US$669.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1309-2011: Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement Status: Valid JJF 1309: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1309-2011 | English | 669 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement
| Valid |
JJF 1309-2011
|
JJF 1309-1990 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
O.T.N. of Atomic Time Scale Primary Standard
| Obsolete |
JJF 1309-1990
|
PDF similar to JJF 1309-2011
Basic data Standard ID | JJF 1309-2011 (JJF1309-2011) | Description (Translated English) | Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A54 | Classification of International Standard | 17.200 | Word Count Estimation | 29,231 | Date of Issue | 2011-09-14 | Date of Implementation | 2011-12-14 | Quoted Standard | JJG 617-1996; GB/T 16839.2-1997; JB/T 8622-1997; JB/T 8623-1997 | Regulation (derived from) | AQSIQ Announcement No. 134 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the calibration temperature calibration. Temperature Calibrator can be connected with RTD or thermocouple to measure the temperature, you can also simulate thermal resistance, thermocouple, or the output of the process signal calibration temperature secondary instrument. Temperature Calibrator (hereinafter referred to as calibrator) can be a part of the multi-function calibrator. |
JJF 1309-2011: Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement
People's Republic of China National Metrology Technical Specifications
Temperature Calibrator calibration specifications
Issued on. 2011-09-14
2011-12-14 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Temperature Calibrator calibration specifications
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 14, 2011, and from
From December 14, 2011 into effect.
Focal point. the National Technical Committee of temperature measurement
Main drafting unit. Shanghai Institute of Measurement and Testing
Participated in the drafting unit. China Testing Technology Research Institute
Dalian metrological verification tests
Beijing Const Instrument Technology Co., Ltd.
Shandong Province Institute of Metrology
Hebei Academy of Supervision and Testing
This specification commissioned the National Technical Committee is responsible for interpretation of temperature measurement
The main drafters of this specification.
Zhu Jialiang (Shanghai Institute of Measurement and Testing)
Cui Ling Yan (Shanghai Institute of Measurement and Testing)
Drafters participate.
EDUCATION JOURNAL (China Testing Technology Research Institute)
Li Ying (Dalian metrological verification tests)
Liu Baoqi (Beijing Const Instruments Technology Co., Ltd.)
Sun Shulan (Shandong Province Institute of Metrology)
Liu Hongyan (Hebei Supervision and Testing Institute)
table of Contents
1 Scope (1)
2. References (1)
3 Overview (1)
4 Metrological characteristics (1)
4.1 indication error (1)
4.2 output error (2)
4.3 analog RTD excitation current effective range (2)
The minimum temperature in steps of 4.4 output (2)
Calibration Condition 5 (2)
5.1 standard devices and other equipment (2)
Environmental conditions 5.2 (3)
5.3 Power (3)
6 calibration items and calibration methods (3)
6.1 calibration items (3)
6.2 Calibration method (3)
6.3 Data Processing principle (7)
Expression 7 Calibration results (7)
8 Recalibration interval (8)
A wire compensation calibration method Appendix (9)
Appendix B Calibration temperature calibrator original record format (13)
Appendix C Temperature Calibrator Error in Measurement of Uncertainty Evaluation (15)
Appendix D Temperature Calibrator output error measurement results Uncertainty Evaluation (18)
Appendix E thermal resistance of the differential resistance and thermocouple Seebeck coefficient (21)
Appendix F Calibration Certificate-page format (23)
Temperature Calibrator calibration specifications
1 Scope
This standard applies to the calibration temperature calibration. Temperature Calibrator can be connected with RTD or thermocouple to measure the temperature
Degree, can also simulate RTD or thermocouple output process signals to calibrate the temperature of the secondary instrument.
Temperature Calibrator (hereinafter referred to as the calibrator) can be part of the multi-function calibrator.
2. References
This specification references the following documents.
JJG617-1996 Digital Temperature Indicators and Controllers
GB/T 16839.2-1997 Thermocouples - Part 2. Tolerances
JB/T 8622-1997 industrial platinum RTD Technical conditions and indexing table
JB/T 8623-1997 industrial copper heat resistance Technical conditions and indexing table
For dated references, only the edition date of application of this specification, cited documents without a date,
The latest version (including any amendments) applies to this specification.
3 Overview
Calibrator has two functions and output measurements, temperature measuring instruments belonging to the multifunction measuring instruments. Calibrator
It can be measured and simulated thermal resistance type usually Pt100, Pt500, Pt1000, Cu50, Cu100 and so on; measuring
Type thermocouple simulation and usually B, S, R, K, N, E, J, T, etc; DC analog signal output from the process
Current is 4mA ~ 20mA or dc voltage of 1V ~ 5V and the like.
When the calibrator is set in the measurement mode, you can connect with RTD or thermocouple to measure the temperature, the equivalent of a number
Word temperature indicator. Calibrator when connecting thermocouples to measure temperature, usually having a built-in reference junction temperature compensation function automatically
Can, it can not directly connected with the external thermocouple cold junction compensator. Some calibrator manual switching compensation.
When you set the calibrator output state can simulate a variety of thermal resistance, thermocouple temperature transmitter output and the corresponding
Standard electrical signal to calibrate the temperature of the secondary instrument. Usually in the form of the numeric keypad to set the analog temperature value, can also be used
Increasing or decreasing the minimum temperature in a stepwise manner to apply to analog temperature secondary instrument calibration. Calibrator thermoelectric simulation
Dual output, usually a reference junction temperature automatic compensation function, the output was simulated thermocouple reference junction temperature
Potential output terminal temperatures. Some calibrator manual switching compensation.
RTD and thermocouple simulation, correspondence and the corresponding relationship between temperature and resistance temperature and potential are to follow
GB/T 16839.2-1997, JB/T 8622-1997, JB/T 8623-1997 standards.
4 Metrological characteristics
4.1 Indication error
Calibrator set in the measurement state, as the use of digital temperature indicator, which shows the difference between the input value and the standard value for the
Indication error calibrator. The maximum permissible error indication will usually not exceed ± (0.01 ~ 0.6) ℃.
|