JJG 1070-2011: Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method)
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1070-2011English509 Add to Cart 4 days [Need to translate] Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method) Valid JJG 1070-2011

PDF similar to JJG 1070-2011


Standard similar to JJG 1070-2011

JJF 1070   GB/T 3222.2   GB/T 3222.1   JJF 1070.3   

Basic data

Standard ID JJG 1070-2011 (JJG1070-2011)
Description (Translated English) Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method)
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A59
Classification of International Standard 17.140
Word Count Estimation 22,236
Date of Issue 2011-07-04
Date of Implementation 2011-10-04
Quoted Standard JJF 1001-1998; JJF 1034-2005; GB/T 3102.7-1993; GB/T 3223-1994; GB/T 3947-1996; GB/T 15611-1995; IEC 62127-2-2007
Regulation (derived from) AQSIQ Announcement No. 104 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the frequency range of 0. 5MHz ~ 5MHz used standard hydrophone initial verification, testing and use of follow-up checks.

JJG 1070-2011: Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method) State verification procedures People's Republic of China 0.5MHz ~ 5MHz standard hydrophone (B transducer reciprocity method) 0.5MHzto5MHz (Two-transducerReciprocityMethod) Issued on. 2011-07-04 2011-10-04 implementation The State Administration of Quality Supervision, Inspection and Quarantine released 0.5MHz ~ 5MHz standard hydrophone (B transducer reciprocity method) test procedures The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on July 4, 2011, and from From October 4, 2011 into effect. Focal point. the National Committee of the acoustic measurement technology Drafted by. China Shipbuilding Industry Corporation seventh fifteen Institute China Institute of Metrology The measurement procedure commissioned the National Technical Committee is responsible for interpreting acoustics The drafters of the regulations. Wangyue Bing (China Shipbuilding Industry Corporation seventh fifteen Institute) Huang Yongjun (China Shipbuilding Industry Corporation seventh fifteen Institute) Yang Ping (China Institute of Metrology) He Tao (China Shipbuilding Industry Corporation seventh fifteen Institute)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 terminology and units of measurement (1) 4 Overview (2) 5 metering performance requirements (2) 5.1 of the work (2) 5.2 free field [voltage] sensitivity level (2) 5.3 free field [voltage] sensitivity level frequency response (2) 6 General Requirements (2) 6.1 General Requirements (2) 6.2 Materials and Structures (2) 6.3 mark and factory data (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 Verification Project (4) 7.3 Verification Methods (5) 7.4 Verification Results Processing (7) 7.5 test cycle (7) Appendix A calculation of the effective radius of the transducer (8) Appendix B transducer reciprocity and non-linear test method (9) Appendix C calculated correction factor k (10) Appendix D calibration certificate and test results of notice-page format (12) Measurement Uncertainty Appendix E Examples (14) 0.5MHz ~ 5MHz standard hydrophone (two transducer reciprocity method) test procedures The procedure using the national standard GB/T 15611-1995 "high frequency acoustic hydrophone calibration" in the two transducers Reciprocity law.

1 Scope

This procedure is applied at a frequency standard hydrophone within 0.5MHz ~ 5MHz range used for initial verification, Verification and subsequent use of the check.

2 Citations

The regulations cited in the following documents. JJF1001-1998 common measurement terms and definitions JJF1034-2005 acoustic measurement terminology and definitions GB/T 3102.7-1993 Quantities and units of acoustics GB/T 3223-1994 Acoustics underwater acoustic transducer free-field calibration method GB/T 3947-1996 Acoustics Terminology GB/T 15611-1995 high frequency acoustic hydrophone calibration IEC 62127-2.2007 ultrasound - Hydrophones - Part II. up to 40MHz frequency ultrasound field school Associate (Ultrasonics-Hydrophones-Part 2. Calibrationforultrasonicfieldsupto40MHz) When using this procedure, it should pay attention to using the currently valid version of the documents cited.

3 terminology and units of measurement

This procedure uses JJF1001-1998, JJF1034-2005, GB/T 3947-1996 and the related terms definition. This procedure uses quantities and units GB/T 3102.7-1993 prescribed. NOTE. If no special instructions, this procedure all the voltage, current, sound pressure values refer to valid values. 3.1 from Easy calibration self-reciprocitycalibration Using only reciprocal transducer and a reflector made free-field reciprocity calibration. NOTE. Self-calibration is generally easy to apply to the high-frequency hydrophones. 3.2 two transducers reciprocity calibration two-transducerreciprocitycalibration By the auxiliary transducer generates and easily via self calibration value be known sound field hydrophone calibration methods. 3.3 Apparent send current response apparenttransmittingcurrentresponse Assuming perfect plane wave measurement conditions, the plane wave received by the sound pressure applied to the input terminal of the current ratio. Symbols. S * 1 Unit. Pa · m/A 3.4 apparent free field [voltage] sensitivity apparentfree-field [voltage] sensitivity Under the assumption that the ideal plane wave measurement conditions, the open circuit voltage output of the hydrophone and hydrophone introduced in free field Than the sound pressure at the position of the acoustic center of its existence before.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1070-2011_English be delivered?

Answer: Upon your order, we will start to translate JJG 1070-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1070-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1070-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.