US$879.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1392-2013: Program of Pattern Evaluation of Ambulatory Electrocardiographs Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1392-2013 | English | 879 |
Add to Cart
|
6 days [Need to translate]
|
Program of Pattern Evaluation of Ambulatory Electrocardiographs
| Valid |
JJF 1392-2013
|
PDF similar to JJF 1392-2013
Basic data Standard ID | JJF 1392-2013 (JJF1392-2013) | Description (Translated English) | Program of Pattern Evaluation of Ambulatory Electrocardiographs | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A56 | Classification of International Standard | 17.220 | Word Count Estimation | 38,330 | Quoted Standard | JJG 1042-2008; GB/T 14710-2009; GB/T 17626.2-2006; GB/T 17626.4-2008; GB/T 17626.5-2008; GB/T 17626.11-2008 | Regulation (derived from) | ?State AQSIQ Announcement 2013 No. 28; | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the following two types of dynamic (moving) pattern evaluation ECG machine: a) continuous recording, analysis of ECG and achieve full playback. Can be recorded, analysis or playback after recording by an independent workstation st |
JJF 1392-2013: Program of Pattern Evaluation of Ambulatory Electrocardiographs---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Ambulatory Electrocardiographs
People's Republic of China National Metrology Technical Specifications
Dynamic (movable) ECG machine
Type Evaluation Outline
Issued on. 2013-02-16
2013-05-16 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Dynamic (movable) ECG machine
Type Evaluation Outline
hs
Focal point. the National Radio Technical Commission metering
Main drafting unit. Beijing Institute of Metrology detection
Participated in the drafting. General Logistics Department of Health Drug and Instrument Control
China Institute of Metrology
This specification commissioned the National Radio Technical Commission responsible for the interpretation of measurement
The main drafters of this specification.
Wen Cummins (Beijing Institute of Metrology detection)
Zhangjian Ling (Beijing Institute of Metrology detection)
Drafters participate.
Xue Li Yong (General Logistics Department of the Ministry of Health Drug and Instrument Control)
He Zhao (China Institute of Metrology)
Gao Yang (Beijing Institute of Metrology detection)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 legal management requirements (2)
4.1 Units of measurement requirements (2)
4.2 legal metrology requirements for marking and identification of measuring instruments (2)
4.3 Other requirements (2)
5 measurement requirements (2)
5.1 Maximum input range (2)
5.2 tracings minimum sensitivity threshold (2)
5.3 Resistance polarization voltage (2)
5.4 Input impedance (2)
5.5 Sensitivity error (2)
5.6 sensitivity stability (2)
5.7 Calibration voltage (applies only to analog memory device to be examined) (2)
5.8 Frequency Response (3)
5.9 Overshoot (3)
Hysteresis 5.10 (3)
5.11 timing error (only applicable to the event insertion means to be examined on a recorder) (3)
5.12 hard copy (printout or photo) tracings speed error (3)
Interference between 5.13 (3)
5.14 common mode rejection ratio (3)
5.15 system noise level (3)
5.16 compliance and pacing pulse detection capability (3)
6 General Requirements (3)
6.1 appearance and work of (3)
6.2 Climate requirements (4)
6.3 Mechanical environmental requirements (4)
6.4 Power adaptability (4)
6.5 EMC requirements (4)
7 type evaluation item list (4)
8 type evaluation test methods and conditions (5)
8.1 Legal Requirements Management (5)
8.2 metrological requirements (5)
8.3, and appearance check work (15)
8.4 Climate Environmental Testing (15)
8.5 Mechanical environmental testing (16)
8.6 Power adaptability test (16)
8.7 Electromagnetic compatibility tests (17)
Type 9 Judgment principle results (25)
Appendix A dynamic (movable) ECG machine type evaluation original record format (26)
Introduction
This outline is dynamic (movable) ECG machine type evaluation basis.
The preparation of the outline to JJG1042-2008 "dynamic (movable) ECG machine", GB/T 14710-2009
"Medical electrical environmental requirements and test methods", GB/T 17626.2-2006 "Electromagnetic compatibility - Testing and measurement techniques
Electrostatic discharge immunity test ", GB/T 17626.4-2008" Electromagnetic compatibility - Testing and measurement techniques - Electrical fast
Transient burst immunity test ", GB/T 17626.5-2008" Electromagnetic compatibility - Testing and measurement techniques - Surge
(Impact) immunity test "and GB/T 17626.11-2008" electromagnetic compatibility test and measurement technology voltage sags
Drop, short interruptions and voltage variations immunity tests "basis.
This outline is the first release.
Dynamic (movable) ECG machine
Type Evaluation Outline
1 Scope
This type of evaluation outline for the following two types of dynamic pattern evaluation (removable) ECG machine.
a) continuous recording, analysis and electrocardiogram achieve full playback. It may be recorded after storage back to the stand-alone workstation
Caving or recorded, analyzed simultaneously.
b) continuous analysis but only a part of the record, does not provide full playback.
2. References
This outline references the following documents.
JJG1042-2008 dynamic (movable) ECG machine
GB/T 14710-2009 medical electrical environmental requirements and test methods
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity
test
GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test
GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage
Variations immunity tests
These documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents
Members, release date only applies to this outline, however, encourage the parties according to research whether this outline agreement
Use the latest versions of these files. For undated references, the latest edition (including all amendments
) Apply to this syllabus.
3 Overview
Dynamic (movable) ECG machine capable of continuously 24h or longer, three-channel recording in the patient's natural state
Or multi-channel ECG signal by means of a computer for display, analysis and processing, find all kinds of arrhythmia and ST events
Segment abnormalities, provide an important basis for clinical diagnosis and treatment.
Dynamic (movable) ECG machine is usually divided into two types.
a) for continuous recording and analytical dynamic (movable) ECG machine
1) Conventional dynamic (movable) ECG machine, the first recorded ECG signal, and then dividing by the individual workstation
Analysis process;
2) real-time dynamic (movable) ECG, recorded and analyzed simultaneously.
b) Continuous analysis but some recordable dynamic (movable) ECG machine
1) In the course of the entire ECG only on important events or specific ECG recording;
2) In the whole course of the real ECG recording ECG, but only generates time and amplitude compression formats
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1392-2013_English be delivered?Answer: Upon your order, we will start to translate JJF 1392-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1392-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1392-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|