US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 990.11-2014: Methods for chemical analysis of copper matte, Part 11: Determination of nickel content, Atomic absorption spectrmetry Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 990.11-2014 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of copper matte, Part 11: Determination of nickel content, Atomic absorption spectrmetry
| Valid |
YS/T 990.11-2014
|
PDF similar to YS/T 990.11-2014
Basic data | Standard ID | YS/T 990.11-2014 (YS/T990.11-2014) | | Description (Translated English) | Methods for chemical analysis of copper matte, Part 11: Determination of nickel content, Atomic absorption spectrmetry | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H13 | | Classification of International Standard | 77.120.30 | | Word Count Estimation | 7,772 | | Date of Issue | 10/14/2014 | | Date of Implementation | 4/1/2015 | | Regulation (derived from) | People's Republic of China Ministry of Industry and Information Technology Notice 2014 No. 63; Industry Standard Filing Notice 2014 No. 12 (Overall No. 180) | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This Standard specifies the method for determination of copper matte nickel content. This section applies to the determination of copper in ice nickel content. Measured in the range of from 0.05% to 1.00%. |
YS/T 990.11-2014: Methods for chemical analysis of copper matte, Part 11: Determination of nickel content, Atomic absorption spectrmetry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of copper matte, Part 11. Determination of nickel content, Atomic absorption spectrmetry
ICS 77.120.30
H13
People's Republic of China Nonferrous Metals Industry Standard
Matte chemical analysis
Part 11. Determination of nickel content
Atomic Absorption Spectrometry
Part 11. Determinationofnickelcontent-
Issued on. 2014-10-14
2015-04-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 990 "Methods for chemical analysis of copper matte" is divided into 18 parts.
--- Part 1. Determination of copper content iodometry;
--- Part 2. Determination of gold and silver atomic absorption spectroscopy and fire assay;
--- Part 3. Determination of sulfur content - Gravimetric method and combustion titration method;
--- Part 4. Determination of the amount of bismuth atomic absorption spectrometry;
--- Part 5. Determination of the amount of fluorine ion selective electrode method;
--- Part 6. Determination of lead content - Atomic absorption spectrometry and Na2EDTA titration;
--- Part 7. Determination of cadmium content - Atomic absorption spectrometry;
--- Part 8. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry, diethyl dithiocarbamate spectrophotometry silver
And potassium bromate titration;
--- Part 9. Determination of iron content dichromate method;
--- Part 10. Determination of silicon dioxide content molybdenum blue spectrophotometric method and silicon potassium fluoride titration;
--- Part 11. Determination of the amount of nickel atom absorption spectrometry;
--- Part 12. Determination of the amount of chromium oxide of aluminum Azure S Spectrophotometry;
--- Part 13. Determination of magnesium oxide content - Atomic absorption spectrometry;
--- Part 14. Determination of the amount of zinc atomic absorption spectrometry and Na2EDTA titration;
--- Part 15. Determination of antimony content - Atomic absorption spectrometry;
--- Part 16. Determination of mercury content - Cold atomic absorption spectrometry;
--- Part 17. Determination of the amount of cobalt atomic absorption spectrometry;
--- Part 18. lead, zinc, nickel, arsenic, bismuth, antimony, calcium, magnesium, cadmium, cobalt content - Inductively coupled plasma atomic emission spectrometry.
This section YS/T 990 Part 11.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Zhongtiaoshan Nonferrous Metals Group Co., Ltd. Daye Nonferrous Metals Group Holdings Limited.
This section drafted by. Smelting Co., Ltd. Hangzhou Fuchun River.
Participated in the drafting of this section. People's Republic of China Ningbo Exit Inspection and Quarantine, Yunnan Copper Co., Ltd., Tongling Nonferrous Metals
Metals Group Holdings Co., Ltd., Guangzhou Nonferrous Metal Research Institute, Beijing General Research Institute of Mining and Metallurgy, Lianyungang People's Republic of China Entry-Exit Inspection
Quarantine Bureau, Baiyin Nonferrous Group Co., Ltd.
The main drafters of this section. Zhang Liao, Jin Ling, Caoguo Zhou, Zhu Xiaoyan, Zheng Wenying, Li Ruiling, Cheng Haoyu, Pan Ying, Daniel Chan, Dai Fengying,
Liu Chunfeng, Shen Lin, Xia Xinyuan, Qin Lijun, Lv Yanling, Zhang Jinxia.
Matte chemical analysis
Part 11. Determination of nickel content
Atomic Absorption Spectrometry
1 Scope
This section YS/T 990 specifies the method for determination of copper matte nickel content.
This section applies to the determination of copper in ice nickel content. Measurement range of 0.05% to 1.00%.
2 Method summary
Samples with hydrochloric acid, nitric acid decomposition of sulfur removal with bromine, using air - acetylene flame atomic absorption spectrometer wavelength measured at 232.0nm
The amount of nickel absorbance standard curve method to calculate the amount of nickel.
3 Reagents
Unless otherwise described, used in the analysis only identified as analytical reagents, analysis of water, deionized water or equivalent purity.
3.1 ammonium hydrogen fluoride.
3.2 bromine.
3.3 hydrochloric acid (ρ = 1.19g/mL).
3.4 nitric acid (ρ = 1.42g/mL).
3.5 nitric acid (11).
3.6 Nickel standard stock solution. Weigh 0.5000g of nickel (wNi≥99.99%), placed in a beaker of 200mL, 10mL of nitric acid was added
(3.3), covered with a watch glass placed on a hot plate over low heat until completely dissolved, boiled to remove nitrogen oxides, cooled to room temperature. Moved to 1000mL
Volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 0.5mg nickel.
3.7 Nickel standard solution. Pipette 10.00mL Nickel standard stock solution (3.6) into 100mL volumetric flask, dilute with water to volume, and mix.
This solution 1mL containing 50μg nickel.
4 instruments and equipment
Atomic absorption spectrometer, with a nickel hollow cathode lamp.
In the atomic absorption spectrometer the best working conditions, who can be reached by the following indicators can be used.
--- Sensitivity. the substrate solution consistent with the measurement sample solution, characteristic concentration of nickel is not more than 0.05μg/mL;
--- Precision. standard solution with the highest concentration of 11 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%;
The absorbance measured 11 times the minimum concentration of the standard solution (not a "zero" standard solution), and the standard deviation should not exceed the maximum concentration
0.5% of the mean absorbance of the standard solution;
--- Linear calibration curves. the curve according to concentration divided into three segments, the difference between the absorbance of the absorbance difference between the highest and the lowest segment segment
The ratio shall be not less than 0.80.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 990.11-2014_English be delivered?Answer: Upon your order, we will start to translate YS/T 990.11-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 990.11-2014_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 990.11-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|