YY 0635.2-2009: Inhalational anaesthesia systems. Part 2: Anaesthetic gas scavenging systems transfer and receiving systems
Status: Obsolete
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY 0635.2-2009English719 Add to Cart 4 days [Need to translate] Inhalational anaesthesia systems. Part 2: Anaesthetic gas scavenging systems transfer and receiving systems Obsolete YY 0635.2-2009

PDF similar to YY 0635.2-2009


Standard similar to YY 0635.2-2009

YY/T 0636.1   YY 0571   YY 0671.1   YY/T 0636.3   YY/T 0636.2   

Basic data

Standard ID YY 0635.2-2009 (YY0635.2-2009)
Description (Translated English) Inhalational anaesthesia systems. Part 2: Anaesthetic gas scavenging systems transfer and receiving systems
Sector / Industry Medical Device & Pharmaceutical Industry Standard
Classification of Chinese Standard C46
Classification of International Standard 11.040.10
Word Count Estimation 18,191
Date of Issue 2009-06-16
Date of Implementation 2010-12-01
Quoted Standard GB 9706.1-2007; GB/T 15608-2006; YY 1040.1-2003; YY 1040.2-2008; ISO 5359-2000
Adopted Standard ISO 8835-3-1997, IDT
Regulation (derived from) Industry standard filing Notice 2009 No. 9
Issuing agency(ies) State Food and Drug Administration
Summary This standard specifies the active anesthetic gas purification system (active AGSS) delivery and collection system requirements. This section also specifies the collection system and treatment system combines as one of the anesthetic gas purification system (AGSS) requirements. This section does not apply to passive anesthetic gas purification system (passive AGSS) or similar gases absorb system. This section does not include the requirement of two parts: a) separating a processing system, b) fixing treatment system installation. YY 0635 does not provide for this part such as gas exhaust port monitors and anesthesia gas purification systems (AGSS) connector.

YY 0635.2-2009: Inhalational anaesthesia systems. Part 2: Anaesthetic gas scavenging systems transfer and receiving systems


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Inhalational anaesthesia systems.Part 2. Anaesthetic gas scavenging systems transfer and receiving systems ICS 11.040.10 C46 People's Republic of China pharmaceutical industry standards YY 0635.2-2009/ISO 8835-3.1997 Inhalation anesthesia system Part 2. anesthetic gas purification system Delivery and collection system (ISO 8835-3.1997IDT) Posted 2009-06-16 2010-12-01 implementation State Food and Drug Administration issued

Table of Contents

Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 patients and protection of the environment 3 5 pressure release device 4 6 delivery system 4 7 collection system 4 8 Connector 4 9 draw traffic 5 10 Electrical requirements 5 11 information supplied by the manufacturer 5 12 numeral 5 5 13 Recognition Appendix A (normative) anesthetic gas purification system (AGSS) air inlet pressure rise test 7 Appendix B (normative) induction flow test 9 Annex C (normative) Test overflow 10 Annex D (normative) to draw flow resistance test 12 References 13 YY 0635.2-2009/ISO 8835-3.1997

Foreword

YY 0635 "inhalation anesthesia system" consists of the following components. --- Part 1. Adult anesthesia breathing systems; --- Part 2. anesthetic gas purification system delivery and collection system; --- Part 3. anesthetic gas delivery device; --- Part 4. anesthesia ventilator. This is Part 2 YY 0635 of. This part identical with ISO 8835-3.1997 "inhalation anesthesia systems - Part 3. anesthetic gas purification system delivery and collection system". This part of ISO 8835-3.1997 main differences are as follows. --- ISO 8835-3.1997 Introduction The conversion of the present introduction, delete ISO 8835-3.1997 Foreword; --- ISO 8835-3. ISO 1997 international standard referenced, has been adopted as the corresponding national standards and industry standards, in order to lead this part Use these national standards and industry standards as the norm; now no correspondence has been adopted as national standards and industry standards, places cited With international standards as ISO standard use; --- Because ISO 8835-3.1997 normative references in ISO 8835-1 standard only be referenced in the introductory part, and This partial deletion of the ISO 8835-3.1997 Foreword, therefore, this part of the normative references of this standard also deleted References; Over the same period to implement the provisions of international standards --- referenced in this section, to be the appropriate international standards into national or industry standards. This section of the Appendix A, Appendix B, Appendix C and Appendix D normative appendix. This part of the National Standardization Technical Committee of anesthesia and respiratory equipment and focal points. This section is drafted. Beijing Aerospace Changfeng Co., Ltd Medical Devices Branch. The main drafters of this section. Zhaopeng Li. YY 0635.2-2009/ISO 8835-3.1997

