US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 990.12-2014: Methods of chemical analysis of copper matte.Part 12: Determination of aluminum oxide content.Spectrophotometry of chromazurol S Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 990.12-2014 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Methods of chemical analysis of copper matte.Part 12: Determination of aluminum oxide content.Spectrophotometry of chromazurol S
| Valid |
YS/T 990.12-2014
|
PDF similar to YS/T 990.12-2014
Basic data | Standard ID | YS/T 990.12-2014 (YS/T990.12-2014) | | Description (Translated English) | Methods of chemical analysis of copper matte.Part 12: Determination of aluminum oxide content.Spectrophotometry of chromazurol S | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H13 | | Classification of International Standard | 77.120.30 | | Word Count Estimation | 7,714 | | Date of Issue | 10/14/2014 | | Date of Implementation | 4/1/2015 | | Regulation (derived from) | People's Republic of China Ministry of Industry and Information Technology Notice 2014 No. 63; Industry Standard Filing Notice 2014 No. 12 (Overall No. 180) | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This Standard specifies the method for determination of copper matte aluminum oxide content. This section applies to the determination of copper in the ice of aluminum oxide content. Measured in the range of 0.20% to 1.00%. |
YS/T 990.12-2014: Methods of chemical analysis of copper matte.Part 12: Determination of aluminum oxide content.Spectrophotometry of chromazurol S ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods of chemical analysis of copper matte.Part 12. Determination of aluminum oxide content.Spectrophotometry of chromazurol S
ICS 77.120.30
H13
People's Republic of China Nonferrous Metals Industry Standard
Matte chemical analysis
Part 12. Three aluminum oxide contents -
Chromium Azure S Spectrophotometry
Part 12. Determinationofaluminumoxidecontent-
Issued on. 2014-10-14
2015-04-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 990 "Methods for chemical analysis of copper matte" is divided into 18 parts.
--- Part 1. Determination of copper content iodometry;
--- Part 2. Determination of gold and silver atomic absorption spectroscopy and fire assay;
--- Part 3. Determination of sulfur content - Gravimetric method and combustion titration method;
--- Part 4. Determination of the amount of bismuth atomic absorption spectrometry;
--- Part 5. Determination of the amount of fluorine ion selective electrode method;
--- Part 6. Determination of lead content - Atomic absorption spectrometry and Na2EDTA titration;
--- Part 7. Determination of cadmium content - Atomic absorption spectrometry;
--- Part 8. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry, diethyl dithiocarbamate spectrophotometry silver
And potassium bromate titration;
--- Part 9. Determination of iron content dichromate method;
--- Part 10. Determination of silicon dioxide content molybdenum blue spectrophotometric method and silicon potassium fluoride titration;
--- Part 11. Determination of the amount of nickel atom absorption spectrometry;
--- Part 12. Determination of the amount of chromium oxide of aluminum Azure S Spectrophotometry;
--- Part 13. Determination of magnesium oxide content - Atomic absorption spectrometry;
--- Part 14. Determination of the amount of zinc atomic absorption spectrometry and Na2EDTA titration;
--- Part 15. Determination of antimony content - Atomic absorption spectrometry;
--- Part 16. Determination of mercury content - Cold atomic absorption spectrometry;
--- Part 17. Determination of the amount of cobalt atomic absorption spectrometry;
--- Part 18. lead, zinc, nickel, arsenic, bismuth, antimony, calcium, magnesium, cadmium, cobalt content - Inductively coupled plasma atomic emission spectrometry.
This section YS/T Part 12 990.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.
This section is responsible for drafting unit. Zhongtiaoshan Nonferrous Metals Group Co., Ltd. Daye Nonferrous Metals Group Holdings Limited.
This section is drafted. Beijing Nonferrous Metal Research Institute.
Participated in the drafting of this section. Beijing Mining Research Institute, Fujian Zijin Mining Testing Technology Co., Ltd., Tongling Nonferrous Metals Group control
Holdings Limited, Baiyin Nonferrous Group Co., Ltd.
The main drafters of this section. Wang Tong Ling, Yang Hui, Liu Ying, Li sweet, Han Xiao, Chen hair, Zhongcui Lan, Wang Jinping, Zhang Zhao, Zheng provincial, show it.
Matte chemical analysis
Part 12. Three aluminum oxide contents -
Chromium Azure S Spectrophotometry
1 Scope
This section YS/T 990 specifies the method for determination of copper matte aluminum oxide content.
This section applies to the determination of ice copper aluminum oxide content. Measurement range of 0.20% to 1.00%.
2 Method summary
Sample sodium hydroxide, sodium peroxide melt, flooding, sedimentation separation to remove titanium, silver, copper, manganese and a lot of, respectively, with thiourea, ascorbic
Ascorbic acid masking remnants of copper, iron, vanadium eliminate interference with hydroxylamine hydrochloride in pH5.6 ~ 6.2 acetic acid - ammonium acetate buffer solution, aluminum and chromium
Azure S- octyl polyethylene glycol phenyl ether (emulsifier OP) forming a ternary complex, in the spectrophotometer at 650nm wavelength measured absorbance
Degrees, aluminum oxide content is calculated using the standard curve method. In a sample should not or low content of fluorine does not affect the color of aluminum.
3 Reagents
Unless otherwise specified, the reagents were analytical reagent solution preparation and analysis of water are secondary deionized water or equivalent purity
Of water.
3.1 sodium hydroxide.
3.2 sodium peroxide.
3.3 hydrochloric acid (ρ = 1.19g/mL).
3.4 hydrochloride (2mol/L).
3.5 hydrochloric acid (0.6mol/L).
3.6 hydrochloric acid (0.1mol/L).
3.7 Sodium hydroxide solution (200g/L).
3.8 Ammonia (2mol/L).
3.9 aqueous ammonia (0.1mol/L).
3.10 Thiourea (30g/L).
3.11 ascorbic acid solution (20g/L). Using now.
3.12 hydroxylammonium hydrochloride solution (100g/L). Using now.
3.13 Chromium Azure S solution. Weigh 0.2g Chromium Azure dissolved in 100mL anhydrous ethanol, diluted with water to 200mL, and mix.
3.14 Polyethylene glycol octylphenyl ether (emulsifier OP) solution (1499).
3.15 acetic acid - ammonium acetate buffer solution. A 485mL Ammonium acetate (4mol/L) and 15mL acetic acid (4mol/L) mixed (in preparation
4mol/L ammonium acetate solution should be adjusted to pH 7).
3.16 thymol blue solution (1g/L). Weigh 0.1g of thymol blue was dissolved in 50mL of absolute ethanol, diluted with water to 100mL,
Mix well.
3.17 aluminum standard stock solution. Weigh 0.1000g of aluminum (wAl≥99.99%) in 200mL beaker, add 50mL hydrochloric acid
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 990.12-2014_English be delivered?Answer: Upon your order, we will start to translate YS/T 990.12-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 990.12-2014_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 990.12-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|