GB/T 6920-1986 PDF English
US$70.00 · In stock · Download in 9 secondsGB/T 6920-1986: Water quality. Determination of pH value. Glass electrode method Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
GB/T 6920-1986 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Water quality. Determination of pH value. Glass electrode method
| |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB/T 6920-1986
GB/T 6920-1986: Water quality. Determination of pH value. Glass electrode method---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT6920-1986
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
UDC 663.6.543.06
GB 6920-86
Water quality -- Determination of pH value
-- Glass electrode method
Issued on. OCTOBER 10, 1986
Implemented on. MARCH 1, 1987
Approved by. State Environmental Protection Administration
Table of Contents
1 Scope of application... 3
2 Definitions... 3
3 Principle... 4
4 Reagents... 4
5 Instruments... 7
6 Sample preservation... 7
7 Steps... 7
8 Degree of precision (see Table 3)... 8
9 Annotations... 8
10 Test Report... 9
Additional description... 10
UDC 663.6.543.06
Water quality -- Determination of pH value
-- Glass electrode method
GB 6920-86
1 Scope of application
1.1 This method is applicable to the determination of the pH value of drinking water, surface
water and industrial wastewater.
1.2 The color, turbidity, colloidal substance, oxidizing agent, reducing agent and high
salinity of water do not interfere with the determination; however, in the strong acidic
solution with pH < 1, there is so-called "acid error", which can be determined according to
the acidity; in the alkaline solution with pH >10, due to the existence of a large amount of
sodium ions, the error is generated; therefore, the reading is relatively low, which is
commonly referred to as "sodium error". For the methods of eliminating the "sodium error",
in addition to use the specially-made electrode of “low sodium error”, it can also adopt the
standard buffer solution which is similar to the pH value of the solution under test, in order
to calibrate the instrument.
The temperature can affect the electric potential of the electrodes and the ionization
balance of the water. It shall be noted that the compensation device of the adjusting
instrument should be consistent with the temperature of the solution, and the temperature
error of the standard buffer solution between the sample to be measured and the calibrating
instrument should be within ± 1°C.
2 Definitions 1
The pH is defined from the operation. For solution X, it should measure the galvanic cell’s.
reference electrode|KCl concentrated solution|| solution X |H2| Pt
electromotive force EX. Replace the solution X, whose pH(X) is unknown, into the standard
1 This definition is cited from p.151 of GB 3100-3102-82 Quantities and units.
pH solution S, and measure the battery’s electromotive force ES, then,
pH(X)=pH (S) + (Es - Ex) F / (RTln10)
Therefore, the defined pH is the dimensionless quantity.
pH has no theoretical significance. the definition is the practical definition. However, within
the limited range of the dilute aqueous solution whose amount-of-substance concentration
is less than 0.1mol·dm3, when it is neither strong acidity nor the strong alkalinity (2 < pH <
12), then it has the followings according to the definition.
pH=-log10[c(H+)y / (mol·dm3)] ± 0.02
In the formula, c(H+) represents the amount-of-substance concentration of the hydrogen
ion (H+). y represents the activity coefficient of the typical 1-1-valence electrolyte in the
solution.
3 Principle
The pH value is obtained by measuring the electromotive force of the battery. This battery
is usually composed of that the saturated calomel electrode is acted as the reference
electrode AND the glass electrode is acted as the indicator electrode. At the temperature
of 25°C, if the solution changes 1 pH unit, the change of the potential difference will be
59.16 mV.
4 Reagents
4.1 Preparation method of the standard buffer solution (abbreviated as standard solution)
4.1.1 Mass of the reagent and distilled water
4.1.2 When measuring the pH, according to the three possible conditions -- the water
sample can present to acidity, neutrality and alkalinity -- the following three standard
2 The unit of electrical conductance is Siemens which is denoted by the symbol of "S". 1S = 1Ω-1.
solutions are often prepared.
4.1.2.1 pH standard solution A (pH 4.008, 25°C)
Weigh and take 10.12g of potassium acid phthalate (KHC8H4O4) which has been dried for
2-3 hours at 110~130°C. Dissolve it in the water AND dilute it to 1L in volumetric flask.
4.3 Preservation of the standard solution
4.3.1 Standard solution shall be sealed in the polyethylene bottle or hard glass bottle for
preservation.
4.3.2 Under the condition of room temperature, the standard solution is generally stored
for 1~2 months. When finding the phenomenon of turbidity, moldiness and sedimentation,
it should not be used anymore.
4.4 The pH value of the standard solution can vary slightly with the changes of the
temperature. The pH (S) values of certain common standard solutions are shown in Table
2.
5 Instruments
5.1 Acidity meter or ion concentration meter. The instrument for the routine test should
accurate to 0.1pH unit. The pH range is from 0 to 14.If there is special requirement, the
instrument with higher precision shall be used.
6 Sample preservation
It is best to conduct the site measurement. Otherwise, the samples should be kept at the
0~4°C after the sampling, and they should be measured within 6 hours after the sampling.
7 Steps
7.1 Instrument calibration. The operating procedure shall be carried out according to the
operation instruction of the instrument. Firstly, adjust the water sample and the standard
solution to the same temperature; record the measurement temperature; and adjust the
temperature-compensation knob of the instrument to this temperature.
7.2 Sample determination
When determine the sample, it should carefully rinse the electrode with distilled water, and
then rinse it with the water sample, then immerse the electrode in the sample. Shake it
carefully or stir it to make it uniform. Keep it in still standing. Record the pH value when the
reading is stable.
8 Degree of precision (see Table 3)
Repeatability 5 Reproducibility 6
9 Annotations
9.1 The glass electrode should be immersed in the distilled water for more than 24 hours
before use.
9.2 When measuring the pH, the bulb of the glass electrode shall be completely immersed
in the solution, and it should allow it to be slightly higher than the ceramic core end of the
calomel electrode, in order not to bump the cup when stirring.
9.4 The liquid level of the saturated potassium chloride solution in the calomel electrode
must be higher than the mercury body. It should have little potassium chloride crystal at
the room temperature, in order to ensure the saturation of the potassium chloride solution,
however, it is important to note that the potassium chloride crystal should not be too much,
in order to prevent from blocking the access of the solution to be tested.
9.5 When measuring the pH, in order to reduce the dissolution or volatilization of the carbon
dioxide from the air and the water sample, it should not open the bottle of water sample in
advance before measuring the water sample.
10 Test Report
The test report shall include the followings.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB/T 6920-1986 be delivered?Answer: The full copy PDF of English version of GB/T 6920-1986 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB/T 6920-1986_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6920-1986_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 6920-1986 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of GB/T 6920-1986?A step-by-step guide to download PDF of GB/T 6920-1986_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB/T 6920-1986". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|