HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GA 124-2013 English PDF

GA 124: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 124-2013English1039 Add to Cart 5 days [Need to translate] Self-contained positive pressure air breathing apparatus for fire-fighting Obsolete GA 124-2013
GA 124-2004English439 Add to Cart 3 days [Need to translate] Self-contained positive pressure air breathing apparatus for fire fighter Obsolete GA 124-2004
GA 124-1996English399 Add to Cart 3 days [Need to translate] (Positive pressure type fire - fighting air respirator) Obsolete GA 124-1996

PDF similar to GA 124-2013


Standard similar to GA 124-2013

GA 10   GA 602   GB 21976.7   

Basic data

Standard ID GA 124-2013 (GA124-2013)
Description (Translated English) Self-contained positive pressure air breathing apparatus for fire-fighting
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C85
Classification of International Standard 13.220.10
Word Count Estimation 25,248
Date of Issue 2013-07-26
Date of Implementation 2013-09-01
Older Standard (superseded by this standard) GA 124-2004
Quoted Standard GB/T 1226-2010; GB/T 2410-2008; GB 2890-2009; GB 3836.1-2010; GB 3836.4-2010; GB/T 7307-2001; GB 28053-2011
Adopted Standard EN 137-2006, NEQ; NFPA 1981-2007, NEQ
Regulation (derived from) Positive Pressure Fire Air Respirator industry standard revised release; industry standard filing notice 2014 No. 4 (total 172)
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the type, series, technical requirements, test methods, inspection rules, signs, packaging, transportation and storage of positive pressure type fire breathing air respirator. This standard applies to gas cylinders nominal working

GA 124-2013: Self-contained positive pressure air breathing apparatus for fire-fighting

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Self-contained positive pressure air breathing apparatus for fire-fighting ICS 13.220.10 C85 People's Republic of China Public Security Industry Standards Replacing GA 124-2004 Positive pressure firefighting air respirator Issued on. 2013-07-26 2013-09-01 implementation People's Republic of China Ministry of Public Security

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 models, Series 2 4.1 Part 2 4.2 Series 2 5 2 Technical Requirements 5.1 General 2 5.2 Structural requirements 2 5.3 Material Requirements 3 5.4 Quality wear 3 5.5 overall airtight performance 3 5.6 dynamic respiratory resistance 3 5.7 temperature performance 3 5.8 low temperature performance 4 5.9 Thermal radiation resistant performance 4 5.10 static pressure of 4 5.11 sirens performance 4 5.12 full face mask performance 4 Performance 5.13 4 Regulator 5.14 safety valve performance 5 5.15 for the valve performance 5 5.16 gauge 5 5.17 Pressure head-up display device 5 5.18 connection strength 6 The strength of the high-pressure part 6 5.19 5.20 6 airway pressure Push-in fitting 6 5.21 5.22 7 cylinders 5.23 cylinder valves 7 5.24 practical performance 8 6 Test methods 8 6.1 General 8 Visual inspection 8 6.2 6.3 flame retardancy test 8 6.4 heat aging performance test 9 6.5 Determination of wearing quality 9 6.6 overall airtight performance test 9 6.7 Determination of dynamic respiratory resistance 10 6.8 10 high temperature performance test 6.9 Low temperature resistance test 10 6.10 radiation-resistant thermal performance test 10 6.11 static pressure measurement 11 6.12 Performance Test Siren 11 6.13 Performance test full-face mask 11 Regulator performance test 11 6.14 6.15 safety valve performance test 11 6.16 Performance test gauge 12 6.17 Pressure head-up display device performance test 12 6.18 connection strength test 12 6.19 12 high-voltage components strength test 6.20 airway pressure test 13 6.21 quick coupling 13 Test 6.22 Test cylinders 14 6.23 Test cylinder valve 14 6.24 Practical Performance Test 14 7 Inspection rules 15 7.1 factory inspection 15 15 7.2 Type inspection 8 signs, packaging, transportation and storage 17 8.1 Marking 17 8.2 Packaging 17 8.3 Transport 17 8.4 Storage 17 Appendix A (normative) rapid inflation means 18 Appendix B (normative) ambient air bypass means 20 Annex C (normative) remote call device 21

