GB 25501-2019 PDF in English
GB 25501-2019 (GB25501-2019) PDF English
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB 25501-2019 | English | 80 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Minimum allowable values of water efficiency and water efficiency grades for faucets
| Valid |
GB 25501-2010 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Minimum allowable values of water efficiency and water efficiency grades for faucets
| Obsolete |
Standards related to (historical): GB 25501-2019
PDF Preview
GB 25501-2019: PDF in English GB 25501-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 91.060
Y 71
Replacing GB 25501-2010
Minimum allowable values of water efficiency and
water efficiency grades for faucets
ISSUED ON: DECEMBER 31, 2019
IMPLEMENTED ON: JULY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Terms and definitions ... 5
4 Technical requirements ... 6
5 Test methods ... 7
Annex A (informative) Test devices of faucets ... 9
Foreword
This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This Standard replaces GB 25501-2010 “Minimum allowable values of water
efficiency and water efficiency grades for faucets”. Compared with GB 25501-
2010, main technical changes in this Standard are as follows:
- modified the standard scope;
- modified some terms and definitions;
- modified basic requirements;
- modified indicators of flow uniformity;
- modified indicators of water efficiency grades for faucets.
This Standard was proposed by Standardization Administration of the People's
Republic of China, Department of Resource Conservation and Environmental
Protection, National Development and Reform Commission of People's
Republic of China.
This Standard shall be under the jurisdiction of Standardization Administration
of the People's Republic of China.
The drafting organizations of this Standard: Jiumu Kitchen & Bathroom Co., Ltd.,
Guangdong Huayi Sanitary Ware Industry Co., Ltd., Anhui Xueyu Sanitary Ware
Co., Ltd., Guangdong Lehua Home Furnishing Co., Ltd., Hengjie Bathroom
Group Co., Ltd., Xinle Bathroom (Foshan) Co., Ltd., Liaoning Supor Sanitary
Ware Co., Ltd., Ningbo Jiemin Sanitary Ware Technology Co., Ltd., Luda
(Xiamen) Industry Co., Ltd., Zhejiang Ruige Copper Industry Co., Ltd., Zhejiang
Gaobo Sanitary Ware Co., Ltd., Zhejiang Sulda Sanitary Ware Co., Ltd.,
Zhejiang Anma Sanitary Ware Co., Ltd., Zhejiang Zhigao Sanitary Ware Co.,
Ltd., Zhejiang Kangyi Sanitary Ware Co., Ltd., Guangdong Weixiang Sanitary
Ware Industry Co., Ltd., Kaiping Hanmak Sanitary Ware Co., Ltd., Guangdong
Conner Sanitary Ware Technology Co., Ltd., Guangdong Oumeier Industry and
Trade Industrial Co., Ltd., Kaiping Circuit Leading Fittings Co., Ltd., Xiamen
Ruierte Sanitary Technology Co., Ltd., Guangdong Zhongou Sanitary Ware Co.,
Ltd., Yiyuan (Shanghai) Energy-saving Environmental Protection Technology
Co., Ltd., Guangdong Jinen Sanitary Ware Industry Co., Ltd., Guangdong Anbi
Technology Co., Ltd., Braun (China) Sanitary Ware Co., Ltd., Huida Sanitary
Ware Co., Ltd., Guangdong Shang Hi-Tech Co., Ltd., Xiamen Haoyamei
Hardware Sanitary Ware Industry Co., Ltd., Grand Hyatt Shower Hose (Xinhui)
Co., Ltd., Foshan Dongpeng Sanitary Ware Co., Ltd., Foshan Jiajia Sanitary
Ware Co., Ltd., Quanzhou Lianchuang Kitchen & Bath Co., Ltd., Fujian Nan'an
Minimum allowable values of water efficiency and
water efficiency grades for faucets
1 Scope
This Standard specifies minimum allowable values of water efficiency,
evaluating values of water conservation, water efficiency grades and test
methods for faucets.
This Standard is applicable to water efficiency evaluation for wash-basin
faucets, kitchen faucets, bidet faucets and ordinary faucets that are mounted at
cold and hot water supply pipe ends in buildings, that the nominal pressure
(static pressure) is not greater than 1.0MPa, and the medium temperature is
4°C~90°C.
This Standard is not applicable to the faucets with delayed self-closing function.
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
GB/T 33733, Terminology and classification for the kitchen and sanitary ware
fittings
3 Terms and definitions
For the purposes of this document, the terms and definitions defined in GB/T
33733 as well as the followings apply.
3.1 uniformity of flow; ΔF
The difference between the highest average flow and the lowest average flow
of a faucet under different test pressures.
3.2 minimum allowable values of water efficiency for faucet
The maximum flow that is allowed by a faucet under standard-specified test
conditions.
The faucet flow specified in water efficiency grade 2.
5 Test methods
5.1 General provisions
5.1.1 The test devices for faucet flow and uniformity of flow tests shall meet the
requirements of Annex A.
5.1.2 Conduct pre-washing of test sample not less than 30s at a dynamic
pressure of (0.30±0.01) MPa before test.
5.1.3 The test water temperature shall be controlled at (25±3)°C.
5.2 Flow test
5.2.1 The dynamic pressure during test is (0.10±0.01) MPa.
5.2.2 The flow test steps of various faucets are as follows:
a) Single-handle single-control faucet
Connect the faucet on the test device according to Figure A.1. Open the
handle to the maximum water outlet position. Record the flow value when
the flow is stable.
b) Single-handle double-control faucet
Connect the faucet on the test device according to Figure A.1.
Respectively measure the flows at cold-water fully-open position, hot-
water fully-open position and maximum flow position of mixed water. Take
the maximum value.
c) Double-handle double-control faucet
Connect the faucet on the test device according to Figure A.1.
Respectively measure the flow at the position where cold and hot water
are turned on separately to the maximum and the flow of mixed water at
the position where hot and cold water are turned on at the same time to
the maximum. Take the maximum value.
d) Non-contact faucet
Connect the faucet on the test device according to Figure A.1. Make the
faucet at turned-on state. Record the flow value after the flow is stable.
Repeat the test 3 times. Take its arithmetic mean as the flow value of this
faucet.
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|