HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 39880-2021 English PDF

US$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 39880-2021: Examination methods for methadone in suspected drugs - Gas chromatography and gas chromatography-mass spectrometry
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 39880-2021English259 Add to Cart 3 days [Need to translate] Examination methods for methadone in suspected drugs - Gas chromatography and gas chromatography-mass spectrometry Valid GB/T 39880-2021

PDF similar to GB/T 39880-2021


Standard similar to GB/T 39880-2021

GB/T 28181   GA/T 1788.2   GA/T 424   GB/T 39875   GB/T 39874   

Basic data

Standard ID GB/T 39880-2021 (GB/T39880-2021)
Description (Translated English) Examination methods for methadone in suspected drugs - Gas chromatography and gas chromatography-mass spectrometry
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard A92
Word Count Estimation 14,121
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 39880-2021: Examination methods for methadone in suspected drugs - Gas chromatography and gas chromatography-mass spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Examination methods for methadone in suspected drugs - Gas chromatography and gas chromatography-mass spectrometry ICS 13.310 A92 National Standards of People's Republic of China Methadone test for suspected drugs Gas chromatography and gas chromatography-mass spectrometry Released on 2021-04-30 2021-08-01 implementation State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee

Table of contents

Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Principle 1 5 Reagent 1 6 Apparatus and equipment 2 7 Operation method 2 7.1 Qualitative analysis 2 7.2 Quantitative analysis 3 8 Evaluation and presentation of results 5 8.1 Evaluation of qualitative results 5 8.2 Evaluation of quantitative results 5 8.3 Presentation of results 6 8.4 Evaluation and expression of measurement uncertainty 6 9 Detection limit 6 Appendix A (informative appendix) Internal standard method standard solution and external standard method sample extraction operating parameters 7 Appendix B (informative appendix) Methadone related information 8

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents. This standard was proposed by the Ministry of Public Security of the People's Republic of China. This standard is under the jurisdiction of the National Criminal Technology Standardization Technical Committee (SAC/TC179). This standard was drafted by. Material Evidence Appraisal Center of the Ministry of Public Security. The main drafters of this standard. Gao Lisheng, Zhang Chunshui, Zheng Hui, Zhao Yang, Qian Zhenhua, Chang Ying, Zhai Wanfeng, Li Peng, Zhao Yanbiao, Yang Hongxian, Zheng Xiaoyu, Wen Wu, Liu Klin, Huang Xing, Wang Yi, Wang Weixin. Methadone test for suspected drugs Gas chromatography and gas chromatography-mass spectrometry

1 Scope

This standard specifies the gas chromatography-mass spectrometry (GC-MS) qualitative inspection method and the gas chromatography (GC) quantitative inspection method of methadone. Management, reagents and materials, instruments and equipment, operating methods, and result evaluation and presentation. This standard applies to the qualitative and quantitative analysis of methadone in solid samples of suspected drugs.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 27418 Evaluation and Expression of Uncertainty in Measurement GA/T 122 Terminology for toxicological analysis

3 Terms and definitions

The terms and definitions defined in GA/T 122 are applicable to this document.

4 Principle

Extract methadone from solid samples of suspected drugs. Detect by gas chromatography-mass spectrometry, with retention time and characteristic ion fragments And ion abundance ratio is used as the basis for qualitative judgment; gas chromatographic detection is used, and the chromatographic peak area is used as the quantitative basis, and the external standard single-point method or internal standard method is used as the quantitative basis. Standard curve method for quantitative analysis.

5 Reagents

Unless otherwise specified, the reagents used in the analysis are chromatographically pure. 5.1 Methanol. 5.2 Internal standard substance. diphenhydramine (purity not less than 95%). 5.3 Standard material stock solution. 1.0mg/mL methadone standard material stock solution, stored at 0℃~4℃, valid for 12 months. 5.4 Internal standard stock solution for quantitative internal standard curve method. Weigh 500 mg of diphenhydramine and dilute it with methanol into a 50 mL volumetric flask. Into 10.0mg/mL diphenhydramine internal standard stock solution. Store at 0℃~4℃, the validity period is 12 months. 5.5 Standard working solution for qualitative use. Pipette an appropriate amount of the methadone standard substance stock solution, dilute it with methanol, and prepare a 0.1 mg/mL methadone Ketone standard working solution. Keep refrigerated at 0℃~4℃, the validity period is 3 months. 5.6 Qualitative control standard working solution. Pipette an appropriate amount of methadone standard substance stock solution, dilute with methanol, and prepare 0.002mg/mL Methadone standard working solution. Store under refrigeration at 0℃~4℃, the validity period is 1 month. 5.7 Standard working solution for external standard single-point method quantification. Pipette an appropriate amount of methadone standard substance stock solution, dilute with methanol, and prepare 0.1mg/mL Methadone standard working solution. Keep refrigerated at 0℃~4℃, the validity period is 3 months.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 39880-2021_English be delivered?

Answer: Upon your order, we will start to translate GB/T 39880-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 39880-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 39880-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.