US$809.00 ยท In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19042.6-2023: Evaluation and routine testing in medical imaging departments - Part 3-6: mammographic X-ray equipment used in a mammographic tomosynthesis mode of operation imaging performance acceptance and constancy tests Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 19042.6-2023 | English | 809 |
Add to Cart
|
6 days [Need to translate]
|
Evaluation and routine testing in medical imaging departments - Part 3-6: mammographic X-ray equipment used in a mammographic tomosynthesis mode of operation imaging performance acceptance and constancy tests
| Valid |
GB/T 19042.6-2023
|
PDF similar to GB/T 19042.6-2023
Basic data Standard ID | GB/T 19042.6-2023 (GB/T19042.6-2023) | Description (Translated English) | Evaluation and routine testing in medical imaging departments - Part 3-6: mammographic X-ray equipment used in a mammographic tomosynthesis mode of operation imaging performance acceptance and constancy tests | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | C43 | Classification of International Standard | 11.040.50 | Word Count Estimation | 40,483 | Date of Issue | 2023-11-27 | Date of Implementation | 2024-12-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 19042.6-2023: Evaluation and routine testing in medical imaging departments - Part 3-6: mammographic X-ray equipment used in a mammographic tomosynthesis mode of operation imaging performance acceptance and constancy tests
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11:040:50
CCSC43
National Standards of People's Republic of China
Evaluation and routine testing of medical imaging departments
Part 3-6: Breast tomosynthesis imaging mode
Mammography X-ray equipment imaging performance acceptance and
Stability test
constancytests
Published on 2023-11-27 and implemented on 2024-12-01
State Administration for Market Regulation
Released by the National Standardization Administration Committee
Table of contents
Preface III
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms, definitions, symbols and abbreviations 1
3:1 Terms and definitions 1
3:2 Symbols and abbreviations 4
4 General principles for acceptance testing 4
4:1 Requirements Level 4
4:2 Test procedure 4
4:3 Documents and data required for testing 5
4:4 Test conditions 5
4:5 Test range 5
4:6 Test equipment 6
4:7 Evaluation of test results 7
5 General rules for stability testing 7
5:1 Establishment of benchmark values 7
5:2 Frequency of stability tests 7
6 Breast tomosynthesis imaging equipment trial overview 7
7 Breast Tomosynthesis Imaging Equipment Test Checklist and Initial Testing 9
7:1 Requirements 9
7:2 Test methods 9
7:3 Stability test 9
7:4 Taking measures 9
8 Alignment and alignment check 9
8:1 Requirements 9
8:2 Test methods 9
8:3 Stability test 10
8:4 Test equipment10
8:5 Take measures10
9 Automatic exposure control (AEC) system 10
9:1 General 10
9:2 Short-term repeatability10
9:3 Long-term repeatability11
9:4 Automatic exposure control (AEC) performance12
10 Image receiver 14
10:1 Response function 14
10:2 Detector dead pixel 15
10:3 Uncorrected detector dead pixels16
10:4 System projection MTF 17
11 Reconstructed image quality 18
11:1 Model test 18
11:2 z-axis resolution (artifact diffusion function) 18
12 missing tissue 20
12:1 General 20
12:2 Tissue loss on the chest wall side of tomographic reconstruction images 21
12:3 Tissue loss at the top and bottom of tomographic reconstruction 21
13 Artifacts in tomographic data 23
13:1 Overview 23
13:2 Artifact assessment 23
13:3 Geometric distortion 23
14 Dose in digital breast tomography 25
14:1 Requirement 25
14:2 Test method 25
14:3 Stability test 26
14:4 Test equipment 27
14:5 Taking measures 27
Appendix A (informative) Digital mammography tomosynthesis dose calculation table 28
Appendix B (Normative) Operation Guide 31
B:1 First non-compliance with test determination criteria31
B:2 Repeated non-compliance with determination criteria31
B:3 Minor non-compliance with determination criteria31
B:4 There are historical records that repeatedly fail to meet the determined criteria31
B:5 Serious non-compliance with determination criteria31
B:6 Measures not included in B:1~B:531
Appendix C (informative) Image quality assessment 32
Appendix D (informative) Artifact 33
Reference 34
Foreword
This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents"
Drafting:
This document is Part 3-6 of GB/T 19042 "Evaluation and Routine Testing of Medical Imaging Departments": GB/T 19042 has been released
The following sections are included:
---Part 3-1: Imaging performance acceptance test of X-ray equipment for X-ray photography and fluoroscopy systems;
---Part 3-2: Mammography X-ray equipment imaging performance acceptance test;
---Part 3-3: Digital subtraction angiography (DSA) X-ray equipment imaging performance acceptance test;
---Part 3-4: Dental X-ray equipment imaging performance acceptance test;
---Part 3-5: X-ray computed tomography equipment imaging performance acceptance test and stability test;
---Part 3-6: Imaging performance acceptance and stability test of mammography X-ray equipment in breast tomosynthesis imaging mode:
This document is modified to adopt IEC 61223-3-6:2020 "Evaluation and routine testing of medical imaging departments Part 3-6: Acceptance and stabilization
Experimental study on the imaging performance of mammography X-ray equipment in breast tomosynthesis imaging mode:
The technical differences between this document and IEC 61223-3-6:2020 and their reasons are as follows:
---Replaced IEC 60601-2-45 with GB 9706:245-2020 (see Chapter 3 and related provisions);
---Replaced IEC 61223-3-2:2007 with GB/T 19042:2 (see Chapter 3 and related provisions);
---Replaced IEC 61674:2012 with GB/T 19629 (see Chapter 3 and related provisions);
---Change "anode/filtration" to "target/filtration" (see 4:6:3, 10:1:3);
