YY 0671-2021English619 Add to Cart 5 days (Medical equipment sleep apnea treatment mask and application accessories) Valid
YY/T 0671-2021English569 Add to Cart 5 days Medical devices-Sleep apnoea breathing therapy- Masks and application accessories Valid
YY 0671.1-2009English150 Add to Cart 0-9 seconds. Auto-delivery. Sleep apnoea breathing therapy. Prat 1: Sleep apnoea breathing therapy devices Obsolete
Newer version: YY 0671-2021     Standards related to (historical): YY 0671-2021
PDF Preview

YY 0671.1-2009: PDF in English

YY 0671.1-2009 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.10 C 46 Sleep apnoea breathing therapy – Part 1. Sleep apnoea breathing therapy devices (ISO 17510-1.2002, MOD) ISSUED ON. JUNE 16, 2009 IMPLEMENTED ON. DECEMBER 1, 2010 Issued by. China Food and Drug Administration 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes. Table of Contents Foreword ... 6  Introduction ... 8  1 Scope* ... 9  2 Terms and definitions ... 10  3 General requirements ... 13  4 Test general requirements ... 13  5 Classification ... 13  6 Identification, marks and files ... 13  7 Input power ... 17  8 Basic safety type ... 17  9 Removable protective device ... 17  10 Ambient conditions ... 17  11 Not used ... 18  12 Not used... 18  13 Overview ... 18  14 Requirements for classification ... 18  15 Voltage and/or energy limits ... 18  16 Shell and enclosure ... 18  17 Isolation ... 19  18 Protection earthing, functional grounding and potential equalization ... 19  19 Continuous leakage current and patient auxiliary current ... 19  20 Dielectric strength ... 19  21 Mechanical strength ... 19  22 Moving parts ... 19  23 Face, corner and side ... 20  24 Certainty during normal use ... 20  25 Splash ... 20  26 Vibration and noise ... 20  27 Pneumatic and hydraulic power ... 21  28 Suspension ... 21  29 X-ray radiation ... 21  30 Α, β, λ neutron radiation and other particle radiation ... 21  31 Microwave radiation ... 21  32 Optical radiation (including laser) ... 22  33 Infrared radiation ... 22  34 Ultraviolet radiation ... 22  35 Sound energy (including ultrasound) ... 22  36 Electromagnetic compatibility ... 22  37 Location and basic requirements ... 22  38 Signs, random files ... 22  39 Common requirements for AP and APG devices ... 22  40 Requirements and tests for AP device and its components and elements 23  41 Requirements and tests for APG device and its components and elements ... 23  42 Over-temperature ... 23  43* Fire protection ... 23  44 Overflow, liquid spill, leak, moisture, liquid injection, cleaning, disinfection, sterilization and compatibility ... 24  45 Pressure vessel and pressured parts ... 24  46 Not used... 24  47 Static charge ... 24  48 Biocompatibility ... 25  49 Power supply interruption... 25  50 Accuracy of work data ... 25  51 Hazardous output prevention ... 25  52 Abnormal operation and fault status ... 26  53 Ambient test ... 26  54 Overview ... 26  55 Shell and enclosure ... 27  56 Components and elements ... 27  57 Network power parts, components and wiring ... 30  58 Protective ground - terminals and connections ... 30  59 Structure and wiring ... 30  Annex ... 30  Annex A (Informative) Basic principles ... 31  Annex B (Informative) Glossary ... 37  Bibliography ... 38  Foreword YY 0671 Sleep apnoea breathing therapy consists of the following parts. -- Part 1. Sleep apnoea breathing therapy devices; -- Part 2. Masks and application accessories. This Part is the first part of YY 0671. The modification of this Part uses the International Standard ISO 17510-1.2002 Sleep apnoea breathing therapy -- Part 1. Sleep apnoea breathing therapy devices. The main difference between this Part and ISO 17510-1.2002 is as follows. This Part modified Clause 2 “Normative references” of ISO 17510-1.2002 to sub-clause 1.101, Clause 3 “Terms and definitions” to Clause 2, so as to be consistent with the common standard number. This Part is a special standard based on GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (a general standard). It shall be used together with GB 9706.1-2007. Clause 36 Electromagnetic compatibility of this Part shall be implemented concurrently with YY 0505-2005 (IEC 60601-1-2.2001, IDT) Medical electrical equipment - Part 1-2. General requirements for safety - Collateral standards. Electromagnetic compatibility - Requirements and tests. Clause 56 of this Part referred to EN 556 Sterilization of medical devices. Requirements for medical devices to be designated "STERILE", PrEN 737-6.1998 Medical gas pipeline systems - Part 6. Dimensions of probes for terminal units for compressed medical gases and vacuum, EN 739 Low-pressure hose assemblies for use with medical gases, EN ISO 8185 Humidifiers for medical use - General requirements for humidification systems, EN ISO 9360-1 Anaesthetic and respiratory equipment -- Heat and moisture exchangers (HMEs) for humidifying respired gases in humans -- Part 1. HMEs for use with minimum tidal volumes of 250 ml. It shall be implemented concurrently with these standards after they are converted to national or industry standards. It shall be explained in the preparation instructions. Annex AA and Annex BB of this Part are informative. This Part was proposed by a... ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.