Path:
Home >
SN/T >
Page26 > SN/T 4559-2016
Price & Delivery
US$229.00 · In stock · Download in 9 secondsSN/T 4559-2016: Textiles import and export--Determination of adipate esters--Gas chromatography-mass spectrometry method
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| SN/T 4559-2016 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Textiles import and export--Determination of adipate esters--Gas chromatography-mass spectrometry method
|
Click to Preview a similar PDF
Basic data
| Standard ID | SN/T 4559-2016 (SN/T4559-2016) |
| Description (Translated English) | Textiles import and export--Determination of adipate esters--Gas chromatography-mass spectrometry method |
| Sector / Industry | Commodity Inspection Standard (Recommended) |
| Classification of Chinese Standard | W55 |
| Word Count Estimation | 10,162 |
| Date of Issue | 2016-08-23 |
| Date of Implementation | 2017-03-01 |
| Regulation (derived from) | State-Quality-Inspection-Accredidation (2016) No.438 |
| Issuing agency(ies) | General Administration of Customs |
SN/T 4559-2016: Textiles import and export--Determination of adipate esters--Gas chromatography-mass spectrometry method
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Textiles import and export--Determination of adipate esters--Gas chromatography-mass spectrometry method
China's entry-exit inspection and quarantine industry standards
Determination of adipic acid in textiles for import and export
Gas chromatography-mass spectrometry
Published on.2016-08-23
2017-03-01 Implementation
China
The State Administration of Quality Supervision, Inspection and Quarantine issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed and managed by the National Certification and Accreditation Regulatory Commission.
This standard was drafted by the People's Republic of China Xinjiang Entry-Exit Inspection and Quarantine Bureau and the People's Republic of China Shandong Entry-Exit Inspection Inspection
Epidemic Bureau.
The main drafters of this standard. Liu Jun, Wang Xiaoping, Liu Sicong, Zhu Xia, Ma Zengmei, Li Jiang, Niu Zengyuan, Zhang Xulong.
Determination of adipic acid in textiles for import and export
Gas chromatography-mass spectrometry
Warnings - Persons using this document should have practical experience in regular laboratory work. This document does not indicate all possible safety issues
question. It is the user's responsibility to take appropriate safety and health measures and to ensure compliance with the conditions stipulated by relevant national laws and regulations.
1 Scope
This standard specifies the method of gas chromatography-mass spectrometry to determine the content of adipic esters in textiles.
This standard applies to the determination of adipic acid content in textiles.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article
Pieces. For undated references, the latest edition (including the amendments used) applies to this document.
GB/T 6682 Analysis Laboratory Water Specifications and Test Methods
GB/T 8170 Representation and Judgment of Digital Roughness Rules and Limit Values
3 Principle
The sample was extracted by ultrasonic extraction with dichloromethane. After constant volume, the sample solution was detected by gas chromatography-mass spectrometry and determined by full-scan detection.
Sex, external ion standardization with selected ions.
4 Reagents and materials
Unless otherwise specified, all reagents are of analytical grade and water is deionized water according to GB/T 6682.
4.1 Dichloromethane. Chromatographically pure.
4.2 n-hexane. chromatographic purity.
4.3 Adipic acid standards. Purity ≥98%, diethyl adipate, diisobutyl adipate, dibutyl adipate, di-2-ethyl adipate
Hexyl esters and bis (2-butoxyethyl) adipate (English name, chemical abstract number and molecular formulae see Appendix A).
4.4 standard stock solution. Weigh the appropriate amount of adipic acid standard product (4.3) (accurate to 0.1mg), and make it to 1000μg/L with n-hexane.
The stock solution, standard stock solution in the refrigerator at 0 °C ~ 4 °C protected from light, the standard stock solution storage period of 6 months.
4.5 Standard working solution. Take appropriate amount of standard stock solution of various adipic acid esters (4.4), dilute with dichloromethane if necessary to use for suitable mixing
The standard working solution and standard working solution are stored in the refrigerator at 0°C~4°C from light. The standard working solution has a shelf life of 1 month.
5 Instruments
5.1 Gas Chromatography-Mass Spectrometer (GC-MS). Equipped with Electron Impact Ionization (EI).
5.2 Balance. The amount of sense is 0.01g.
5.3 Ultrasonic generator. 300W, operating frequency 40kHz.
...