|
US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 990.13-2014: Methods for chemical analysis of copper mattee. Part 13:Determination of magnesium oxide content. Atomic absorption spectrmetry Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 990.13-2014 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of copper mattee. Part 13:Determination of magnesium oxide content. Atomic absorption spectrmetry
| Valid |
YS/T 990.13-2014
|
PDF similar to YS/T 990.13-2014
Basic data | Standard ID | YS/T 990.13-2014 (YS/T990.13-2014) | | Description (Translated English) | Methods for chemical analysis of copper mattee. Part 13��Determination of magnesium oxide content. Atomic absorption spectrmetry | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H13 | | Classification of International Standard | 77.120.30 | | Word Count Estimation | 7,718 | | Date of Issue | 10/14/2014 | | Date of Implementation | 4/1/2015 | | Regulation (derived from) | People's Republic of China Ministry of Industry and Information Technology Notice 2014 No. 63; Industry Standard Filing Notice 2014 No. 12 (Overall No. 180) | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This Standard specifies the method for determination of copper matte MgO content. This section applies to the determination of copper ice MgO content. Measured in the range of 0.10 to 6.00%. |
YS/T 990.13-2014: Methods for chemical analysis of copper mattee. Part 13:Determination of magnesium oxide content. Atomic absorption spectrmetry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of copper mattee Part 13. Determination of magnesium oxide content Atomic absorption spectrmetry.
ICS 77.120.30
H13
People's Republic of China Nonferrous Metals Industry Standard
Matte chemical analysis
Part 13. Determination of magnesium oxide content
Atomic Absorption Spectrometry
Part 13. Determinationofmagnesiumoxidecontent-
Issued on. 2014-10-14
2015-04-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 990 "Methods for chemical analysis of copper matte" is divided into 18 parts.
--- Part 1 Determination of copper content iodometry;
--- Part 2. Determination of gold and silver atomic absorption spectroscopy and fire assay;
--- Part 3. Determination of sulfur content - Gravimetric method and combustion titration method;
--- Part 4. Determination of the amount of bismuth atomic absorption spectrometry;
--- Part 5. Determination of the amount of fluorine ion selective electrode method;
--- Part 6. Determination of lead content - Atomic absorption spectrometry and Na2EDTA titration;
--- Part 7. Determination of cadmium content - Atomic absorption spectrometry;
--- Part 8. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry, diethyl dithiocarbamate spectrophotometry silver
And potassium bromate titration;
--- Part 9. Determination of iron content dichromate method;
--- Part 10. Determination of silicon dioxide content molybdenum blue spectrophotometry and silicon potassium fluoride titration;
--- Part 11. Determination of the amount of nickel atom absorption spectrometry;
--- Part 12. Determination of the amount of chromium oxide of aluminum Azure S Spectrophotometry;
--- Part 13. Determination of magnesium oxide content - Atomic absorption spectrometry;
--- Part 14. Determination of the amount of zinc atomic absorption spectrometry and Na2EDTA titration;
--- Part 15. Determination of antimony content - Atomic absorption spectrometry;
--- Part 16. Determination of mercury content - Cold atomic absorption spectrometry;
--- Part 17. Determination of the amount of cobalt atomic absorption spectrometry;
--- Part 18. lead, zinc, nickel, arsenic, bismuth, antimony, calcium, magnesium, cadmium, cobalt content - Inductively coupled plasma atomic emission spectrometry.
This section YS/T Part 13 990.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Zhongtiaoshan Nonferrous Metals Group Co., Ltd. Daye Nonferrous Metals Group Holdings Limited.
This section is drafted. Daye Nonferrous Metals Group Holdings Limited.
Participated in the drafting of this section. Beijing Nonferrous Metal Research Institute, Tongling Nonferrous Metals Group Holdings Co., Ltd., Yunnan Copper shares have
Ltd., Yu Teng Hunan Nonferrous Metals Co., Ltd., Tianjin, People's Republic of China Exit Inspection and Quarantine.
The main drafters of this section. Li Xiaoyu, Yuangong Qi, Wei Wen, Miss Li, Tong Ling, Li sweet, Han Juan, Mo Yu Qing, Zhang Zhao, Luo Yongmei, Wang,
Zheng Wenying, Li Xiaoping, Jiang Yuan for a long time.
Matte chemical analysis
Part 13. Determination of magnesium oxide content
Atomic Absorption Spectrometry
1 Scope
This section YS/T 990 specifies the method for determination of copper matte MgO content.
This section applies to the determination of copper ice MgO content. Determination of the range of 0.10 to 6.00%.
2 Method summary
Samples with hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid dissolved in dilute hydrochloric acid medium, adding a certain amount of strontium chloride interference suppression elements, use
Air - acetylene flame atomic absorption spectrometer wavelength 285.2nm at (adjust the angle of the burner), measuring the absorbance of magnesium oxide.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
3.1 hydrochloric acid (ρ = 1.19g/mL).
3.2 hydrochloride (11).
3.3 nitric acid (ρ = 1.42g/mL).
3.4 Hydrofluoric acid (ρ = 1.13g/mL).
3.5 perchloric acid (ρ = 1.67g/mL).
Standard stock solution 3.6 MgO. Magnesium oxide (wMgO≥99.99%) pre-ignition 1h at 600 ℃, placed in a desiccator to cool to room temperature.
Weigh 0.5000g of magnesium oxide in 250mL beaker, add a small amount of wetting water, added 20mL of hydrochloric acid (3.2) is completely dissolved and transferred to 500mL
Volumetric flask, dilute with water to volume, and mix. This solution 1mL 1mg containing magnesium oxide.
3.7 magnesium standard solution. Pipette 20.00mL magnesium accurate standard stock solution (3.6) in 100mL volumetric flask, was added 10mL
Hydrochloric acid (3.2), dilute to the mark and mix. This solution 1mL containing 200μg magnesia.
3.8 strontium chloride solution. Weigh 30.43g strontium chloride (SrCl2 · 6H2O) in 250mL beaker, add 30mL water, 25mL hydrochloric acid
(3.2) was dissolved and transferred to 500mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 20mg strontium.
3.9 Na2EDTA solution [c (Na2EDTA) ≈0.10mol/L]. Weigh 18.62g Disodium ethylenediaminetetraacetate (C10H14N2O8Na2 ·
2H2O), placed in 250mL beaker, after adding hot water dissolved and transferred to 500mL volumetric flask, dilute with water to volume, and mix.
4 Instrument
Atomic absorption spectrometer, with a magnesium hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Characteristic concentration. measurement solution with the matrix solution consistent characteristic concentration (appropriately adjusted burners corner), magnesium oxide should not be
Greater than 0.411μg/mL.
--- Precision. standard solution with the highest concentration of 11 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%;
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 990.13-2014_English be delivered?Answer: Upon your order, we will start to translate YS/T 990.13-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 990.13-2014_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 990.13-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|