GB 28378-2019 (GB28378-2019) & related versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | See Detail | Status | Similar PDF |
GB 28378-2019 | English | 135 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
Minimum allowable values of water efficiency and water efficiency grades for showers
|
GB 28378-2019
| Valid |
GB 28378-2019
|
GB 28378-2012 | English | 90 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
Minimum allowable values of water efficiency and water efficiency grades for showers
|
GB 28378-2012
| Obsolete |
GB 28378-2012
|
Buy with any currencies (Euro, JPY, KRW...): GB 28378-2019 Preview this PDF: GB 28378-2019
GB 28378-2019
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 91.060
Y 71
Replacing GB 28378-2012
Minimum Allowable Values of Water Efficiency
and Water Efficiency Grades for Showers
ISSUED ON: DECEMBER 31, 2019
IMPLEMENTED ON: JULY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Terms and Definitions ... 5
4 Water Efficiency Grade of Shower ... 6
5 Technical Requirements ... 6
6 Test Methods ... 7
Appendix A (Normative) Test Methods ... 8
Minimum Allowable Values of Water Efficiency
and Water Efficiency Grades for Showers
1 Scope
This Standard specifies the water efficiency grade, technical requirements and test
methods of showers.
This Standard is applicable to the water efficiency evaluation for the showers (including
sprinkler or sprinkler combinations) that is used in the shower room and other sanitary
facilities, and that is installed at the end of the cold and hot water supply pipelines in
the building, with a nominal pressure (static pressure) no greater than 1.0MPa, and
medium temperature of 4°C ~90°C.
This Standard is not applicable to showers with their own heating device and
thermostatic showers.
2 Normative References
The following documents are essential to the application of this document. For the
dated documents, only the versions with the dates indicated are applicable to this
document; for the undated documents, only the latest version (including all the
amendments) is applicable to this document.
GB/T 33733 Terminology and Classification for the Kitchen and Sanitary Ware
Fittings
3 Terms and Definitions
For the purpose of this document, the terms and definitions given in GB/T 33733 and
the following apply.
3.1 Uniformity of flow; ΔF
Under different test pressures, the difference between the highest average flowrate
and the lowest average flowrate of the hand-held sprinkler for the shower.
3.2 Minimum allowable values of water efficiency for showers
Test according to Appendix A, the average spray force of the hand-held sprinkler shall
be no less than 0.85N.
NOTE: If the sprinkler has multiple water outlet methods, take the maximum average spray
force.
5.3 Uniformity of flow
Test according to Appendix A, the maximum water flow uniformity of the hand-held
sprinkler for the shower shall be no greater than 4.0 L/min.
5.4 Minimum allowable values of water efficiency for showers
The minimum allowable values of water efficiency for showers indicate Grade-3 water
efficiency.
5.5 Evaluating values of water conservation for showers
The evaluating values of water conservation for the showers indicate Grade-2 water
efficiency.
6 Test Methods
The test methods for spray force, flowrate and uniformity of flow for showers shall be
implemented in accordance with Appendix A.
A.1.2 Spray force test procedures
The spray force test is carried out according to the following procedures:
a) The hand-held sprinkler and its accessories (such as shower valve, water-
separating switch, straight pipe/elbow shower column or shower hose, etc.) shall
be assembled according to the assembly method provided by the manufacturer;
b) For the hand-held sprinkler with various water outlet methods, adjust it to the
maximum spray force for test;
c) Install the hand-held sprinkler on the test bench, and connect the water to the
hand-held sprinkler water inlet (for the hand-held shower connected to the hose,
install it on the test bench so that the hose hangs freely in a U shape, no distortion,
hand-held sprinkler panel is horizontal);
d) The spray sphere is installed on the spray force measuring device;
e) Check whether the vertical axis of the spray force measuring device is
perpendicular to the horizontal plane;
f) Adjust the hand-held sprinkler water outlet panel so that it is placed horizontally,
and the vertical distance between it and the spray spherical dome is
400mm~405mm;
g) Pass water to the hand-held sprinkler and gradually adjust the dynamic pressure
to (0.50±0.01) MPa through the pressure regulating device, and keep the
dynamic pressure stable for at least 60s;
h) Turn off the water flow; and then gradually turn on the water flow to adjust the
pressure to (0.30±0.01) MPa; and then read the reading P1 of the spray force
test device after maintaining stability (at least stable for 10s);
i) Repeat Procedure h), the pressure drops to (0.20±0.01) MPa and (0.10±0.01)
MPa; and read P2 and P3;
j) Calculate the average value of P1, P2 and P3 as the average spray force.