Introduction

It has been recognized that there are many factors beyond the anesthetic gas purification system (AGSS) manufacturers to control the impact of the operator's working environment Conditions, including room ventilation, equipment leaks and choice of anesthetic technique, all of which are uncertain. In addition, other factors also affect staff The total absorption of pollution, such as exposure time, the positional relationship between sources of pollution and the like. The purpose of this section is to ensure that all applications, anesthetic gas purification system (AGSS) purify it all leads will fundamentally Gas, thereby reducing air pollution to a very low level of non-controllable. Air pollution is the subject of anesthetic gases widely discussed, but due to criteria of environmental pollution is inconsistent, so This section is not recommended to allow purification indicators, there may be provisions in other standards. TC121 committee has been responsible for the first part of the participation restrictions anesthetic gas purification system (AGSS) delivery and collection systems due to Risk to the patient to change the function of the ventilation system caused. Now a wide range of commonly used anesthesia machine, ventilator and associated equipment Already under consideration. Generating means for limiting the use of anesthesia in the ventilation system of the gas purification system (AGSS) caused by pressure changes, and should Ventilation system or as close as possible in the ventilation system. Negative security assurances and induced flow is not easy, experience has shown that under certain conditions, anesthetic gas purification system (AGSS) any negative patient end can cause air flows from the ventilation system. Such air flow is very dangerous, for example, will Leading to the fresh gas flow rate is reduced to minimum flow rate required by the patient or less; composition changes lead to a gas mixture; and its influence break alarm His breathing is normal function measuring device or dangerous combinations of these. Because of the design in any condition can be prevented from introducing any flow from the ventilation system to the anesthetic gas purification system (AGSS) air inlet The collection system is very difficult to decide which provisions restricting flow. Induction flow and cautionary statements included in the requests for information This section, if applicable, provided by the manufacturer [(see 11b)]. Passive (passive) anesthetic gas purification system (passive AGSS) (for example. the air flow is not its processing system is generated by the power plant A) are not included in this section, because they do not meet safety requirements under all conditions specified. Adjacent gas suction system (for example. non Ventilation system directly connected to the system) is not included in this section. Therefore, this section is limited to active anesthetic gas purification system (active AGSS) delivery and collection systems, and integrated systems for collecting and processing systems anesthetic gas purification system (AGSS). Anesthetic gas purification system (AGSS) Examples of typical configuration shown in Figure 1. YY 0635.2-2009/ISO 8835-3.1997 Inhalation anesthesia system Part 2. anesthetic gas purification system Delivery and collection system

1 Scope

YY 0635 This section specifies the requirements for active anesthetic gas purification system (active AGSS) delivery and collection system. This section Also provides for collection systems and treatment system combines integrated anesthesia gas purification system (AGSS) requirements. This section does not apply to passive anesthetic gas purification system (passive AGSS) or similar gas suction system. This section does not include requirements for the following two parts. a) separating the processing system; b) mounting processing system. YY 0635 provisions of this section are not used as gas monitors anesthetic gas vent and purge systems (AGSS) connector; this Prescribed class joints are under consideration.

2 Normative references

The following documents contain provisions which, through reference YY 0635 present, constitute provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) GB 15608-2006 Chinese color system YY 1040.1-2003 anesthesia-respiratory conical fittings - Part 1. Cones and sockets (ISO 5356-1.1996, IDT) YY 1040.2-2008 anesthesia-respiratory conical fittings - Part 2. Screw load-bearing joints (ISO 5356-2.2006, IDT) ISO 5359.2000 Flexible low-pressure medical gas system used to connect hose assembly

3 Terms and Definitions

The following terms and definitions apply to this part YY 0635. 3.1 Driven by the drive unit of the gas flow anesthetic gas purification system (AGSS). 3.2 Used in anesthesia volatile gases and (or) vapor. 3.3 An exhaust port connected to the ventilation system or connection for complete outbound delivery and other equipment (or) to the appropriate excess anesthetic gas emissions at system. Note. From the functional point, a complete system consists of three parts. a delivery system, a collection system and a processing system. These three functional Separate each part can be separated and to be part of or connected together into a whole. Anesthetic gas purification system (AGSS) of part or parts can be To connect the ventilation system components or other devices. YY 0635.2-2009/ISO 8835-3.1997

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY 0635.2-2009_English be delivered?

Answer: Upon your order, we will start to translate YY 0635.2-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY 0635.2-2009_English with my colleagues?

Answer: Yes. The purchased PDF of YY 0635.2-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.