HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (7 Jun 2025)

English JJF 1175-2021 PDF (JJF 1175-2007: Older version)

Search result: JJF 1175-2021 (JJF 1175-2007 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1175-2021English489 Add to Cart 4 days [Need to translate] Calibration Specification for Test Sieves Valid JJF 1175-2021
JJF 1175-2007English799 Add to Cart 4 days [Need to translate] Calibration Specification for Test Sieves Obsolete JJF 1175-2007


BASIC DATA
Standard ID JJF 1175-2021 (JJF1175-2021)
Description (Translated English) Calibration Specification for Test Sieves
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A28
Classification of International Standard 19.120
Word Count Estimation 22,274
Date of Issue 2021-12-08
Date of Implementation 2022-06-08
Issuing agency(ies) State Administration for Market Regulation
Summary This standard is applicable to the calibration of wire mesh test sieves with a mesh size of (0.020~125) mm and metal perforated plate test sieves with a mesh size of (1~125) mm.


JJF 1175-2021: Specification for Calibration of Test Sieves National Metrology Technical Specifications of the People's Republic of China Test Sieve Calibration Specifications Released on 2021-12-08 2022-06-08 Implementation Released by the State Administration for Market Regulation Test Sieve Calibration Specifications Replace JJF 1175-2007 Responsible unit: National Technical Committee of Geometric Engineering Parameter Metrology Main drafting unit: Heilongjiang Metrology Verification and Testing Research Institute China Machinery Productivity Promotion Center Zhejiang Institute of Metrology Participating in the drafting unit: Xinxiang Bashan Aeronautical Materials Co:, Ltd: Liaoning Institute of Metrology Fujian Institute of Metrology This specification entrusts the National Geometric Engineering Parameter Metrology Technical Committee to be responsible for interpretation The main drafters of this specification: Zhang Haibo (Heilongjiang Provincial Institute of Metrology and Testing) Han Zhengyang (Heilongjiang Provincial Institute of Metrology and Testing) Hou Changge (China Machinery Productivity Promotion Center) Ye Xin (Zhejiang Institute of Metrology) Participating drafters: Bai Qianyang (Xinxiang Bashan Aviation Materials Co:, Ltd:) Liu Na (Liaoning Institute of Metrology) Chaoyang (Fujian Institute of Metrology) Table of contents Introduction (Ⅱ) 1 range(1) 2 References(1) 3 Overview(1) 4 Metrological characteristics(2) 4:1 Wire woven mesh test sieve mesh size (2) 4:2 Mesh hole size of metal perforated plate test sieve (2) 5 Calibration equipment and ambient conditions(2) 6 Calibration Items and Calibration Methods(3) 6:1 Wire woven mesh test sieve mesh size (3) 6:2 Mesh hole size of metal perforated plate test sieve(3) 7 Expression of Calibration Results(4) 8 Recalibration interval(4) Appendix A Test sieve measurement characteristic index (5) Appendix B Uncertainty Evaluation of Measuring Results of Mesh Mesh Size of Wire Woven Mesh Test Sieve (11) Appendix C Uncertainty Evaluation of Measuring Results of Sieve Size of Metal Perforated Plate Test Sieve (14) Appendix D Calibration Certificate Contents(16) introduction This specification is based on JJF 1071-2010 "National Measurement and Calibration Specification Writing Rules", JJF 1001-2011 "General Measurement Terms and Definitions", JJF 1059:1-2012 "Assessment and Expression of Measurement Uncertainty" as the basis and basis revised: Compared with JJF 1175-2007 "Calibration Specifications for Test Sieves", except for editorial modifications, the main technical changes as follows: ---Introduction added; ---Deleted the "sieve hole size between the maximum size (w X) and the number of sieve holes between the middle size (w Z) Quantity" calibration item; --- Deleted the "Basic Size Determination" calibration item; --- Modified the calibration method of "maximum size of sieve hole" and "average size of sieve hole"; ---Modified the "Uncertainty assessment of the measurement results of the mesh size of the wire mesh test sieve"; --- Move the metrological characteristics of the test sieve to Appendix A; ---Delete the technical requirement "Intermediate deviation in the mesh size deviation of the wire mesh test sieve"; --- Added the technical requirements of "Maximum standard deviation of wire mesh test sieve mesh size": The previous releases of this specification are as follows: ---JJF 1175-2007: Test Sieve Calibration Specifications 1 Scope This specification is applicable to the wire mesh test sieve with the sieve size of (0:020~125) mm and the sieve size of (1~125)mm metal perforated plate test sieve calibration: 2 References This specification references the following documents: GB/T 5329-2003 Test sieves and sieving test terms GB/T 6003:1-2012 Test sieve technical requirements and inspection Part 1: Metal wire mesh test sieve GB/T 6003:2-2012 Test sieve technical requirements and inspection Part 2: Metal perforated plate test sieve GB/T 6005-2008 Basic principles of test sieve wire mesh, perforated plate and electroformed sheet size For dated references, only the dated version applies to this specification; for undated references document, its latest version (including all amendments) applies to this specification: 3 Overview Test sieves are mainly used for particle size analysis and sieving tests on granular materials: Wire woven mesh test sieve is shown in Figure 1 The metal perforated plate test sieve is shown in Figure 2: The arrangement of the test sieve holes is shown in Figure 3, Figure 4 and Figure 5: Fig:1 Schematic diagram of wire woven mesh test sieve 1-wire mesh; 2-main part; 3-base; 4-2 and 3 form a screen frame Figure 2 Schematic diagram of metal perforated plate test sieve 1-metal perforated plate; 2-main part; 3-base; 4-2 and 3 form a screen frame ......


