HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJF 1448-2014 English PDF

US$369.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1448-2014: Calibration Specification for Superconducting Pulsed Fourier Transform Nuclear Magnetic Resonance Spectrometers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1448-2014English369 Add to Cart 3 days [Need to translate] Calibration Specification for Superconducting Pulsed Fourier Transform Nuclear Magnetic Resonance Spectrometers Valid JJF 1448-2014

PDF similar to JJF 1448-2014


Standard similar to JJF 1448-2014

JJF 1234   JJF 1396   JJG 376   JJF 1457   JJF 1458   JJF 1444   

Basic data

Standard ID JJF 1448-2014 (JJF1448-2014)
Description (Translated English) Calibration Specification for Superconducting Pulsed Fourier Transform Nuclear Magnetic Resonance Spectrometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Classification of International Standard 17.220
Word Count Estimation 16,127
Date of Issue 2/14/2014
Date of Implementation 5/14/2014
Quoted Standard ASTM E386-90-2011
Adopted Standard ASTM E386-90(2011), NEQ
Regulation (derived from) ?AQSIQ Announcement 2014 No. 17
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard applies to 300MHz and above the superconducting pulse Fourier transform NMR spectrometer (hereinafter referred to as the instrument) calibration.

JJF 1448-2014: Calibration Specification for Superconducting Pulsed Fourier Transform Nuclear Magnetic Resonance Spectrometers


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Superconducting Pulsed Fourier Transform Nuclear Magnetic Resonance Spectrometers People's Republic of China National Metrology Technical Specifications Superconducting pulse Fourier transform NMR spectrometer Calibration Specification Issued on. 2014-02-14 2014-05-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Superconducting pulse Fourier transform NMR spectrometer calibration specifications ResonanceSp ectrometers Focal point. the National Technical Committee stoichiometric physical Drafting units. China Institute of Metrology This specification stoichiometric commissioned National Technical Committee is responsible for the physical interpretation Drafters of this specification. Zhang Wei (China Institute of Metrology) Huang Ting (China Institute of Metrology) Dai Xinhua (China Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 Chemical shift (1) 3.2 free induction decay (FID) (1) Linewidth factor 3.3 (1) 4 Overview (1) 4.1 Principle (1) 4.2-instrument (2) 5 Metrological characteristics (2) Calibration Condition 6 (2) 6.1 laboratory environment (2) 6.2 Standard substance (2) 6.3 Experimental Condition (3) 7 calibration items and calibration methods (3) 7.1 1H spectral sensitivity (3) 7.2 13C spectral sensitivity (3) 7.3 1H spectral resolution (4) 7.4 13C Spectral Resolution (4) 7.5 1H line type (4) 7.6 13C line type (4) 7.7 1H spectrum quantitative reproducibility (4) 8 calibration results (4) 9 Recalibration interval (5) Appendix A calibration record format (6) Appendix B Calibration Certificate page format (7) Appendix C instrument parameters is recommended (8) Appendix D Evaluation of Uncertainty (9)

Introduction

Part of this specification with reference to the use of international instruments ASTME386-90 (2011) High-resolution nuclear magnetic resonance (NMR) Spectroscopic characterization implement data standards [StandardPracticeforDataPresentationRelatingtoHigh- ResolutionNuclearMagneticResonance (NMR) Spectroscopy]. This specification is the first release. Superconducting pulse Fourier transform NMR spectrometer Calibration Specification

1 Scope

This instruction applies to 300MHz and above the superconducting pulse Fourier transform NMR spectrometer (hereinafter referred to as equipment) Calibration. 2. References Characterization of the implementation of standards ASTME386-90 (2011) High-resolution nuclear magnetic resonance (NMR) spectroscopy data (StandardPracticeforDataPresentationRelatingtoHigh-ResolutionNuclearMagnetic Resonance (NMR) Spectroscopy) "Handbook of Analytical Chemistry --- Seventh Volume NMR Spectroscopy" Beijing. Chemical Industry Press For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments Version) applicable to this specification.

3 terminology and units of measurement

3.1 chemical shift chemicalshift Proton magnetic field in the same or other magnetic core, which because of its different chemical environment in the molecule, and in Phenomenon of resonance at different frequencies, and whose scale commonly used to measure the reference material and the sample resonance frequency difference list Shown, denoted δ, dimensionless 1. δ = νS-νR ν instrument × 10 6 (1) Where. νS --- the resonance frequency of the sample, Hz; νR --- the resonance frequency of the reference material, Hz; ν instruments --- instrument operating frequency, Hz. 3.2 free induction decay (FID) freeiductiondecay Spin system under pulsed accept induction coil signal occurs, its intensity over time and decay. 3.3 linewidth factor linebroadeningfactor For each data point free induction decay signal is exponential weighting factor used. When the factor is equal to Zero, not weighted.

4 Overview

4.1 Principle Nuclear magnetic resonance spectroscopy, the study has some moments of nuclei in a static magnetic field and the magnetic field due to the interaction of the magnetic moment Resonance is formed by a set of split levels, appropriate action under the RF frequency, energy level transitions occur between now and the emergence of

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1448-2014_English be delivered?

Answer: Upon your order, we will start to translate JJF 1448-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1448-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1448-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.