Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB 50352-2019English425 Add to Cart 0-9 seconds. Auto-delivery Uniform standard for design of civil buildings Valid
GB 50352-2005English150 Add to Cart 0-9 seconds. Auto-delivery Code for design of civil buildings Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB 50352-2019
      

Similar standards

GB 50325   GB/T 50378   GB 50343   GB/T 50362   

GB 50352-2019: Uniform standard for design of civil buildings

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB50352-2019
NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA UDC Uniform standard for design of civil buildings Issued on. MARCH 13, 2019 Implemented on. OCTOBER 1 01, 2019 Issued by. Ministry of Housing and Urban-Rural Development of the People's Republic of China; General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. National Standard of the People's Republic of China Uniform standard for design of civil buildings Drafted by. the Ministry of Housing and Urban-Rural Development of the People's Republic of China Approved by. the Ministry of Housing and Urban-Rural Development of the People's Republic of China Implementation Date. October 1, 2019 2019 Beijing Ministry of Housing and Urban-Rural Development of the People's Republic of China Announcement 2019 No. 57

Table of Contents

Foreword... 6 1 General provisions... 8 2 Terms... 10 3 Basic requirements... 14 4 Planning control... 20 5 Site planning... 26 6 Architecture design... 34 7 Indoor environment... 56 8 Building implements... 61 Explanation of wording in this standard... 76 List of quoted standards... 77

1 General provisions

1.0.1 In order to meet the "applicable, economic, green and beautiful building" principles for civil buildings, to meet the basic requirements of safety, sanitation and environmental protection, and to unify the general design requirements of various civil buildings, this standard is prepared. 1.0.2 This standard is applicable to the design for new construction, extension and renovation of civil building. 1.0.3 In addition to the implementation of relevant national laws and regulations, civil building design shall also meet the following requirements.

2 Terms

2.0.1 civil building the general term of the building for people living and public activities 2.0.2 residential building building for people to live and use 2.0.3 public building building for people to conduct various public activities 2.0.4 accessibility facilities service facilities to ensure safe passage and convenient use of personnel, and to be constructed in conjunction with civil construction projects. 2.0.5 construction site site for the construction project, which is determined according to the nature of the land and the use of ownership 2.0.6 boundary line of roads boundary line of land for urban roads (including residential area roads) 2.0.10 plot ratio; floor area ratio the ratio of the total area of the building to the area of the land within a certain land use and floor use range 2.0.17 equipment floor space layer specially for the equipment and pipelines of HVAC, air conditioning, water supply and drainage, electrical engineering, etc., and for personnel to enter for operation 2.0.18 refuge storey storey for the personnel to hide from fire and smoke hazard temporarily in case of fire in high-rise buildings with a height of more than 100.0m 2.0.19 open floor open space for structure support and without peripheral retaining wall 2.0.20 step stepped passage for pedestrians connected to indoors or outdoors floors or grounds of different elevations

3 Basic requirements

3.1 Classification of civil buildings 3.1.1 Civil buildings can be classified into residential buildings and public buildings according to their functions. In addition, residential buildings can be classified into residential buildings and dormitory buildings. 3.1.2 Classification of civil buildings according to the height or floor number of the building shall comply with the following provisions. 3.1.3 The grading of civil building grades shall be in accordance with the relevant national standards or the regulations of the competent authorities of the industry. 3.2 Designed service life 3.3 Basic requirements of climate region of building 3.3.1 Basic requirements of climate region of building shall be in accordance with the requirements of Table 3.3.1. 3.5 Building module 3.5.1 The architectural design shall meet the requirements of the current national standard GB 50002 Standard for modular coordination of building. 3.5.2 The dimensions of the main positioning lines of the building plane, such as column net, bay, depth, storey height, door and window openings, shall be multiples of the basic modulus and meet the following requirements. 3.6 Disaster prevention and asylum 3.6.1 The setting of disaster prevention shelters or facilities shall meet the overall requirements of urban and rural planning, and shall follow the principles of site safety, convenient transportation and easy access. 3.6.2 The architectural design shall cover appropriate measures for disaster prevention, mitigation and refuge according to the types of disasters.

