US$259.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0587-2018: Sterile dental injection needles for single use Status: Valid YY/T 0587: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YY/T 0587-2018 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
Sterile dental injection needles for single use
| Valid |
YY/T 0587-2018
|
YY 0587-2005 | English | 479 |
Add to Cart
|
3 days [Need to translate]
|
Sterile dental injection needles for single use
| Obsolete |
YY 0587-2005
|
PDF similar to YY/T 0587-2018
Standard similar to YY/T 0587-2018 YY 0585.4 YY 0585.2 YY/T 0586 YY/T 0581.2
Basic data Standard ID | YY/T 0587-2018 (YY/T0587-2018) | Description (Translated English) | Sterile dental injection needles for single use | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | Classification of Chinese Standard | C31 | Word Count Estimation | 13,170 | Date of Issue | 2018-04-11 | Date of Implementation | 2019-05-01 | Older Standard (superseded by this standard) | YY 0587-2005 | Regulation (derived from) | China Drug Administration Announcement No. 4 of 2018 | Issuing agency(ies) | State Drug Administration |
YY/T 0587-2018: Sterile dental injection needles for single use---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Disposable sterile dental needle)
ICS 11.040.20
C31
People's Republic of China Pharmaceutical Industry Standard
Replacing YY 0587-2005
Disposable sterile dental needle
(ISO 7885.2010, MOD)
Published on.2018-04-11
2019-05-01 implementation
State Drug Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces YY 0587-2005 "disposable sterile dental injection needle". Compared with YY 0587-2005, except for editorial repair
The main technical changes changed are as follows.
--- Revised the definition of "cylinder dental syringe" in Chapter 1, "Scope";
---Modified Figure 1 "Hard Packing Dental Needle Schematic";
---Modified the contents of the threaded needle type and marking example in Chapter 4, "Product Marking";
--- Move the type of Wyeth internal threaded hub in Chapter 4 "Product Marking" to Appendix C of this standard;
--- Increased the 0.2mm specification in Table 1;
--- Modified 6.6 tip;
--- Modified 7.3 extractable metal content;
--- Modified 8.3 bacterial endotoxin;
--- Removed the terms of the 10.3 User's Guide;
--- Removed the schematic diagram of Appendix A flow test device;
--- Revised the preparation of Appendix C biological test test solution;
--- Removed the Appendix D inspection rules.
This standard uses the redrafting method to modify the use of ISO 7885.2010 "disposable sterile dental needles."
The technical differences between this standard and ISO 7885.2010 and their reasons are as follows.
---About the normative reference documents, this standard has made technical adjustments to adapt to China's technical conditions, adjustments
The situation is reflected in Chapter 2, “Regulatory References”, and the specific adjustments are as follows.
● Replace ISO 9626 with GB/T 18457 modified to international standards (see Chapter 5);
● Added reference to GB/T 14233.1 (see 7.2, 7.3);
● Added reference to GB/T 14233.2 (see 8.2, 8.3);
● Replace ISO 10993-1 with GB/T 16886.1 equivalent to the international standard (see 8.2);
● Replace ISO 15233-1 (10.1, 10.2) with YY/T 0466.1, which is equivalent to the international standard;
● Added reference to GB/T 6682 (see Appendix B).
--- Added "Chapter 4 Product Marking" to standardize product marking requirements;
--- Added "6.6 first bevel angle of the puncture end" to clarify the requirements of the first bevel angle of the puncture end;
--- Added "6.3 pinhole smoothness";
--- Added "6.5.4 Needle tube characteristics", the needle tube characteristics are an important factor to investigate the safety performance of the needle tube material, thus increasing the needle tube
Sex indicator
--- Increased 7.2 "pH";
--- Added 8.3 "bacterial endotoxin".
This standard has made the following editorial changes.
--- Added Appendix B (normative appendix) "Preparation of chemical test solution";
--- Added Appendix C (Normative Appendix) "Preparation of Bacterial Endotoxin Test Solution".
Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents.
This standard was proposed by the State Drug Administration.
This standard is under the jurisdiction of the National Medical Syringe (Needle) Standardization Technical Committee (SAC/TC95).
This standard was drafted. Shanghai Kangdelai Enterprise Development Group Co., Ltd., Shanghai Medical Device Testing Institute.
The main drafters of this standard. Gao Yiqi, Hua Songhe.
The previous versions of the standards replaced by this standard are.
---YY 0587-2005.
Disposable sterile dental needle
1 Scope
This standard specifies the terms and definitions, requirements, packaging, marking and storage of disposable sterile dental injection needles (hereinafter referred to as dental needles).
Deposit requirements.
This standard applies to dental needles installed on dental card syringes conforming to the ISO 9997 standard for dental local anesthesia, but not
Dental needles for special applications and technologies.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 6682 Analytical laboratory water specifications and test methods (GB/T 6682-2008, ISO 3696.1987. MOD)
GB/T 14233.1-2008 Medical infusions, blood transfusions, injecting machines - Test methods - Part 1
GB/T 14233.2 Methods of test for infusions, blood trans
GB/T 16886.1 Biological evaluation of medical devices - Part 1. Evaluation and testing in the process of risk management (GB/T 16886.1-
2011, ISO 10993-1..2009, IDT)
GB/T 18457 Stainless steel needle tube for medical devices (GB/T 18457-2015, ISO 9626.1991/Amd.1.2001)
MOD)
YY/T 0466.1 Medical devices for use in medical devices - Labels, markings and information provided - Part 1 . General requirements
(YY/T 0466.1-2016, ISO 15233-1.2012, IDT)
ISO 9997 dental card syringe
The Pharmacopoeia of the People's Republic of China (2015 Edition)
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Needle unit needleunit
Main sheath, needle and needle holder (see Figure 1).
3.2
Effective needle length effectiveneedlelength
The length from the tip to the hub (see Figure 1).
3.3
Hard pack hardpack
The needle unit includes a rigid butt end sheath and a rigid piercing end sheath to form a sealed, unitary unit. (see picture 1).
3.4
Flexible packaging softpack
The needle unit contains a prefabricated plastic tray with a torn cover in which the puncture needle is protected by a rigid sheath.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0587-2018_English be delivered?Answer: Upon your order, we will start to translate YY/T 0587-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0587-2018_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0587-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YY/T 0587-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0587-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|