A.2 Flowrate test
A.2.1 Flowrate test device
A.2.1.1 Water supply device
The water supply device shall include:
a) A pressure regulating device that can continuously maintain the pressure
required by the standard;
A.2.3 Flowrate test procedures
The flowrate test of various showers is carried out according to the following
procedures:
a) Single handle dual control shower
Connect the shower to the test device according to Figure A.2; turn the handle
to the maximum position of cold and hot water and to the position of the
maximum flowrate of mixed water respectively; record the flowrate when the
flowrate is stable at each position; and take the maximum value of the flowrate.
b) Double handle double control shower
Connect the shower to the test device according to Figure A.2; turn the handle
to the maximum position of cold and hot water and turn the hot and cold water
to the maximum position at the same time; record the flowrate when the flowrate
is stable at each position; and take the maximum value of the flowrate.
c) Single handle single control shower
Connect the shower to the test device according to Figure A.2; turn the handle
to the maximum flowrate at the water outlet position; and record the flowrate
when the flowrate is stable.
A.3 Flowrate uniformity test
A.3.1 Flowrate uniformity test device
The flowrate uniformity test device shall meet the requirements of A.2.1.
A.3.2 Flowrate uniformity test procedures
A.3.2.1 Connect the shower to the test device according to Figure A.2.
A.3.2.2 Adjust the water inlet pressure to a dynamic pressure of 0.50 MPa; and after
turning-on for 1 min, successively adjust to the dynamic pressure (0.30 ± 0.01) MPa,
(0.20 ± 0.01) MPa and (0.10 ± 0.01) MPa, each test 3 times; record the flowrate when
the flowrate is stable under each pressure; respectively calculate the average value;
and calculate the difference between the maximum average flowrate and the minimum
average flowrate.
A.3.2.3 The pressure is tested in turn from high to low, and the test process is as
follows:
a) The flowrates of the 3 tests at (0.30±0.01) MPa are f11, f12, and f13, and the
average value is F1=(f11+f12+f13)/3;
......
GB 28378-2012
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 91.060
Y 71
Minimum Allowable Values of Water Efficiency
and Water Efficiency Grades for Showers
ISSUED ON. APRIL 1, 2012
IMPLEMENTED ON. APRIL 1, 2013
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 4
4 Technical Requirements ... 5
5 Test Methods ... 6
6 Instructions for Water Efficiency Grades ... 7
Foreword
The Clause 4.2, 4.3 and 4.5 in this Standard are mandatory, while the rest are
recommended.
This Standard was drafted as per the rules specified in GB/T 1.1-2009.
This Standard was proposed by Ministry of Water Resources of National Development
and Reform Commission.
This Standard shall be under the jurisdiction of Subcommittee on Water Efficiency of
Water-Using Products and Appliances of National Technical Committee for
Standardization of Industrial Water Conservation (SAC/TC 442/SC 1).
Drafting organizations of this Standard. National Center for Supervision & Inspection
of Drainage Irrigation & Water-Saving, China National Institute of Standardization,
Shenluda Group Co., Ltd., Jomoo Group Co., Ltd., Brilliant Plumbing Group Co., Ltd.,
Joyou Group Co., Ltd., Lejia Sanitary Equipment (Foshan) Co., Ltd., Hecheng (China)
Co., Ltd., Fujian Fuquan Group Co., Ltd., Chaoan Konna Sanitary Wares Co., Ltd.,
Guangdong Chaozhou Mengjia Ceramics Industry Co., Ltd., Guangdong Oumer
Industrial and Commercial Co., Ltd., Chaozhou Muye Ceramics Manufacture Co., Ltd.,
Chaozhou Uncommon Craft Industrial Co., Ltd., Chaoan Pengwang Ceramic Industrial
Co., Ltd., Chaoan Oubeier Sanitary Ware Co., Ltd., Guangdong Oulu Sanitary Ware
Co., Ltd., Heshan Kangliyuan Sanitary Ware Industry Co., Ltd., CAE Sanitary Fittings
Industry Co., Ltd., Foshan City Faenza Sanitary Ware Co., Ltd., Kaiping City Jinhuifeng
Industrial Co., Ltd., Hefei Royalstar Electronic Appliances Co., Ltd., Fujian Provincial
Central Testing Institute, and Shanghai Institute of Quality Inspection and Technical
Research.
