this part of the controller is considered to be in line with GB 14536.3 "Household and similar electrical controls for thermal motor protectors special Requirements "requirements. 1.3 Replacement. This section does not consider the response of the controller depends on the controller automatic action device mounting method of. If the response to protection User and the surrounding environment is significant, by the corresponding equipment requirements or applicable value specified by the manufacturer. 1.5 Normative References The following documents contain provisions which, through reference in this Part of GB 14536, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. increase. GB 13539.1 low-voltage fuses - Part 1. General requirements (GB 13539.1-2008, IEC 60269-1.2006, IDT) GB 13539.3 low-voltage fuses - Part 3. unskilled personnel Supplementary requirements for fuses (mainly used for household and class Like fuses purposes) standardized systems of fuses A to Example F (GB 13539.3-2008, IEC 60269-3.2006, IDT) GB 14536.5-2008/IEC 60730-2-4.2006 GB 4706.17-2004 household and similar electrical appliances motor - compressors Particular requirements (IEC 60335-2-34. 1999, IDT)

2 Definitions

GB 14536.1 of the chapter is applicable except as follows. 2.6 Test procedure controller automatically and the type of action related to the definition of increase. 2.6.101 The reliability of its operating characteristics can only be protected in accordance with the motor - the results of measurements carried out on the compressor to evaluate. 2.13 Other definitions increase. 2.13.101 The compressor and motor housed within the same enclosure with no external shaft seal (sealed or semi-sealed) mechanical compressor, motor Cooled in the work environment. By welding or brazing (For sealed compressor), the housing permanent closure, or with one or more infill Joints (semi-hermetic compressors) the housing seal.

3 General requirements

GB 14536.1 of this chapter shall apply. General Description 4 Test GB 14536.1 of the chapter is applicable except as follows. 4.3.1.1 and 4.3.1.2 do not apply. 4.3.2 Not applicable.

5 RATINGS

GB 14536.1 in this chapter does not apply. Category 6 GB 14536.1 of the chapter is applicable except as follows. 6.4 Classification by automatically operating characteristics 6.4.1 Not applicable. 6.4.2 Replacement. --- 3 type action. 6.4.3 Replacement. According to the structural features and operating characteristics of one or more of the type 3 operation further classified. Note 1. The further classification of these only during the relevant statements and has undertaken a number of suitable test applicable under. Note 2. having more than one property with the appropriate action can be classified letter combinations, for example. 3. C. L-type. Note 3. The manual operation is not classified according to the Terms. 6.4.3.1 vacancies. 6.4.3.2 --- micro-off operation (3.B type). GB 14536.5-2008/IEC 60730-2-4.2006 6.4.3.3 --- micro-cutting operation (3.C type). 6.4.3.4 vacancies. 6.4.3.5 vacancies. 6.4.3.6 vacancies. 6.4.3.7 vacancies. 6.4.3.8 --- free trip, in this institution, not hinder contacts open, and if the reset mechanism in the Reset position, when After the safe operating conditions resume, the trip mechanism is automatically reset to the closed position (3.H). 6.4.3.101 Motor thermal protection according to the following characteristics of the structure and operation of re Category. --- Non-automatic reset (3.B.H type); --- Automatic reset (3.C type). increase. 6.101 Press Limited short-circuit capacity classification (Canada and the United States applicable) NOTE. For more information on defining short-circuit test, see 17.2. Not all have the ability to design products safely sustain or breaking short-circuit current without causing the risk of fire. There is clear evidence When can explain no risk of fire when an unprotected motor short circuit, because the circuit will be because of over-current power supply Action protection device safely powered down. However, if in the event of a fault current path in the presence of thermal protection, when this protection is to try to When the fault has been eliminated due to the arc of interference may lead to fires. Such interference is indeed possible to disconnect the power supply of the overcurrent protection circuit before production Students. 17.2 The test that is used to assess the thermal motor protection action in such situations.

