HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YY/T 0735.2-2010 English PDF

US$194.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0735.2-2010: Anaesthetic and respiratory equipment. Heat and moisture exchangers (HMEs) for humidifying respired gases in humans. Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250ml
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 0735.2-2010English194 Add to Cart 3 days [Need to translate] Anaesthetic and respiratory equipment. Heat and moisture exchangers (HMEs) for humidifying respired gases in humans. Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250ml Valid YY/T 0735.2-2010

PDF similar to YY/T 0735.2-2010


Standard similar to YY/T 0735.2-2010

YY/T 0636.1   YY/T 0799   YY 0671.1   YY/T 0339   YY/T 0753.2   YY/T 0735.1   

Basic data

Standard ID YY/T 0735.2-2010 (YY/T0735.2-2010)
Description (Translated English) Anaesthetic and respiratory equipment. Heat and moisture exchangers (HMEs) for humidifying respired gases in humans. Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250ml
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C46
Classification of International Standard 11.040.10
Word Count Estimation 10,189
Date of Issue 2010-12-27
Date of Implementation 2012-06-01
Quoted Standard GB/T 4999-2003; GB/T 16273.1-2008; GB 19633; YY 1040.1-2003; YY 1040.2-2008; YY/T 0735.1-2009
Adopted Standard ISO 9360-2-2001, IDT
Regulation (derived from) State Food and Drug Administration Notice 2010 No. 97
Issuing agency(ies) State Food and Drug Administration
Summary This standard provides no mechanical connection port HME, including even as one of the breathing system filters specific requirements and test methods. These devices are used for more than 250mL tidal volume tracheostomy patient's respiratory gas humidification.

YY/T 0735.2-2010: Anaesthetic and respiratory equipment. Heat and moisture exchangers (HMEs) for humidifying respired gases in humans. Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250ml



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Anaesthetic and respiratory equipment.Heat and moisture exchangers (HMEs) for humidifying respired gases in humans.Part 2. HMEs for use with tracheostomized patients having minimum tidal volumes of 250ml ICS 11.040.10 C46 People's Republic of China pharmaceutical industry standards Anaesthetic and respiratory equipment For humidifying the human respiratory gas heat and moisture exchanger (HMEs) - Part 2. for tracheostomy 250mL tidal volume than patients HMEs Anaestheticandrespiratoryequipment-Heatandmoistureexchangers (HMEs) forhumidifyingrespiredgasesinhumans-Part 2. HMEsforusewith (ISO 9360-2.2001, IDT) Issued on. 2012-06-01 2010-12-27 implementation State Food and Drug Administration issued

Foreword

YY/T 0735 the general title "Anaesthetic and respiratory equipment for respiratory gas humidification body heat and moisture exchangers (HMEs)", including The following sections. --- Part 1. For a minimum tidal volume of 250mL of HME; --- Part 2. tracheostomy for patients with more than 250mL tidal volume HMEs. This section YY/T Section 20735 of. This section drafted in accordance with GB/T 1.1-2009 given rules. This section identical with the international standard ISO 9360-2. HME 2001 "Anaesthetic and respiratory equipment for humidifying the human respiratory gases Device (HMEs) - Part 2. for tracheostomy patients over 250mL tidal volume HMEs ". This section and ISO 9360-2.2001 as compared to the major differences include. --- Remove the ISO 9360-2.2001 Foreword in the part. ISO international standard --- referenced in this section, have been adopted as the corresponding national standards and industry standards, this section to refer to these National standards and industry standards as the standard use, no correspondence now been adopted as national standards and industry standards, places cited ISO international standards as the standard use. This standard requires certain basic principles are given in Appendix A. These provisions are shown in the text by (R). This part of the National Standardization Technical Committee on Narcotic breathing apparatus and (SAC/TC116) centralized. This part by the Shanghai Medical Device Testing is responsible for drafting. The main drafters of this section. Wang Wei, Li Min. Anaesthetic and respiratory equipment For humidifying the human respiratory gas heat and moisture exchanger (HMEs) - Part 2. for tracheostomy 250mL tidal volume than patients HMEs

1 Scope

YY/T 0735 based in part on the present YY/T 0735.1-2009, provides no mechanical connection port HME comprising even as Specific requirements and test methods for respiratory filters one. These devices are used for more than 250mL tidal volume tracheotomy patients By respiratory gas humidification.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 4999-2003 term anesthesia breathing equipment (1SO4135.2001, IDT) GB/T 16273.1-2008 equipment - Graphical symbols - Part 1. Common symbols (ISO 7000.2004, NEQ) GB 19633 Packaging for terminally sterilized medical devices (GB 19633-2005, ISO 11607.2003, IDT) YY 1040.1-2003 anesthesia and respiratory equipment - Conical fittings - Part 1. cone and sleeve (ISO 5356-1.1996, IDT) YY 1040.2-2008 anesthesia and respiratory equipment - Conical fittings - Part 2. Screw load-bearing joints (ISO 5356-2.2006, IDT) YY/T 0735.1-2009 anesthesia equipment and respiratory gas humidification human respiratory heat and moisture exchanger (HME) - Part 1. The minimum tidal volume of 250mL of HME (ISO 9360-1.2000, IDT)

3 Terms and Definitions

GB/T 4999-2003 and YY/T 0735.1-2009 defined and the following terms and definitions apply to this document. 3.1 (R) HME internal volume HMEinternalvolume HME The HME volume minus the volume of all solid ingredients, minus the volume of all the inner conical joint remaining volume. In the case of non-compressed, HME in volume by an inner surface and a boundary surface HME theory impermeable material composition, the edge The minimum surface area of the interface is closed HME active ingredient.

4 Symbols and Abbreviations

Symbol YY/T 0735.1-2009 and abbreviations given in the application of this document.

5 General requirements and recommendations

5.1 (R) HME patient port connector Patient connector port should be able to comply with the YY 1040.1-2003 15mm outer conical connector mating.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0735.2-2010_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0735.2-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0735.2-2010_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0735.2-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.