Chief drafting staffs of this Standard. Zhu Shuangsi, Bai Xue, Zhu Chunyan, Hong
Jiancheng, Lin Xiaofa, Weng Xianmin, Jin Minghong, Cheng Xiaomin, Zheng Aifen,
Zhu Yijun, Tang Minjun, Wang Jianye, Cai Jianshe, Peng Yiqun, Shao Zeliang, Hong
Jinfu, Chen Shuding, Su Xibo, Chen Keping, Huang Lihui, Zheng Xibiao, Su Shuzhou,
Chen Shaowei, Chen Fangqing, Huang Jiyuan, Huang Zhenhuai, Yan Bangping, Liu
Yaqing, and Pan Baochun.
Minimum Allowable Values of Water Efficiency
and Water Efficiency Grades for Showers
1 Scope
This Standard specifies the minimum allowable values of water efficiency, water-saving
evaluation values, water efficiency grades, technical requirements and test methods
for showers.
This Standard is applicable to the shower with nominal pressure no greater than
1.0MPa, water medium temperature no greater than 90°C, installed in the washroom
(toilet, bathroom), shower room and other sanitary facilities.
This Standard is not applicable to the shower with its own heating device.
2 Normative References
The following documents are essential to the application of this document. For the
dated documents, only the versions with the dates indicated are applicable to this
document; for the undated documents, only the latest version (including all the
amendments) are applicable to this document.
GB/T 8170-2008 Rules of Rounding off for Numerical Values & Expression and
Judgement of Limiting Values
3 Terms and Definitions
The following terms and definitions are applicable to this document.
3.1 Showers for bathing
The showering apparatus consists of valve body, sprinkler, connecting pipe and other
components.
3.2 Difference among flow rates
Under the specified dynamic pressure, the difference between the maximum average
flow rate and the minimum average flow rate.
3.3 Minimum allowable values of water efficiency for showers
The maximum allowable flow rate of shower.
3.4 Water efficiency grades for showers
It is confirmed as per the difference among flow rates and flow rate values, can be
divided into Grade-1, Grade-2, and Grade-3; thereof, Grade-1 indicates the maximum
water efficiency, while the Grade-3 indicates the minimum allowable values of water
efficiency.
3.5 Rated water efficiency grade
When the shower leaves the factory, the manufacturer indicates the water efficiency
grade for the shower according to the provisions of this Standard.
4 Technical Requirements
4.1 Basic requirements
Shower shall meet the express requirements of the product. This Standard data
judgment adopts the rounding off comparison method; the rounding off of the numerical
values shall be performed as per the provisions of GB/T 8170-2008; the digits of
rounding off is consistent with the digits of the aforementioned minimum allowable
values.
4.2 Difference among flow rates
Under the dynamic pressures of (0.10±0.01) MPa, (0.20±0.01) MPa and (0.30±0.01)
MPa, the difference among flow rates is no greater than 0.10L/s.
4.3 Minimum flow rate
Under the dynamic pressure of (0.30±0.01) MPa, the flow rate shall be no less than
0.07L/s.
4.4 Water efficiency grades for showers
Under the dynamic pressure of (0.10±0.01) MPa, the water efficiency grades for
showers shall be judged as per Table 1; such water efficiency grade shall be no less
than the rated water efficiency for showers.
Table 1 -- Water Efficiency Grade Indexes for Showers
Water Efficiency Grades Grade-1 Grade-2 Grade-3
Flow rate / (L/s) 0.08 0.12 0.15
4.5 Minimum allowable values of water efficiency for showers
The minimum allowable values of water efficiency for showers indicate the Grade-3
water efficiency.
4.6 Water-saving evaluation values for showers
The water-waving evaluation values for showers indicate the Grade-2 water efficiency.
5 Test Methods
5.1 Test on difference among flow rates
The test on difference among flow rates (ΔF) shall be respectively performed for 3
times under the dynamic pressures of (0.10±0.01) MPa, (0.20±0.01) MPa and
(0.30±0.01) MPa; respectively calculate their average values; and calculate the
difference between the maximum average flow rate and minimum average flow rate.
3 times flow rates tested under (0.10±0.01) MPa are f11, f12, f13; average value of
F1=(f11+f12+f13)/3;
3 times flow rates tested under (0.20±0.01) MPa are f21, f22, f23; average value of
F2=(f21+f22+f23)/3;
3 times flow rates tested under (0.30±0.01) MPa are f31, f32, f33; average value of
F13=(f31+f32+f33)/3;
The maximum average value Fmax (by the actual maximum value), and the minim
average value Fmin (by the actual minimum value).
