US$279.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY 1040.2-2008: Anaesthetic and respiratory equipment. Conical connectors. Part 2: Screw-threaded weight-bearing connectors Status: Obsolete
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YY 1040.2-2008 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Anaesthetic and respiratory equipment. Conical connectors. Part 2: Screw-threaded weight-bearing connectors
| Obsolete |
YY 1040.2-2008
|
PDF similar to YY 1040.2-2008
Basic data | Standard ID | YY 1040.2-2008 (YY1040.2-2008) | | Description (Translated English) | Anaesthetic and respiratory equipment. Conical connectors. Part 2: Screw-threaded weight-bearing connectors | | Sector / Industry | Medical Device & Pharmaceutical Industry Standard | | Classification of Chinese Standard | C46 | | Classification of International Standard | 11.040.10 | | Word Count Estimation | 7,785 | | Date of Issue | 2008-10-17 | | Date of Implementation | 2010-06-01 | | Quoted Standard | GB/T 9145-2003; YY 1040.1-2003 | | Adopted Standard | ISO 5356-2-2006, IDT | | Regulation (derived from) | SFDA [2008] No. 605 | | Issuing agency(ies) | State Food and Drug Administration | | Summary | This standard provides for inhalation anesthesia equipment and ventilator bearing tapered threaded joints requirements, these connectors are for heavy equipment attachments. |
YY 1040.2-2008: Anaesthetic and respiratory equipment. Conical connectors. Part 2: Screw-threaded weight-bearing connectors ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Anaesthetic and respiratory equipment.Conical connectors.Part 2. Screw-threaded weight-bearing connectors
ICS 11.040.10
C46
People's Republic of China pharmaceutical industry standards
YY 1040.2-2008/ISO 5356-2.2006
Anaesthetic and respiratory equipment conical fitting
Part 2. load-bearing joints thread
(ISO 5356-2.2006, IDT)
Posted 2008-10-17
2010-06-01 implementation
State Food and Drug Administration issued
Foreword
YY 1040 "Anaesthetic and respiratory equipment cone joint," consists of the following components.
--- Part 1. Cones and sockets;
--- Part 2. threaded bearing joints.
This is Part 2 YY 1040 of.
This section identical with the international standard ISO 5356-2.2006 "anesthesia and respiratory equipment - Conical fittings - Part 2. load-bearing thread connection
head".
This part of ISO 5356-2.2006 as compared to the major differences are as follows.
--- ISO 5356-2.2006 Introduction The introduction of this standard conversion, delete ISO 5356-2.2006 Foreword;
--- ISO 5356-2. ISO 2006 international standard referenced, there is a corresponding been translated into national standards and industry standards, in order to lead this part
Use these national standards and industry standards as the norm; now no correspondence has been adopted as national standards and industry standards, places cited
With international standards as ISO standard use.
This part of the National Standardization Technical Committee of anesthesia and respiratory equipment and focal points.
This section is drafted. Shanghai Medical Device detection.
The main drafters of this section. Wang Wei, Yu Hung Yi.
YY 1040.2-2008/ISO 5356-2.2006
Introduction
Although the conical fitting YY 1040.1-2003 described can be used to connect the light breathing attachment, however, support for heavy or fragile
Accessories need to be more robust joint. These factors include the joint design strength, simple, easy sterilization, easy connection and removal by hand.
These fittings should also be compatible with the requirements of the joint accord YY 1040.1, and, although prior to use to check whether the system is installed correctly
Is the user's responsibility, these joints should also try to avoid the possibility of accidental wrong connection.
Thread the load-bearing joints YY 1040 described in this section may be used for attachment in the respiratory system and the common gas outlet.
YY 1040.2-2008/ISO 5356-2.2006
Anaesthetic and respiratory equipment conical fitting
Part 2. load-bearing joints thread
1 Scope
YY 1040 This section specifies requirements for inhalation anesthesia equipment and ventilators bearing cone threaded connectors, these connectors
Used heavy equipment attachments.
2 Normative references
The following documents contain provisions which, through reference YY 1040 of this section and become part of the standard terms and conditions. For dated references
Documents, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Research into whether the parties to the agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 9145-2003 common thread moderate accuracy, limit the size of the preferred series (ISO 965-2.1998, MOD)
YY 1040.1-2003 anesthesia and respiratory equipment - Conical fittings - Part 1. Cones and sockets (ISO 5356-1.1996, IDT)
3 Terms and Definitions
The following terms and definitions apply to this part YY 1040.
3.1
For dispensing and delivery of anesthetic gas and steam into the ventilation system of the device for delivery to the patient.
Note. According to GB/T 4999-2003 2.1.1 defined rewritten.
3.2
Improve the composition or component of a ventilation system.
Note. According to GB/T 4999-2003 4.1.6 defined rewritten.
3.3
During ventilation in any form, in contact with the patient's respiratory tract, for continuously or intermittently transporting gas passage.
1) In some cases, especially in the breathing machine, the port may be inside the device should not be installed as the interfaces of the ventilator housing elsewhere
Confused.
Note 1. In fact, the ventilation system typically extends from.
a) mixing the gas supply port 1), such as the common gas outlet anesthesia machine. or
b) the circulatory system of the fresh gas inlet, such as ventilators, T-tubes. or
c) a manual respirator fresh gas inlet.
Note 2. The ventilation system is usually extended to the gas mixture from the open end of the APL valve, T-shaped tube until the outlet air or gas purification system.
Note 3. connected to the gas purification system dedicated gas path can not be regarded as part of the ventilation system.
Note 4. According to GB/T 4999-2003 4.1.1 defined rewritten.
4 Design
Thread size bearing joint assembly shown in Figure 1.
YY 1040.2-2008/ISO 5356-2.2006
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY 1040.2-2008_English be delivered?Answer: Upon your order, we will start to translate YY 1040.2-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY 1040.2-2008_English with my colleagues?Answer: Yes. The purchased PDF of YY 1040.2-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|