US$659.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 75-2022: Standard Platinum-10%Rhodium/Platinum Thermocouples Status: Valid JJG 75: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 75-2022 | English | 659 |
Add to Cart
|
5 days [Need to translate]
|
Standard Platinum-10%Rhodium/Platinum Thermocouples
| Valid |
JJG 75-2022
|
JJG 75-1995 | English | 559 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of the Standard Platinum-10% Rhodium/Platinum Thermocouple
| Obsolete |
JJG 75-1995
|
JJG 75-1982 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Verification Regulation of the Standard Platinum Rhodium 10-Platinum Thermocouple
| Obsolete |
JJG 75-1982
|
PDF similar to JJG 75-2022
Basic data Standard ID | JJG 75-2022 (JJG75-2022) | Description (Translated English) | Standard Platinum-10%Rhodium/Platinum Thermocouples | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A54 | Word Count Estimation | 32,398 | Date of Issue | 2022-12-27 | Date of Implementation | 2023-06-27 | Issuing agency(ies) | State Administration for Market Regulation |
JJG 75-2022: Standard Platinum-10%Rhodium/Platinum Thermocouples---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National Metrology Verification Regulations of the People's Republic of China
Standard Platinum Rhodium 10-Platinum Thermocouple
Released on 2022-12-27
2023-06-27 Implementation
Released by the State Administration for Market Regulation
Standard Platinum Rhodium 10-Platinum Thermocouple Verification Regulations
Replace JJG 75-1995
Responsible Unit. National Temperature Measurement Technical Committee
Main drafting unit. China Institute of Metrology
Participated in the drafting unit. Beijing Institute of Metrology and Testing Sciences
Hubei Institute of Metrology and Testing Technology
Xinjiang Uygur Autonomous Region Institute of Metrology and Testing
Kunming Dafang Automatic Control Technology Co., Ltd.
Fluke Testing Instruments (Shanghai) Co., Ltd.
This regulation entrusts the National Temperature Measurement Technical Committee to be responsible for interpretation
The main drafters of this regulation.
Zheng Wei (National Institute of Metrology)
Participating drafters.
Tang Lei (National Institute of Metrology, China)
Zhang Xiwen (Beijing Institute of Metrology and Testing Sciences)
Luo Xiaoping (Hubei Provincial Institute of Metrology and Testing Technology)
Xue Wenyan (Xinjiang Uygur Autonomous Region Institute of Metrology and Testing)
Li Fuhong (Kunming Dafang Automatic Control Technology Co., Ltd.)
Chen Yu [Fluke Testing Instruments (Shanghai) Co., Ltd.]
Table of contents
Introduction (Ⅱ)
1 Scope(1)
2 References(1)
3 Overview(1)
4 Metrological performance requirements (2)
4.1 Thermoelectric characteristics (2)
4.2 Stability(2)
5 General technical requirements (2)
5.1 Electrodes(3)
5.2 Identification(3)
5.3 Structure (3)
6 Measuring Instrument Control(3)
6.1 Test conditions (3)
6.2 Verification items (5)
6.3 Verification method (5)
6.4 Processing of verification results (8)
6.5 Verification period(9)
Appendix A (0~1085)℃ Temperature Zone Standard Platinum Rhodium 10-Platinum Thermocouple Thermoelectromotive Force-Temperature Calculation Method (10)
Appendix B Platinum Rhodium 10-Platinum Thermocouple Thermoelectromotive Force-Temperature Reference Function (11)
Appendix C Verification Record Format (14)
Appendix D Verification Certificate/Verification Result Notification Inner Page Format (17)
Appendix E Special Requirements for Calibration of Standard Platinum-Rhodium 10-Platinum Thermocouples with Fixed Sleeve (18)
Appendix F Example of Verification Result Calculation (19)
Appendix G Additional Cleaning Methods for Standard Platinum-Rhodium 10-Platinum Thermocouples(20)
Appendix H Measurement Uncertainty Evaluation Example (21)
Introduction
JJF1002 "Rules for Writing National Metrology Verification Regulations", JJF1001 "General Metrology Terms and Definitions",
JJF1059.1 "Assessment and Expression of Measurement Uncertainty" together constitute the basic series supporting the formulation and revision of this regulation
specification.
Compared with JJG 75-1995, except editorial modifications, the main technical changes are as follows.
--- Increased the introduction part;
--- Extend the lower limit of the scope of application of the regulations to 0°C;
--- Increase the description of the standard thermocouple structure;
--- The requirements for the thermal electromotive force of thermocouples have been adjusted;
--- Deleted the operation part of making thermocouple;
---Adjusted some verification operation methods;
--- Deleted the differential method measurement;
--- Added the content of standard platinum-rhodium 10-platinum thermocouple with fixed casing structure.
The previous releases of JJG 75-1995 are as follows.
---JJG 75-1982;
--- Gauge (G) Heat-5-1965.
Standard Platinum Rhodium 10-Platinum Thermocouple Verification Regulations
1 Scope
This regulation is applicable to the first-class and second-class standard platinum-rhodium 10-platinum thermocouples at (0~1084.62) °C for the first verification and subsequent verification.
Continue checking.
2 References
JJF1007-2007 Terms and definitions of temperature measurement terms
GB/T 1598-2010 Platinum rhodium 10-platinum thermocouple wire, platinum rhodium 13-platinum thermocouple wire, platinum rhodium 30-platinum rhodium 6 heat
Galvanic wire
GB/T 16839.1 Thermocouple Part 1.Electromotive force specification and tolerance
For dated references, only the dated version applies to this regulation; for undated references
document, its latest version (including all amendments) applies to this regulation.
3 Overview
Thermocouples use the Seebeck effect to measure temperature. Platinum Rhodium 10-Platinum Thermocouple
It is a thermometer with high accuracy and good physical and chemical properties in the thermocouple series.
Platinum-rhodium 10-platinum thermocouple, its positive pole (SP) is a platinum-rhodium alloy containing 10% rhodium, and its negative pole (SN) is pure platinum. standard platinum
Rhodium 10-platinum thermocouples are mainly used for temperature value transmission, and can also be used for precision temperature measurement in a wider range.
The basic structure of a standard platinum-rhodium 10-platinum thermocouple is shown in Figure 1.Electrodes and double-hole ceramic tubes (alumina content is not low
at 95%) constitute the most basic structure of a standard platinum-rhodium 10-platinum thermocouple. The outer diameter of the double-hole ceramic tube is ϕ (3~4)mm,
The hole diameter is ϕ (0.8~1.0)mm, the length is (500~550)mm, the appearance is clean and no breakage is allowed. usually at
The exposed electrode part of the standard platinum-rhodium 10-platinum thermocouple is covered with a section of plastic insulating tube, and this junction should be maintained during use.
structure to avoid electrode short circuit and external contamination.
A part of the standard platinum-rhodium 10-platinum thermocouple is equipped with a removable ceramic outer sheath on the basis of the basic structure
tube, encapsulating the reference terminal and leading out the measurement line, the structure is shown in Figure 2.It is mainly used for base metal thermocouples and armored
Calibration of thermocouples or direct temperature measurement. This type of thermocouple needs to remove the ceramic outer protective sleeve before the verification. other features
See Appendix E for special requirements.
Figure 1 Schematic diagram of the basic structure of a standard platinum-rhodium 10-platinum thermocouple
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 75-2022_English be delivered?Answer: Upon your order, we will start to translate JJG 75-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 75-2022_English with my colleagues?Answer: Yes. The purchased PDF of JJG 75-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 75-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 75-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|