Difference among flow rates ΔF = Fmax – Fmin.
The difference among flow rates and flow rate testing device for shower shall conform
to the provisions of Figure 1.
Figure 1 -- Flow Rate Testing Device Example
Flowmeter
Pressure gauge
Sample
Pressure
source
Water-supply straight pipe no
less than 300mm
5.2 Flow rate test
The product is connected to the water-supply pipe with diameter 15mm, and formed
the using state; test it by cold water, cold water temperature ≤30°C; start the shower
valve and adjust the dynamic pressure to be 0.1MPa±0.01MPa, form stable and
continuous water flow; measure the corresponding flow rate as per the following
requirements.
a) For the single-valve single-control shower valve, adjust the handle to the
maximum position;
b) For the dual-handle dual-control shower valve, adjust the handle to the maximum
hot & cold-water positions; take the maximum flow rate value;
c) For the single-handle dual-control shower valve, adjust he handle to the maximum
hot & cold water positions, and the maximum mixed water positions (i.e. in the
middle); take the maximum flow rate value.
6 Instructions for Water Efficiency Grades
The manufacture shall confirm the product flow rate and rated water efficiency grade
according to the requirements of this Standard and test results; the product flow rate,
rated water efficiency grade, and standard number shall be indicated on the product,
in the exit-factory instructions, and on the package.
......
Standard ID | GB 28378-2019 (GB28378-2019) | Description (Translated English) | Minimum allowable values of water efficiency and water efficiency grades for showers | Sector / Industry | National Standard | Classification of Chinese Standard | Y71 | Classification of International Standard | 91.060 | Word Count Estimation | 8,827 | Date of Issue | 2019-12-31 | Date of Implementation | 2020-07-01 | Drafting Organization | Jiumu Kitchen and Bathroom Co., Ltd., China National Institute of Standardization, Guangzhou Mona Lisa Sanitary Ware Co., Ltd., Guangdong Lehua Home Furnishing Co., Ltd., National Drainage, Irrigation and Water-saving Equipment Product Quality Supervision and Inspection Center, Xiamen Water Dragonfly Sanitary Ware Technology Co., Ltd., Anhui Provincial Institute of Product Quality Supervision and Inspection, Guangdong Huayi Sanitary Ware Industry Co., Ltd., Hengjie Sanitary Ware Group Co., Ltd., Quanzhou Lianchuang Kitchen and Bathroom Co., Ltd., Foshan Jiajia Sanitary Ware Co., Ltd., Qingdao Economic and Technological Development Zone Haier Water Heater Co., Ltd., Foshan Dongpeng Sanitary Ware Co., Ltd., Hansgrohe Sanitary Ware (Shanghai) Co., Ltd., Xiamen Songlin Technology Co., Ltd., Guangdong Weixiang Sanitary Ware Industry Co., Ltd., Kaiping Hanmark Sanitary Ware Co., Ltd., Taizhou Shenhu Sanitary Ware Co., Ltd. Co., Ltd., Yinchao Sanitary Ware Technology Co., Ltd. | Administrative Organization | National Standardization Administration | Proposing organization | National Standardization Administration, Department of Resource Conservation and Environmental Protection, National Development and Reform Commission of the People's Republic of China | Issuing agency(ies) | State Administration for Market Regulation, National Standardization Administration | Standard ID | GB 28378-2012 (GB28378-2012) | Description (Translated English) | Minimum allowable values of water efficiency and water efficiency grades for showers | Sector / Industry | National Standard | Classification of Chinese Standard | Y71 | Classification of International Standard | 91.060 | Word Count Estimation | 6,683 | Quoted Standard | GB/T 8170-2008 | Drafting Organization | National irrigation and water-saving equipment Product Quality Supervision and Inspection Center | Administrative Organization | Standardization Technical Committee of the National Industrial water saving products and appliances water efficiency at the Technical Committee | Regulation (derived from) | National Standards Bulletin No. 9 of 2012 | Proposing organization | The National Development and Reform Commission and the Ministry of Water Resources | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This Chinese standard specifies the shower's water efficiency limit value, water-saving evaluation value, water efficiency rating, technical requirements and test methods. This standard applies to nominal pressure of not more than 1. 0 MPa, the water temp |
|