JJF 1175-2007 Calibration Specification for Test Sieves People's Republic of China National Metrology Technical Specifications Test sieve calibration specifications Posted 2007-02-28 2007-05-28 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Test sieve calibration specifications CalibrationSp This specification by the State Administration of Quality Supervision, Inspection and Quarantine, 2007 February 28 ratification and From May 28, 2007 into effect. NFP. National Engineering Geometrical Parameters Measurement Technology Committee Main drafting unit. Heilongjiang Provincial Academy of verification test Shaanxi Provincial Institute of Metrology Participated in the drafting unit. Hebei Institute of Metrology Henan Institute of Measurement and Testing Measurement Science and Technology Institute in Fujian Province This specification shall be interpreted by the focal point The main drafters of this specification. Zhang Liping (Heilongjiang Provincial Academy of verification test) Zhang Lei (Shaanxi Provincial Institute of Metrology) Liang Yuhong (Heilongjiang Provincial Academy of verification test) Drafters participate. Wang Shaoping (Hebei Institute of Metrology) Gu Xiaojie (Henan Institute of Measurement and Testing) Liao Yi water (Fujian Institute of Measurement Science Technology) Xiaoliang (Heilongjiang Provincial Academy of verification test) table of Contents 1 Scope (1) 2. Referenced Documents (1) 3 Terms and Definitions (1) Sieving 3.1 (1) 3.2 sieve size analysis (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 Test sieves of metal wire cloth (1) 5.2 Test sieves of perforated metal plate (7) 6 calibration conditions (9) Environmental conditions 6.1 (9) 6.2 be corrected test sieve should have the conditions (9) 6.3 calibration equipment (9) 7 calibration items and calibration methods (9) 7.1 woven wire mesh calibration test pore size (9) 7.2 perforated metal plate calibration test sieve mesh size (10) 8 calibration results expression (10) 9 Recalibration interval (10) Uncertainty Analysis Appendix A woven wire mesh sieve size sieve test measurements (11) Appendix B Test sieves of perforated metal mesh size measurement uncertainty analysis (13) Appendix C calibration certificate contents (15) Test sieve calibration specifications 1 Scope This instruction applies to size (0.020 ~ 125) mm wire braid, (1 ~ 125) mm metal Perforated plate test sieve calibration. 2 Citations This specification references the following documents. JJF 1001-1998 common measurement terms and definitions JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement JJF 1094-2002 measuring instrument characteristics assessed technical specifications JJF 1130-2005 geometric measurement equipment calibration Uncertainty Evaluation Guide GB/T 5329-2003 term test sieves and screening tests GB/T 6003.1-1997 Test sieves of metal wire cloth GB/T 6003.2-1997 Test sieves of perforated metal plate Basic dimensions GB/T 6005-1997 Test sieves - Metal wire cloth, perforated plate and electroformed sheet mesh ISO 2395-1990 term test sieves and screening tests When using this specification it should be noted that using the currently valid version of the documents cited. 3 Terms and Definitions 3.1 sieve (sieving) With one or more sieves having different particle sizes of discrete particles size by size material separation process. 3.2 sieve size analysis (sizeanalysisbysieving) By sieving the sample was divided into different levels of granularity and report the results. 4 Overview Test sieve is used for screening particulate material having a particle size sieve analysis. It is widely used in geological exploration, metallurgy, Chemical, pharmaceutical, building materials, abrasive and other industries as well as research institutes particle size analysis and screening tests. Complete test sieve and covered by a number of different mesh size sieve, splice tray, as shown in Fig. metal Wire cloth test sieves, test sieve perforated metal mesh surface or mesh arrangement shown in Figure 2, Figure 3 and Figure 4. 5 Metrological characteristics 5.1 Test sieves of metal wire cloth 5.1.1 The maximum mesh size (ω X) The maximum mesh size of the deviation in Table 1. ......

Similar standards: GB/T 6003.1   GB/T 21649.2   GB/T 19077   JJG 1175