(Sampling method for copper and lead anode slime)
| Valid |
YS/T 87-2021
|
| YS/T 87-2009 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Methods for sampling and sample perparation of copper anode slime and lead anode slime
| Obsolete |
YS/T 87-2009
|
| YS/T 87-1995 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
(Copper, lead anode slime gold, silver Sampling and Preparation Methods)
| Obsolete |
YS/T 87-1995
|
PDF similar to YS/T 87-2021
Basic data | Standard ID | YS/T 87-2021 (YS/T87-2021) | | Description (Translated English) | (Sampling method for copper and lead anode slime) | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H60 | | Word Count Estimation | 8,897 | | Issuing agency(ies) | Ministry of Industry and Information Technology |
YS/T 87-2009: Methods for sampling and sample perparation of copper anode slime and lead anode slime ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for sampling and sample perparation of copper anode slime and lead anode slime
ICS 77.150
H60
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 87-1995
Copper, lead anode slime sampling and sample preparation method
Posted 2009-12-04
2010-06-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
Instead of the standard YS/T 87-1995 "copper, lead anode slime of gold, silver analysis sampling and sample preparation method."
Compared with this standard YS/T 87-1995, mainly the following modifications.
--- The standard name changed to "copper, lead anode slime sampling and sample preparation methods," to expand the scope of application of the standard;
--- Increasing the sample preparation method mix;
--- Increasing the flow chart of sample preparation sample;
--- Increasing the sample water sample measured parallel alignment process;
--- Increasing the sample preparation equipment and tool requirements;
--- Increasing the amount of sample preparation requirements;
--- The inspection lot like arbitration adjustment from 30 days to 45 days;
--- Moisture measurement accuracy by a sense of balance is not more than 0.1g, adjust the scale value is not more than 0.01g;
--- Original sample volume less than 2kg, modify parts of the sample volume of not less than 70g, the inspection lot like amount of not less than 3kg;
--- The original sample size by the final revised to 0.125mm 0.098mm;
--- Modify the original sample amount, the original water sample 3.5, 3.6 component sample;
--- Will lead anode slime water bag may not exceed 20%, adjusted to 30%.
This standard by the National Standardization Technical Committee of non-ferrous metals and centralized.
This standard is drafted by. Daye Nonferrous Metals Company.
Participated in the drafting of this standard. Tongling Nonferrous Metals Group Holdings Co., Ltd., Zhuzhou Smelter Group Co., Ltd., Shaanxi Dongling smelting
Lian Co., MCC Huludao Nonferrous Metals Group Co., Ltd.
The main drafters of this standard. Cheng Xi, Hu Xinping, Zhang Zelin, Pan Jie, Bi Jianming, Chen Qinglin, Li Jun.
This standard replaces the standards previously issued as follows.
--- YS/T 87-1995.
Copper, lead anode slime sampling and sample preparation method
1 Scope
This standard specifies the copper, lead anode slime sampling and sample preparation method terminology, general provisions, sampling, sample preparation, moisture determination, preservation and specimen
label.
This standard applies to bags and bulk (tub, box or in tanks) delivery copper, lead anode slime of sampling and sample preparation.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 8170 repair value expressed about the rules and limit values and judgment
GB/T 14260 heavy nonferrous metals flotation concentrates in bulk sampling and sample preparation General
3 Terms
3.1
A certain amount of material in one delivery of the same specifications. Consignment may be composed of one or more inspection lot.
3.2
To determine the grade and designated sampling unit.
3.3
From the inspection lot to a one-time action to obtain samples of a certain quality.
3.4
The samples were taken from a batch of test samples of all parts of the merger of certain quality.
3.5
Test sample for determining the moisture content and chemical composition.
4 General Provisions
Inspection Lot 4.1 bagged material is not greater than 5t. Both supply and demand of delivery must be the same size plastic bags lined bags, bulk only
Internal delivery use.
4.2 Delivery bagged anode slime bag generally is 50kg, the water should not exceed 30%.
4.3 Sampling with the kind of solder is not less than the inner diameter of 16mm.
4.4 Sampling and sample preparation used equipment, tools and sample filled containers must be kept clean, anti-acid, dried and durable. Sheng sample container should be better seal
Resistance, to prevent sample deterioration.
4.5 In the sample preparation process should prevent moisture and any change in composition of the sample and pollution.
4.6 Arbitration chemical composition sample should be properly kept for 45 days for inspection.
|