4 Planning control

4.1 Urban planning and city design 4.1.1 Control indicators such as the land use nature, plot ratio, building density, greenbelt rate, building height of for construction projects and annual runoff total control rate of its construction base shall conform to the relevant provisions of the local controlled detailed planning. 4.1.3 Architectural design shall be stressed in the integration and coordination of architectural group space and natural landscape environment, the protection and development of historical culture and traditional features, the organization and shaping of public activities and public space, and shall meet the following requirements. 4.2 Construction base site 4.2.1 The construction base shall be adjacent to urban roads or township roads, otherwise, connecting roads shall be set up and shall meet the following requirements. 4.2.2 The ground elevation of the construction base shall meet the following requirements. 4.3 Building surface eruption 4.3.1 Except for arcade buildings, building connection, subway-related facilities and municipal public facilities such as pipelines, pipe trenches and pipe corridors connecting cities, buildings and the following ancillary facilities shall not be built in a way that protruding out of boundary line of roads or property line. 4.3.3 Except for basements, window wells, steps of building entrances, ramps, awnings, etc., the main body of the building (structure) shall not protrude the building line. 4.3.4 Public security boxes, bus shelters, subways, underground tunnels, overpasses and other related facilities, as well as temporary buildings (structures) etc., if necessary and without affecting traffic and fire safety, may protrude into the red line of the road for construction upon the approval by the local planning administrative department. 4.3.5 The construction of arcade buildings, building joints and overhanging buildings along boundary line of roads shall not affect traffic, environmental protection and fire safety. In the urban public space with a top cover, there shall be no direct exhaust air conditioner, exhaust fan and other facilities or other ventilation systems to exhaust harmful gases.

5 Site planning

5.1 Architectural composition 5.1.1 The architectural composition shall enable the rational shunt of people, traffic and logistics in the building base to prevent interference of them, and shall be conducive to firefighting, parking, personnel distribution and accessibility facilities. 5.2 Road and hard standing 5.2.1 Base roads shall meet the following requirements. 5.2.4 The buffer section shall be built between the entrance / exit of the motor vehicle garage and the connecting road within the construction base. The buffer section shall start from the hillslope of the garage entrance / exit ramp and meet the following requirements. 5.3 Vertical design 5.3.1 The design for construction site shall meet the following requirements. 5.5 Layout of pipeline engineering 5.5.1 Pipelines should be laid underground; the engineering pipelines laid overhead and the facilities for them must meet the requirements of fire-fighting vehicle transit and rescue, not interfering with the normal activities of ordinary vehicles and pedestrians, and avoiding the impact on buildings and landscapes.

6 Architecture design

6.1 Determining of rate number of users 6.1.1 For the building indicating the number of users like the number of user seats, the width of the supporting facilities, exit passageways, stairs and safety exits shall be calculated based on the rate number of users. 6.2 Layout design 6.2.1 The layout of the building shall be made proper and flexible in consideration of the building use nature, function, process and other factors. 6.3 Storey height and interior clear height 6.3.1 Building storey height shall be determined by use function, technological requirements, technical and economic conditions of building and other factors, and meet the requirements of current relevant national standards for building design. 6.4 Basement and semibasement 6.4.1 Function spaces like underground parking garage, civil air defense shelter and equipment rooms as well as their entrance / exit shall be arranged in a reasonable way in basement and semibasement; the entrance / exit and ground building (structure) for air intake and exhaust shafts shall be make coordinated with the surrounding environment.

7 Indoor environment

7.1 Lighting environment 7.1.1 The daylighting calculation of main function rooms in buildings shall meet the requirements of current national standard GB/T 50033 Standard for daylighting design of buildings. 7.1.3 The calculation of the effective daylighting window area shall meet the following requirements. 7.3 Thermal environment 7.3.1 Buildings requiring heat protection in summer shall meet the following requirements. 7.4.5 For concert halls, theaters, cinemas, multi-purpose halls, stadiums, terminals and various transportation passenger stations and other important buildings with special acoustic requirements, special design for building acoustics and sound-reinforcement systems should be performed based on functional positioning and usage requirements. 7.4.6 For densely populated indoor places, noise reduction design shall be performed.

8 Building implements

8.1 Water supply and drainage 8.2 Heating ventilating and air conditioning 8.2.2 The civil building with the machinery ventilation system shall meet the following requirements. 8.4 Gas 8.4.1 The outdoor gas pipeline should be buried and laid, which shall meet the following requirements. 8.4.4 The pressure regulator box or special pressure regulating device may be hung on the exterior wall of the residential building with the fire resistance grade not lower than Grade II, and the fire resistance limit of the exterior wall body shall not be less than 2.5 h. 8.4.5 When the inlet pressure of the pressure regulating device is not greater than 0.4 Mpa, and the inlet and outlet pipe diameter of the pressure regulating device is not greater than DN100, it may be set on the flat roof of the building that use gas, and shall meet the following requirements. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB 50352-2019 be delivered?

Answer: The full copy PDF of English version of GB 50352-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 50352-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB 50352-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB 50352-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB 50352-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 50352-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB 50352-2019?

A step-by-step guide to download PDF of GB 50352-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 50352-2019".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9