Foreword

The standard of 5.2 to 5.24, Chapter 7, 8.1, 8.2 for the mandatory provisions, the rest are recommended provisions. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GA 124-2004 "positive pressure firefighting air respirator." Compared with GA 124-2004, major technological changes as follows. --- Modify the establishment, the division series models (see Chapter 4, Chapter 4 of the 2004 edition); --- General increased (see 5.1); --- Modify the structural requirements (see 52, 2004 version 5.1.); --- Increased back tools, cylinders protective sleeve retardant performance requirements (see 5.3.1.1); --- Increased heat aging performance requirements and test methods (see 5.3.2,6.4); --- Increased radiation-resistant thermal performance requirements and test methods (see 5.9,6.10); --- Revised aerodynamic sirens performance requirements (see 51111, 2004 edition of 5.9.1...); --- Electronic siren increased performance requirements (see 5.11.2); --- Revised comprehensive cover performance requirements (see 512, 2004 edition 5.10.); --- Modify the gauge pointer performance requirements (see 5161, 2004 version 5.14.); --- Increased electronic gauge performance requirements (see 5.16.2); --- Increasing the pressure level of performance requirements and test methods for the device (see 5.17,6.17) visual display; --- Increasing the connection strength requirements and test methods (see 5.18,6.18); --- Increased requirements and test methods for non-metallic high-pressure parts strength (see 5.19.2,6.19.2); --- Modify the performance requirements and test methods airway pressure (see 520, 620, 2004 edition of 5.16,6.15.); --- Increased requirements and test methods for quick coupling (see 5.21,6.21); --- Modified cylinder requirements (see 522, 2004 version 5.17.); --- Modify the output of the cylinder valve size requirements (see 5233, 2004 edition of 5.18.4.); --- Modify the practical performance requirements and test methods (see 524, 624, 2004 edition of 5.19,6.18.); --- Modified high temperature performance test methods (see 68, 2004 version 6.6.); --- Modify the inspection rules (see Chapter 7, Chapter 7 of the 2004 edition); --- Modify the marking requirements (see 81, 2004 version 8.1.); --- Increased performance requirements and test methods for fast inflatable device (see Appendix A); --- Increased performance requirements and test methods for ambient air bypass device (see Appendix B); --- Increased performance requirements and test methods for long-distance call device (see Appendix C). The reference to the standard EN137.2006 "Respiratory protective devices with full facepiece self-contained open-circuit compressed air breathing apparatus - Requirements, testing And signs "(in English) and NFPA1981.2007" with an open fire and emergency self-contained breathing (SCBA) ". This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee firefighters Fire Protection Equipment Technical Committee (SAC/TC113/SC12) centralized. This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security. The main drafters of this standard. Ling Xinliang, Bi win, Shen Jian Min, Huang Hui, Yang Xiaohua, Douchy, Zhangshou Zheng, Yao Haifeng, LIU Ruimin, Lee New Year. This standard replaces the standards previously issued as follows. --- GA 124-1996; --- GA 124-2004. Positive pressure firefighting air respirator

1 Scope

This standard specifies the positive pressure firefighting air respirator model, series, technical requirements, test methods, inspection rules and signs, packaging, Transportation and storage. This standard applies to nominal working pressure cylinders, 30MPa positive pressure firefighting air respirator. This standard does not apply to oxygen breathing apparatus, scuba diving, and a negative pressure air respirator with escape SCBA.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1226-2010 General Pressure Gauge Determination of GB/T 2410-2008 transparent plastic light transmittance and haze GB 2890-2009 respiratory protective self-absorption filter respirators GB 3836.1-2010 explosive atmospheres - Part 1. General requirements for equipment GB 3836.4-2010 Explosive atmospheres - Part 4. the intrinsically safe "i" protection equipment GB/T 7307-2001 55 ° non-sealing pipe thread GB 28053-2011 respirator composite cylinders

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 A respirator apparatus used by firefighters, the use of a respirator mask and the face of the wearer surrounding adhesion, so that the wearer respiratory organs, eyes and Face with the outside air or exposed to hypoxic environment completely isolated, with a source of compressed air supplied to the wearer's own breathing used in clean air exhaled Gas directly into the atmosphere, either respiratory cycle, pressure in the mask are greater than ambient pressure. 3.2 Static pressure staticpressure After a positive pressure for the valve means to open, pressure in the mask when the system air balanced. 3.3 High-voltage part high-pressurecomponent Direct output to withstand high pressure cylinder pressure parts. 3.4 MV airway medium-pressureairduct Withstand pressure reducer output pressure airway. 3.5 Inspiratory resistance inhalationresistance Pressure in the mask values breathing.