---Modify "When the results of the acceptance test meet the expected value, this value will be used as the benchmark value for subsequent stability tests:" in the Scope chapter to No: 5
Chapter, and add the voluntary verb "can" to express the degree of requirement (see 5:1):
The following editorial changes have been made to this document:
---In order to coordinate with the existing standards, the name of the standard is changed to "Evaluation and Routine Testing of Medical Imaging Departments Part 3-6: Breast Gland Transsection"
Imaging performance acceptance and stability test of mammography X-ray equipment in layer synthesis imaging mode";
---Deleted the note on English language;
---Adjusted references;
--- Removed terminology index:
Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:
This document is proposed by the State Food and Drug Administration and is under the jurisdiction of the National Technical Committee for Standardization of Medical Electrical Appliances (SAC/TC10):
This document was drafted by: Liaoning Provincial Medical Device Inspection and Testing Institute, Shenzhen Sennuo Medical Equipment Co:, Ltd:, Daying Medical (Zhongshan)
Co:, Ltd:, Beijing Haoluojie Technology Co:, Ltd:, Shanghai Aohua Endoscopy Co:, Ltd:, and Fujifilm (China) Investment Co:, Ltd:
The main drafters of this document: Guo Baijun, Jin Yubo, Sun Zhiyong, Li Wenyu, Wu Tao, Shao Changyun, Qian Chunjian, Meng Zhaoyang, Tang Zhiwei:
Introduction
GB/T 19042 "Evaluation and Routine Testing of Medical Imaging Departments" establishes a system of diagnostic X-ray equipment acceptance and stability test methods
The system is divided into the following 6 parts:
---Part 3-1: Acceptance test of imaging performance of X-ray equipment for X-ray photography and fluoroscopy systems: The purpose is to give X-rays
Test methods and requirements related to X-ray equipment for photography and fluoroscopy systems:
---Part 3-2: Mammography X-ray equipment imaging performance acceptance test: The purpose is to provide the cost of mammography X-ray equipment
Like relevant test methods and requirements:
---Part 3-3: Digital subtraction angiography (DSA) X-ray equipment imaging performance acceptance test: The purpose is to give the number minus
Test methods and requirements related to angiography X-ray equipment:
---Part 3-4: Dental X-ray equipment imaging performance acceptance test: The purpose is to give tests related to dental X-ray equipment
methods and requirements:
---Part 3-5: X-ray computed tomography equipment imaging performance acceptance test and stability test: The purpose is to give X
Test methods and requirements related to radiographic computed tomography equipment:
---Part 3-6: Imaging performance acceptance and stability test of mammography X-ray equipment in breast tomosynthesis imaging mode: Head
The aim is to provide the test methods and requirements related to mammography X-ray equipment imaging in breast tomosynthesis imaging mode:
This document establishes the imaging performance acceptance and stability testing of mammography X-ray equipment in breast tomosynthesis imaging mode
method:
Evaluation and routine testing of medical imaging departments
Part 3-6: Breast tomosynthesis imaging mode
Mammography X-ray equipment imaging performance acceptance and
Stability test
1 Scope
This document applies to the image quality and dose-related performance of mammography X-ray equipment in mammography tomosynthesis mode:
This document does not apply to the following situations:
---Operating modes other than the mammography tomosynthesis mode of mammography X-ray equipment;
---2D images generated from tomosynthesis images;
---Reconstructive tomography other than mammography tomosynthesis;
---CT scanning devices covered by GB/T 19042:5:
This document defines:
a) describe the basic parameters of accepted standards for tomosynthesis operating modes of mammography X-ray equipment in terms of image quality and dose;
b) Methods to detect whether the measured values related to these parameters comply with the specified deviation;
c) Frequency of stability testing when necessary:
This document is intended to be relevant to GB/T 19042:2 or equivalent specifications for 2D mammography related to mammography tomosynthesis operating modes:
Use together with the included acceptance criteria:
These methods are mainly based on non-intrusive measurements using appropriate test equipment and are carried out during or after installation: During the installation process
, a signed declarative document containing the steps of this document can be used as part of the acceptance testing: Testing in high-level compliance requirements
Take precedence over similar tests in lower-level compliance requirements:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to
this document:
GB 9706:245-2020 Medical electrical equipment Part 2-45: Mammography equipment and stereotaxic mammography equipment
Special requirements for basic safety and basic performance of equipment (IEC 60601-2-45:2015, MOD)
GB/T 19042:2 Evaluation and routine testing of medical imaging departments Part 3-2: Imaging performance test of mammography X-ray equipment
Acceptance test (GB/T 19042:2-2005, IEC 61223-3-2:1996, IDT)
GB/T 19629 Ionization chamber and/or semiconductor detector dosimeter used in X-ray diagnostic imaging of medical electrical equipment
(GB/T 19629-2005,IEC 61674:1997,IDT)
3 Terms, definitions, symbols and abbreviations
3:1 Terms and definitions
The following terms and definitions as defined in GB 9706:245-2020 and GB/T 19042:2 apply to this document:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19042.6-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 19042.6-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 19042.6-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19042.6-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|