|
US$439.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24843-2018: Technical specification of 1 000 kV single phase oil-immersed auto-transformer Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24843-2018 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Technical specification of 1 000 kV single phase oil-immersed auto-transformer
| Valid |
GB/T 24843-2018
|
PDF similar to GB/T 24843-2018
Basic data | Standard ID | GB/T 24843-2018 (GB/T24843-2018) | | Description (Translated English) | Technical specification of 1 000 kV single phase oil-immersed auto-transformer | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K41 | | Classification of International Standard | 29.240 | | Word Count Estimation | 22,241 | | Date of Issue | 2018-07-13 | | Date of Implementation | 2019-02-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 24843-2018: Technical specification of 1 000 kV single phase oil-immersed auto-transformer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specification of 1 000 kV single phaseoil-immersed auto-transformer
ICS 29.240
K41
National Standards of People's Republic of China
Replace GB /Z 24843-2009
1000kV single-phase oil immersed autotransformer power transformer
specifications
Published on.2018-07-13
Implementation of.2019-02-01
State Market Supervisory Administration
China National Standardization Administration issued
Content
Foreword III
1 Scope 1
2 Normative references 1
3 terms and definitions, symbol 1
4 Conditions of use 2
5 performance parameters 3
6 Structure and group component requirements 6
7 test 8
8 Marking, packaging and shipping 12
Appendix A (informative) High-voltage line end long-term induced voltage test (ACLD) and medium-voltage line end short-time induction withstand voltage test (ACSD)
Description 13
Appendix B (informative) Comparison of rated insulation levels of UHV transformer windings in various countries 15
Appendix C (informative) Introduction to the typical 1000kV single-phase oil-immersed autotransformer wiring principle 16
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB /Z 24843-2009 "1000kV single-phase oil-immersed self-coupling power transformer technical specification". With GB /Z 24843-
The main technical changes in.2009 are as follows.
--- Added some terms and definitions, including disintegration transport (3.1.7), on-site assembly (3.1.8);
--- Updated the pollution level requirements (see 4.1.8, 4.1.8 of the.2009 edition);
--- Increased on-load tap-changing range (see Table 1);
--- Increased the no-load loss and deviation requirements of 1500MVA UHV transformers (see 5.4.1);
--- Increased requirements for on-load tap-changers (see 6.4);
--- Increased casing structure requirements (see 6.6.5);
--- Increased the test program for dissolved gases in oil (see 7.2.1);
--- Increase the understanding of body transport and on-site assembly and other related content (see 6.1, 8.1.6);
--- For the high-voltage line end long-term induced voltage test (ACLD) and medium-voltage line end short-time induction withstand voltage test (ACSD)
The description was further clarified (see Appendix A);
--- Added schematic diagram of constant flux compensation [see Appendix C, Figure C.1b)].
This standard was proposed by the China Electricity Council.
This standard is under the jurisdiction of the National UHV AC Transmission Standardization Technical Committee (SAC/TC569).
This standard was drafted. State Grid Corporation, China Electric Power Research Institute Co., Ltd., State Grid Electric Power Research Institute, Shenyang Transformer
Research Institute, TBEA Shenyang Transformer Group Co., Ltd., Baoding Tianwei Baobian Electric Co., Ltd., Xi'an Xidian Transformer Co., Ltd.
Any company.
The main drafters of this standard. Shu Yinyi, Li Guangfan, Zhu Yinghao, Liu Zehong, Fu Xiian, Wang Shaowu, Ling Wei, Hu Huiran, Wang Mengyun, Wanda,
Wang Xiaoning, Li Jinzhong, Zhong Juntao, Zhang Xile, Ruan Chuanlong, Li Bo, Wu Zhirong, Sun Shubo, Liu Dongsheng, Xie Qingfeng, Zhang Shuqi, Wang Ninghua, Zhao Zhigang,
Guo Huihao.
The previous versions of the standards replaced by this standard are.
---GB /Z 24843-2009.
1000kV single-phase oil immersed autotransformer power transformer
specifications
1 Scope
This standard specifies the performance parameters, structural requirements, tests and signs, packaging and transportation of 1000kV single-phase oil-immersed autotransformer power transformers.
Requirements for losing and other aspects.
This standard applies to single-phase oil immersed auto-coupling power transformers of 1000kV class with rated capacity of 1000MVA and 1500MVA.
Pressure device.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1094 (all parts) Power Transformers
GB/T 1094.1 Power transformers - Part 1. General
GB/T 1094.2 Power transformers - Part 2. Temperature rises of liquid immersed transformers
GB/T 1094.3-2003 Part 3. Insulation level, insulation test and external insulation air gap
GB/T 1094.4 Power transformers - Part 4. Lightning impulse test and operational impulse test for power transformers and reactors
Guidelines
GB/T 1094.5 Power transformers - Part 5. Ability to withstand shorts
GB/T 1094.7 Power transformers - Part 7. Load guides for oil-immersed power transformers
GB/T 1094.10 Power transformers - Part 10. Sound level determination
GB/T 2424.25 Environmental testing of electrical and electronic products - Part 3. Test guides
GB 2536 Unused mineral insulating oil for electrical fluid transformers and switches
GB/T 2900.15 Electrotechnical terminology transformers, transformers, voltage regulators and reactors
GB/T 5273-2016 High-voltage electrical terminal size standardization
GB/T 10230.1 Tap-changers - Part 1. Performance requirements and test methods
GB 50994 Industrial Enterprise Electrical Equipment Seismic Evaluation Standard
IEC 60296.2012 Unused mineral insulating oil for liquid transformers and switchgear for electricians (Fluidsforelectro-
technicalapplications-Unusedmineralinsulatingoilsfortransformersandswitchgear)
3 terms and definitions, symbols
3.1 Terms and definitions
The following terms and definitions as defined in GB/T 1094.1 and GB/T 2900.15 apply to this document.
3.1.1
Main transformer mainpartoftransformer
When the 1000kV single-phase oil-immersed self-coupling power transformer adopts the transformer body part and the voltage regulation compensation part, the transformer is arranged.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24843-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 24843-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24843-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24843-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|