US$689.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 2028-2023: Calibration Specification for Impulse Measuring Systems - Impulse Voltage - Part 1: Impulse Voltage Dividers Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JJF 2028-2023 | English | 689 |
Add to Cart
|
6 days [Need to translate]
|
Calibration Specification for Impulse Measuring Systems - Impulse Voltage - Part 1: Impulse Voltage Dividers
| Valid |
JJF 2028-2023
|
Standard similar to JJF 2028-2023 JJF 1033 JJF 1030 JJG 2028
Basic data | Standard ID | JJF 2028-2023 (JJF2028-2023) | | Description (Translated English) | Calibration Specification for Impulse Measuring Systems - Impulse Voltage - Part 1: Impulse Voltage Dividers | | Sector / Industry | Metrology & Measurement Industry Standard | | Word Count Estimation | 31,313 | | Date of Issue | 2023-03-15 | | Date of Implementation | 2023-09-15 | | Issuing agency(ies) | State Administration for Market Regulation |
JJF 2028-2023: Calibration Specification for Impulse Measuring Systems - Impulse Voltage - Part 1: Impulse Voltage Dividers ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National Metrology Technical Specifications of the People's Republic of China
JJF 2028-2023
Calibration specifications for impulse measurement systems Impulse voltage
Part 1: Impulse voltage dividers
Released on 2023-03-15
2023-09-15 Implementation
Released by the State Administration for Market Regulation
Specification for Calibration of Shock Measuring Systems
Impulse voltage
Part 1: Impulse voltage dividers
Systems-ImpulseVoltage-
Responsible Unit: High Voltage Metrology Sub-Technical Committee of National Electromagnetic Metrology Technical Committee
Main drafting unit: National High Voltage Metering Station
State Grid Hebei Electric Power Co:, Ltd: Electric Power Research Institute
Shanghai Institute of Metrology and Testing Technology
Participating in the drafting unit: State Grid Hubei Electric Power Co:, Ltd: Electric Power Research Institute
Jiangsu Institute of Metrology
Wuhan Pandian Technology Co:, Ltd:
This specification entrusts the National Electromagnetic Metrology Technical Committee High Voltage Metrology Sub-Technical Committee to be responsible for interpretation
The main drafters of this specification:
Liu Shaobo (National High Voltage Metering Station)
Long Zhaozhi (National High Voltage Metering Station)
Pan Jin (Electric Power Research Institute of State Grid Hebei Electric Power Co:, Ltd:)
Pan Yang (Shanghai Institute of Metrology and Testing Technology)
Participating drafters:
Ren Xiang (Electric Power Research Institute of State Grid Hubei Electric Power Co:, Ltd:)
Pan Baoxiang (Jiangsu Institute of Metrology)
Sun Jun (Wuhan Pandian Technology Co:, Ltd:)
Table of contents
Introduction (Ⅱ)
1 Scope(1)
2 References(1)
3 terms(1)
4 Overview(1)
5 Metrological characteristics(2)
5:1 Voltage divider ratio(2)
5:2 Time parameter(2)
5:3 Linearity(2)
6 Calibration conditions(2)
6:1 Environmental conditions (2)
6:2 Standard measuring devices and other equipment (3)
7 Calibration Items and Calibration Methods(4)
7:1 Calibration items(4)
7:2 Calibration method(4)
8 Calibration Results(8)
9 Recalibration interval(9)
Appendix A Impulse Voltage Waveform Definition and Parameter Calculation (10)
Appendix B Example of Measurement Uncertainty Evaluation of Impulse Divider Voltage Divider Ratio and Time Parameter Calibration Results (14)
Appendix C Calibration Raw Record Format(19)
Appendix D Calibration Certificate Inner Page Format (23)
Introduction
JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Standards", JJF 1001-2011 "General Metrology Terminology and
"Definition" and JJF 1059:1-2012 "Assessment and Expression of Measurement Uncertainty" jointly constitute the support for the formulation of this specification
basic documents:
This specification is published for the first time:
Calibration specifications for impulse measurement systems Impulse voltage
Part 1: Impulse voltage dividers
1 Scope
This specification is applicable to impulse currents for measuring lightning impulse voltages and operating impulse voltages with rated voltages of 1kV and above:
Calibration of voltage dividers: This specification does not apply to impulse voltage dividers for measuring lightning impulse chopping voltage with wavefront truncated
calibration:
2 References
This specification references the following documents:
GB/T 16927:1-2011 High Voltage Test Technology Part 1: General Definitions and Test Requirements
GB/T 16927:2-2013 High Voltage Test Technology Part 2: Measurement System
For dated references, only the dated version applies to this specification; for undated references
document, its latest version (including all amendments) applies to this specification:
3 terms
The following terms and definitions defined in GB/T 16927:1 and GB/T 16927:2 apply to this specification:
3:1 Voltage division ratio voltageratio
The ratio of the input voltage to the output voltage of a surge voltage divider:
3:2 Standard lightning impulse voltage standardlightning-impulsevoltage
Smooth lightning impulse voltage with a wave front time of 1:2 μs and a half-peak time of 50 μs:
Note 1: Generally, the wave front time is 0:84μs~1:56μs, and the half-peak time is 40μs~60μs, which can be considered as standard lightning impulse
Voltage:
Note 2: Oscillation near the overshoot and peak value is permissible, and the relative overshoot amplitude is allowed not to exceed 10%:
[Source: GB/T 16927:1-2011, 7:2:1, modified]
The cut-off time is the standard lightning impulse voltage cut off by the external gap with a cut-off time of 2μs~5μs:
[Source: GB/T 16927:1-2011, 7:2:3, modified]
3:4 Standard operating impulse voltage standardswitching-impulsevoltage
Impulse voltage with a peak time of 250μs and a half-peak time of 2500μs:
Note: Generally, the peak time is:200μs~300μs, and the half-peak time is 1000μs~4000μs, which can be considered as standard operation shock
Voltage:
[Source: rewritten GB/T 16927:1-2011, 8:2:1, with modifications]
4 Overview
Impulse voltage divider is a measuring device used to measure impulse voltage, which can convert the measured impulse high voltage to a certain proportion:
|