GB/T 10151-2008 related PDF English

GB/T 10151-2008 (GB/T10151-2008, GBT 10151-2008, GBT10151-2008) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB/T 10151-2008English150 Add to Cart 0-9 seconds. Auto delivery. Medical diagnostic X-ray equipment -- Specifications for high voltage cable plugs and sockets GB/T 10151-2008 Valid GBT 10151-2008
GB 10151-1988English279 Add to Cart 3 days Medical X-ray equipment--Specification for high voltage cable plug and socket connections GB 10151-1988 Obsolete GB 10151-1988
Buy with any currencies (Euro, JPY, KRW...): GB/T 10151-2008    Preview this PDF: GB/T 10151-2008



GB/T 10151-2008: PDF in English (GBT 10151-2008)
GB/T 10151-2008 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.50 C 43 Replacing GB 5579-1985, GB 10151-1988 Medical Diagnostic X-ray Equipment - Specifications for High Voltage Cable Plugs and Sockets ISSUED ON. NOVEMBER 3, 2008 IMPLEMENTED ON. OCTOBER 1, 2009 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Terms and Definitions ... 4  3 Compositions ... 4  4 Requirements... 5  5 Test Methods ... 15  Medical Diagnostic X-ray Equipment - Specifications for High Voltage Cable Plugs and Sockets 1 Scope This Standard specifies the terms, compositions, requirements and test methods of high voltage cable plugs and sockets (hereinafter referred to as plugs and sockets) for medical diagnostic X-ray equipment. This Standard is applicable to plugs and sockets that use three cores and four cores (double focus with grid control) on medical diagnostic X-ray equipment. The rated voltage of the plugs and sockets shall be 75 kV. 2 Terms and Definitions The following terms and definitions are applicable to this Standard. 2.1 Plug Plug refers to a plug-in, which is assembled together with high voltage cables for the connection with high voltage generator and X-ray tube assembly. 2.2 Socket Socket refers to a plug-in, which is installed on high voltage generator or X-ray tube assembly for high voltage connection. 2.3 Rating Voltage Rating voltage refers to the voltage of plugs and sockets stipulated by the manufacturer; it shall be considered as a basis of dielectric strength test. 3 Compositions Plugs and sockets shall be constituted of the following main components. 3.1 Plugs Plugs shall at least be constituted of the following components. a) Fastener; 4.2.1 The surface of plugs and sockets shall be smooth and flat; there shall be no traces or corrosion or crack. 4.2.2 Under the condition of no auxiliary renovation in any mode, their interchangeability shall be guaranteed. 4.3 Contact Resistance Contact resistance of each contact-pair of plug and socket shall be not more than 0.001 Ω (contact resistance of grid control is excluded in the restriction). 4.4 DC Withstand Voltage 4.4.1 BETWEEN the contact-pair of three-core cable plug and socket AND the ground, it shall be able to withstand 94 kV (peak value) of pulsating direct current, maintain for 15 min. 4.4.2 In terms of four-core cable plug and socket, other than satisfying the requirement in 4.4.1, between grid control contact-pair and equipotential short-circuit, it shall also withstand 8 kV (peak value) of pulsating direct current, maintain for 15 min. 4.5 AC Withstand Voltage 4.5.1 BETWEEN the contact-pair of three-core cable plug and socket AND the ground, it shall be able to withstand 70 kV (peak value) and 50 Hz of AC voltage, maintain for 5 min. 4.5.2 In terms of four-core cable plug and socket, other than satisfying the requirement in 4.5.1, between grid control contact-pair and equipotential short-circuit, it shall also withstand 5 kV (peak value) and 50 Hz of AC voltage, maintain for 5 min. 4.6 Sealing Performance The bonding of socket terminal and insulator shall be firm; there shall be no phenomenon of oil seepage. 4.7 Firmness of Plug-pin Plug-pin shall be able to withstand not less than 120 N of tensile force, maintain for 1 min. Under the stipulated effect of tensile force, plug-pin shall not have the phenomenon of loosening. 4.8 Firmness of Plugging After plugging in the socket, the pull-out force shall be not less than 30 N and not more than 100 N. After plugging in the socket, it shall be able to withstand the stipulated pull- out force. plug in the socket; after 100 times of plug-ins and plug-outs, re-conduct the test. When the DC or AC of test loop is 12 A, use millivolt meter to measure the voltage drop between the plug-pin and the socket terminal within 1 min; calculate the contact resistance, it shall comply with the stipulation in 4.3. The deviation of other test equipment shall be not more than 10%. 5.4 DC Withstand Voltage Test 5.4.1 Use detergent to wipe clean the internal and external surface of plugs and sockets; respectively conduct equipotential short-circuit on the plug-pin and socket terminal of various plugs. Then, on the external surface of plug and socket, and at a distance of 100 mm from the surface where the plug-pin and the socket terminal contact with each other, put on ring metal foil. Respectively place them into room temperature transformer oil, which has reached the requirement through certain processing. Load not more than 40 kV (peak value) of pulsating DC voltage, then, use 10 s of time to gradually rise to 94 kV (peak value), maintain for 15 min; there shall be no phenomenon of breakdown. 5.4.2 In terms of four-core cable plug and socket, other than satisfying the above- mentioned withstand voltage test, under equipotential short-circuit between grid control contact-pair and other contact-pair, load 8 kV (peak value) of pulsating DC voltage, maintain for 15 min; there shall be no phenomenon of breakdown. 5.5 AC Withstand Voltage Test 5.5.1 Use detergent to wipe clean the internal and external surface of plugs and sockets; respectively conduct equipotential short-circuit on the plug-pin and socket terminal of various plugs. Then, on the external surface of plug and socket, and at a distance of 100 mm from the surface where the plug-pin and the socket terminal contact with each other, put on ring metal foil. Respectively place them into room temperature transformer oil, which has been processed to reach the requirement. Load not more than 40 kV (peak value) and 50 Hz of AC voltage, then, use 10 s of time to gradually rise to 70 kV (peak value), maintain for 5 min; there shall be no phenomenon of breakdown. 5.5.2 In terms of four-core cable plug and socket, other than satisfying the above- mentioned withstand voltage test, under equipotential short-circuit between grid control contact-pair and other contact-pair, load 5 kV (peak value), 50 Hz, maintain for 5 min; there shall be no phenomenon of breakdown. 5.6 Sealing Performance Test 5.6.1 In exit-factory inspection. inlet 3,040 hPa of air into the socket; then, immerse it in the water. Within 10 min, no bubbles shall emerge around the socket pin. 5.6.2 In type inspection. gradually lower the temperature of the socket from room ......

BASIC DATA
Standard ID GB/T 10151-2008 (GB/T10151-2008)
Description (Translated English) Medical diagnostic X-ray equipment. Specifications for high voltage cable plugs and sockets
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C43
Classification of International Standard 11.040.50
Word Count Estimation 14,130
Date of Issue 2008-11-03
Date of Implementation 2009-10-01
Older Standard (superseded by this standard) GB 10151-1988; GB 5579-1985
Drafting Organization Liaoning Medical Device Testing
Administrative Organization National medical X-ray equipment and utensils for Standardization Technical Committee
Regulation (derived from) National Standard Approval Announcement 2008 No.18 (Total No.131)
Proposing organization State Food and Drug Administration
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies the diagnostic X-ray equipment with high voltage cable plugs, socket (hereinafter referred to as plug, socket) terms, composition, requirements and test methods. This standard applies to the medical diagnostic x-ray equipment to use three-core and quad -core (dual-focus with gated) plugs, socket. Plugs, rated voltage outlet for 75kV.