7 Information

GB 14536.1 of the chapter is applicable except as follows. 7.2.6 Replacement. For hermetic motor - compressor motor thermal protection, to provide information in accordance with Table 7.2. Table 7.2 instead. Information chapter, strip method 1 manufacturer's name or trade mark 7.2.6 C 2 unique models mark a) 2.11.1,2.13.1,7.2.6 C Use the controller 4.3.5,6.3 X 6 7 g each type of load control circuit) 6.2,17 X PTI values used insulating material 30 6.13 X 31 controller installation methods 8 X Grounding method 31a controller 7.4.3,9 D 43 cutting operation reset characteristic c) 6.4,11.4 X Pollution level controller 49 6.5.3 X 51 fire resistant classification 21 X 101 Limited short-circuit capacity, if you declare 101) 6.101,17.2 X 102 feature automatic operation 102) 6.4 D GB 14536.5-2008/IEC 60730-2-4.2006 Table 7.2 (Continued) Information chapter, strip method The maximum pressure of 103 protector placed in a sealed compressor withstand 103) 18.1.3.101.1 D Note. a) The only model of such a sign is a sign that when fully referenced this flag, the controller will be able to offer manufacturers in the electrical and mechanical properties, dimensional And the new controller with the original controller function exactly the same. Other marks may be such as ambient temperature or voltage rating and a series of models composed together to provide a unique model flag. c) a manufacturer can declare lower than 11.4.102 specified ambient temperature. g) For more than a circuit controller, should indicate the current applicable to each circuit and each terminal; if these currents different from each other, then you should say clearly Chu Which circuit current value which applies or which terminal to. For circuit and inductive load circuit resistance load, should be indicated in the corresponding table 17.2 Rated current or rated load (VA) given the power factor. 101) Canada and the United States apply. 102) Thermal motor protectors are classified into three. B. H and 3. C type. 103) depending on the test pressure refrigerant and the protection position (high or low) in the compressor. Its value in reference GB 4706.17-2004 22.7.

8 Protection against electric shock

GB 14536.1 of this chapter shall apply.

9 ground protection measures

GB 14536.1 of this chapter shall apply. 10 Terminals and terminations GB 14536.1 of the chapter is applicable except as follows. 10.1 does not apply. Terminals and terminations 10.2 connecting the internal conductor increase. NOTE. For this section, the internal wiring line is considered to be ready to lead. 11 structural requirements GB 14536.1 of the chapter is applicable except as follows. 11.3.4 set by the manufacturer of increase. NOTE. potting compound, locking screws and the like are considered to meet the objectives. 11.4 Action increase. 11.4.101 3. B. H-type action should be able to meet the provisions of the disconnected micro electric strength requirements. Through the relevant requirements in Chapter 13 and Chapter 20 of the test to check whether meet the requirements. 11.4.102 3. B. H-action should be designed to ensure that, when the reset mechanism in the reset position will not interfere with the contacts open and automatically Reset to the closed position. Test ambient temperature is above -5 ℃, the controller shall not be automatically reset. GB 14536.5-2008/IEC 60730-2-4.2006 Compliance is checked by looking through the inspection test, the test force is applied to the starter element is not necessary. 11.4.103 3. C-type actions should be provided through micro cutting off the circuit. By the relevant requirements of Chapter 20 to check whether meet the requirements. 12 moisture and dust GB 14536.1 of the chapter is applicable except as follows. 12.2 proof test increase. Note 1. In Canada and the United States, according to Appendix D in the humidity test. Note 2. In Japan, this evaluation is the motor - carried out on the compressor. 13 Electric strength and insulation resistance GB 14536.1 of the chapter is applicable except as follows. increase. Note 1. The test of the applicability of Chapter 13 may depend on the thermal protector in the device installation method. Note 2. If the first 13 test results do not represent the results of the thermal protector in the electrical obtained in, then these tests should normally be contained in equipment get on. Fever 14 GB 14536.1 in this chapter does not apply. NOTE. For thermal motor protection, to complete GB 4706.17-2004 or appropriate IEC standards are considered to be adequate. 15 Manufacturing deviation and drift GB 14536.1 in this chapter does not apply. 16 Environmental Stress GB 14536.1 of this chapter shall apply. 17 Durability GB 14536.1 of the chapter, replaced by the following. 17.1 General requirements NOTE. The motor - compressor motor thermal protector durability requirements abnormal test is replaced by GB 4706.17-2004 in...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 14536.5-2008_English be delivered?

Answer: Upon your order, we will start to translate GB 14536.5-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 14536.5-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB 14536.5-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 14536.5-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 14536.5-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.