US$759.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZ24843-2009: Technical specification of 1000 kV single phase oil-immersed auto-transformer Status: Obsolete
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/Z 24843-2009 | English | 759 |
Add to Cart
|
4 days [Need to translate]
|
Technical specification of 1000 kV single phase oil-immersed auto-transformer
| Obsolete |
GB/Z 24843-2009
|
PDF similar to GBZ24843-2009
Basic data | Standard ID | GB/Z 24843-2009 (GB/Z24843-2009) | | Description (Translated English) | Technical specification of 1000 kV single phase oil-immersed auto-transformer | | Sector / Industry | National Standard | | Classification of Chinese Standard | K41 | | Classification of International Standard | 29.240 | | Word Count Estimation | 19,156 | | Date of Issue | 2009-11-30 | | Date of Implementation | 2010-05-01 | | Quoted Standard | GB 1094.1; GB 1094.2; GB 1094.3-2003; GB/T 1094.4; GB 1094.5; GB/T 1094.7; GB/T 1094.10; GB 2536; GB/T 5273; GB/T 2900.15 | | Regulation (derived from) | ?National Standard Approval Announcement 2009 No.14 (Total No.154) | | Issuing agency(ies) | Ministry of Health of the People's Republic of China | | Summary | This standard specifies the performance parameters of 1 000 kV single-phase oil-immersed power transformers auto, structural requirements, tests and signs, packaging and transportation requirements. The technical guidance document applies to 1 000 kV class, rated capacity of 1 000 MVA and 1 500 MVA auto single-phase oil-immersed power transformers. |
GBZ24843-2009: Technical specification of 1000 kV single phase oil-immersed auto-transformer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specification of 1000 kV single phase oil-immersed auto-transformer
ICS 29.240
K41
People's Republic of China national standardization of technical guidance documents
1000 犽 犞 single-phase oil-immersed self-transformers
specifications
Posted.2009-11-30
2010-05-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Conditions of use 2
5 performance parameters 3
6 structural requirements 5
7 Test 6
8 logo, packaging and shipping 10
Appendix A (informative) Typical 1000kV single-phase oil-immersed autotransformer structure principle introduction 11
Appendix B (informative) high-voltage line long-term induced voltage test (ACLD) and medium-voltage line short-term induction
Pressure Test (ACSD) Note 12
Appendix C (informative) Winding rated insulation level of all countries 14
Foreword
Appendix A, Appendix B, Appendix C of this guidance document are informative appendices.
This Guidance Document is proposed by China Electricity Council.
This Guidance Document is administered by China Electricity Council.
The guidance of technical documents by the UHV AC Transmission Standardization Technical Committee, China Electric Power Research Institute responsible for the interpretation.
The guidance of technical documents drafted by. State Grid Corporation, China Electric Power Research Institute.
The guidance of technical documents Participated in the drafting of. State Grid Electric Power Research Institute, Shenyang Transformer Research Institute, TBEA Shenyang Transformer
Group Co., Ltd., Baoding Tianwei change Electric Co., Ltd., Xi'an XD transformer limited liability company.
The main drafters of this Guidance Document are Shubin Biao, Li Guangfan, Zhu Yinghao, Liu Zehong, Fu Xiian, Wang Shaowu, Ling Yong, Hu Huiru,
Wang Mengyun, Wanda, Wang Xiaoning, Li Jinzhong.
Drafters of this technical note. Zhong Juntao, Zhang Xi Le, Chuan Chuan Long, Li Bo, Wu Zhirong, Sun Shubo, Liu Dongsheng, Xie Qingfeng,
Zhang Shuqi, Wang Ninghua, Zhao Zhigang, Guo Huihao.
Introduction
The guidance of technical documents is combined with our 1000kV UHV AC transmission equipment manufacturing, construction and operation experience of
Based on the development.
The development of the guidance of technical documents, to regulate 1000kV single-phase oil-immersed power transformer performance parameters, structural requirements, test
And signs, packaging and transportation to provide technical guidance, to ensure that 1000kV single-phase oil-immersed self-transformers safe and reliable operation
Line is of great significance.
1000 犽 犞 single-phase oil-immersed self-transformers
specifications
1 Scope
This guidance provides technical parameters of 1000kV single-phase oil-immersed self-transformers performance parameters, structural requirements, test and standard
Zhi, packaging and transportation requirements.
The guidance of technical documents for 1000kV level, rated capacity of 1000MVA and 1500MVA single-phase oil-immersed auto
Power transformers.
2 Normative references
The following documents contain provisions which, through reference in this Guidance Document, become the provisions of this Guidance Note document. All dated
Reference documents, all subsequent amendments (not including errata content), or revisions do not apply to this guidance document, however, drums
Recipients of the agreement based on this guidance document are encouraged to study whether the latest versions of these documents are applicable. All undated references
The latest version of this document applies to this guidance document.
GB 1094.1 Power Transformers Part 1. General (GB 1094.1-1996, eqv IEC 60076-1..1993)
GB 1094.2 Power Transformer Part 2. Temperature Rise (GB 1094.2-1996, eqv IEC 60076-2..1993)
GB 1094.3-2003 Power transformers - Part 3. Insulation level, insulation test and external insulation air gap (IEC 60076-3.
2000, MOD)
GB/T 1094.4 Power Transformers - Part 4. Lightning Impulse Test and Operational Impact Test Guidelines for Power Transformers and Reactors
Then (GB/T 1094.4-2005, IEC 60076-4..2002, MOD)
GB 1094.5 power transformers Part 5. the ability to withstand short circuits (GB 1094.5-2008, IEC 60076-5..2006,
MOD)
GB/T 1094.7 Power Transformers Part 7. Oil-immersed Power Transformer Load Guidelines (GB/T 1094.7-2008, IEC
60076-7..2005, MOD)
GB/T 1094.10 Power transformers Part 10. Determination of sound level (GB/T 1094.10-2003, IEC 60076-10..2001,
MOD)
GB 2536 transformer oil (GB 2536-1990, eqv IEC 60296. 1982)
GB/T 5273 transformers, high voltage electrical wiring and casing (GB/T 5273-1985, neqIEC 60518. 1975)
GB/T 2900.15 Electrotechnical terminology transformers, transformers, voltage regulators and reactors (GB/T 2900.15-1997, neqIEC
60050 (421)..1990, IEC 60050 (321). 1986)
3 Terms and definitions
GB 1094.1 and GB/T 2900.15 established and the following terms and definitions apply to the guidance of technical documents.
3.1
When the 1000kV single-phase oil-immersed self-coupling power transformer transformer with the body part of the regulator and the partial compensation box layout transformer
The body part.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ24843-2009_English be delivered?Answer: Upon your order, we will start to translate GBZ24843-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GBZ24843-2009_English with my colleagues?Answer: Yes. The purchased PDF of GBZ24843-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|