HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Dec 2024)

GB 18394-2020 Related PDF English (GB 18394-2001)

GB 18394-2020 (GB18394-2020) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB 18394-2020English95 Add to Cart 0-9 seconds. Auto delivery. Permitted level of moisture in meat of livestock and poultry GB 18394-2020 Valid GB 18394-2020
GB 18394-2001English199 Add to Cart 2 days Permitted level of moisture in meat of livestock and poultry GB 18394-2001 Obsolete GB 18394-2001
Buy with any currencies (Euro, JPY, KRW...): GB 18394-2020    Preview this PDF: GB 18394-2020



GB 18394-2020 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 67.120.10 X 22 Replacing GB 18394-2001 Permitted level of moisture in meat of livestock and poultry ISSUED ON: DECEMBER 24, 2020 IMPLEMENTED ON: JANUARY 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Indicators for permitted level of moisture in meat of livestock and poultry ... 4 5 Test methods ... 5 Permitted level of moisture in meat of livestock and poultry 1 Scope This Standard specifies the indicators and test methods for permitted level of moisture in meat of livestock and poultry. This Standard is applicable to fresh (frozen) pork, beef, mutton and chicken. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 5009.3-2016, National food safety standard -- Determination of moisture in food GB/T 6682, Water for analytical laboratory use -- Specification and test methods GB/T 19480, Terms of meat and meat products 3 Terms and definitions For the purposes of this document, the terms and definitions defined in GB/T 19480 apply. 4 Indicators for permitted level of moisture in meat of livestock and poultry See Table 1 for the indicators for permitted level of moisture in meat of livestock and poultry. The arbitration method for determining the moisture content of livestock and poultry meat is based on the distillation method specified in GB 5009.3-2016. Table 1 -- Indicators for permitted level of moisture in meat of livestock and poultry 5.1.3.1 Weighing vessels: flat aluminum or glass weighing vessels, porcelain crucible, inner diameter not less than 25 mm. 5.1.3.2 Homogenizing equipment: chopper or meat grinder. 5.1.3.3 Thin glass rod: slightly higher than the weighing vessel. 5.1.3.4 Constant temperature drying oven. 5.1.3.5 Dryer: containing effective desiccant. 5.1.3.6 Balance: sensitivity is 0.01 g and 0.0001 g. 5.1.4 Sample preparation 5.1.4.1 Sample collection Make an incision from the sampling site, avoiding fat, sinews, and tendons. Cut about 200 g of muscle. Place in an airtight container. Cooling meat should remove any surface air-dried parts. Frozen meat should be sampled from within the sample. 5.1.4.2 Sample processing 5.1.4.2.1 Non-frozen samples Fat, sinews, and tendons should be removed from the sample before testing. Take the muscle part and homogenize it. Homogenized samples should be tested as soon as possible. If it cannot be detected in time after homogenization, it should be stored sealed and refrigerated. Sealed and refrigerated storage time should not exceed 24 h. Stored samples should be remixed during testing. 5.1.4.2.2 Frozen samples Thaw at 15℃~25℃. Record the sample mass m3 and m4 before and after thawing (accurate to 0.01 g). Thawed samples are processed according to 5.1.4.2.1. 5.1.5 Analysis steps 5.1.5.1 Constant weight of weighing vessel: Put a thin glass rod and about 10 g of sand into the weighing vessel. Place it into a constant temperature drying oven at (103±2)℃ and maintain a constant weight. Record the mass after constant weight (m0). 5.1.5.2 Weigh about 5 g of sample (accurate to 0.0001 g) and place it in a weighing vessel. Accurately record the total mass (m1) of the sample and weighing vessel. Use a fine glass rod to mix the sand and sample evenly. 5.1.5.3 Move the weighing vessel and sample to a constant temperature drying oven at (103±2)℃. After drying for 4 h, take it out and cool it in a desiccator before weighing. Dry it again in a constant temperature drying oven for 1 h, take it out, cool it and weigh it. Repeat the above steps until the mass difference between two consecutive times is less than 2 mg. Record the total mass of the final weighing vessel and contents (m2). 5.2 Infrared drying method (quick method) 5.2.1 Principle Use infrared heating to remove moisture from the sample, and then use the mass difference before and after drying to calculate the moisture content. 5.2.2 Instruments Infrared rapid moisture analyzer: the moisture measurement range is 0%~100%. The reading accuracy is 0.01%. The weighing range is 0 g~30 g. The weighing accuracy is 1 mg. 5.2.3 Determination 5.2.3.1 Turn on the power and turn on the switch. Set the drying heating temperature to 105°C and the heating time to automatic. The result is expressed in the range of 0%~100%. 5.2.3.2 Open the sample chamber cover. Take a sample pan and place it on the balance frame of the infrared moisture analyzer, and return it to zero. 5.2.3.3 Take out the sample pan. Spread approximately 5 g of the sample prepared according to 5.1.4.1 evenly on the plate. Put it back into the sample room. 5.2.3.4 Cover the sample chamber cover. Start heating. After drying is complete, read the moisture content on the digital display. When equipped with a printer, the moisture content can be automatically printed. 5.3 Result calculation 5.3.1 The moisture content of non-frozen samples is calculated according to formula (1): Where, X - moisture content of non-frozen samples, in grams per hundred grams (g/100 g); m0 - total mass of the weighing vessel, thin glass rod and sand after drying, in grams (g); m1 - total mass of the meat, weighing vessel, fine glass rod and sand before drying, in ......

BASIC DATA
Standard ID GB 18394-2020 (GB18394-2020)
Description (Translated English) Permitted level of moisture in meat of livestock and poultry
Sector / Industry National Standard
Classification of Chinese Standard X22
Classification of International Standard 67.120.10
Word Count Estimation 5,568
Date of Issue 2020-12-24
Date of Implementation 2022-01-01
Older Standard (superseded by this standard) GB 18394-2001
Quoted Standard GB 5009.3-2016; GB/T 6682; GB/T 19480
Drafting Organization China Animal Disease Prevention and Control Center (Slaughter Technology Center of the Ministry of Agriculture and Rural Affairs)
Administrative Organization Ministry of Agriculture and Rural Affairs of the People's Republic of China
Regulation (derived from) National Standard Announcement No. 31 of 2020
Proposing organization Ministry of Agriculture and Rural Affairs of the People's Republic of China
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration
Summary This standard specifies the moisture limit index and test method for livestock and poultry meat. This standard applies to fresh (frozen) pork, beef, mutton and chicken.

BASIC DATA
Standard ID GB 18394-2001 (GB18394-2001)
Description (Translated English) Permitted level of moisture in meat of livestock and poultry
Sector / Industry National Standard
Classification of Chinese Standard X22
Word Count Estimation 5,518
Date of Issue 2001-07-20
Date of Implementation 2001-12-01
Quoted Standard GB/T 9695.15-1988; GB/T 9695.19-1988
Drafting Organization State Internal Trade Bureau meat, eggs and Food Quality Inspection Center (Beijing)
Proposing organization National Bureau of Internal Trade
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China
Summary This Chinese standard specifies the poultry meat moisture limit indicators, measuring methods and other requirements. This standard applies to fresh and frozen pork, beef, lamb and chicken.