US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 953.11-2014: Methods for chemical analysis of fire smelting neckel substrate material. Part 11: Determination of Lead, Arsenic, Cadmium and Mercury contents. Inductively coupled plasma-mass spectrometric method Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YS/T 953.11-2014 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of fire smelting neckel substrate material. Part 11: Determination of Lead, Arsenic, Cadmium and Mercury contents. Inductively coupled plasma-mass spectrometric method
| Valid |
YS/T 953.11-2014
|
PDF similar to YS/T 953.11-2014
Basic data Standard ID | YS/T 953.11-2014 (YS/T953.11-2014) | Description (Translated English) | Methods for chemical analysis of fire smelting neckel substrate material. Part 11: Determination of Lead, Arsenic, Cadmium and Mercury contents. Inductively coupled plasma-mass spectrometric method | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | H13 | Classification of International Standard | 77.120.40 | Word Count Estimation | 8,839 | Date of Issue | 10/14/2014 | Date of Implementation | 4/1/2015 | Quoted Standard | GB/T 6682; GB/T 20066 | Regulation (derived from) | People's Republic of China Ministry of Industry and Information Technology Notice 2014 No. 63; Industry Standard Filing Notice 2014 No. 12 (Overall No. 180) | Issuing agency(ies) | Ministry of Industry and Information Technology | Summary | This Standard specifies the determination pyrometallurgical nickel substrate compound of lead, arsenic, cadmium, mercury content by Inductively Coupled Plasma Mass Spectrometry. This section applies to feed lead, arsenic, cadmium, mercury content was meas |
YS/T 953.11-2014: Methods for chemical analysis of fire smelting neckel substrate material. Part 11: Determination of Lead, Arsenic, Cadmium and Mercury contents. Inductively coupled plasma-mass spectrometric method
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of fire smelting neckel substrate material Part 11. Determination of Lead, Arsenic, Cadmium and Mercury contents Inductively coupled plasma-mass spectrometric method
ICS 77.120.40
H13
People's Republic of China Nonferrous Metals Industry Standard
Methods for chemical analysis pyrometallurgical nickel substrate material
Part 11. lead, arsenic, cadmium and mercury contents -
Inductively Coupled Plasma Mass Spectrometry
Part 11. DeterminationofLead, Arsenic, CadmiumandMercurycontents-
Issued on. 2014-10-14
2015-04-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 953 "pyro-metallurgical materials for chemical analysis of nickel substrate" is divided into 11 parts.
--- Part 1. Determination of the amount of nickel dimethylglyoxime spectrophotometry and dimethylglyoxime gravimetric method;
--- Part 2. Determination of the amount of silicon silicon molybdenum blue spectrophotometric method and perchloric acid dehydration gravimetric method;
--- Part 3. Determination of phosphorus content of bismuth phosphorus molybdenum blue spectrophotometric method;
--- Part 4. Determination of chromium content ammonium ferrous sulfate titration;
--- Part 5. Determination of manganese content - Potassium periodate spectrophotometric method;
--- Part 6. Determination of cobalt content of 5-Cl-PADAB spectrophotometry and flame atomic absorption spectrometry;
--- Part 7. Determination of copper content bicyclic cyclohexanone oxalyl Spectrophotometric Method and flame atomic absorption spectrometry;
--- Part 8. Determination of iron content dichromate method;
--- Part 9. Carbon and sulfur content was measured high-frequency combustion infrared absorption method;
--- Part 10. nickel, chromium, manganese, cobalt, copper, phosphorus content - Inductively coupled plasma atomic emission spectrometry;
--- Part 11. lead, arsenic, cadmium, mercury content - Inductively Coupled Plasma Mass Spectrometry.
This section YS/T Part 11 953.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Zhongbao Binhai Nickel Industry Co., Ltd.
This section is drafted. Tianjin People's Republic of China Exit Inspection and Quarantine.
This section involved in the drafting unit. People's Republic of China Changshu Exit Inspection and Quarantine, Beijing Nonferrous Metal Research Institute, Chinese people
Republic Bayuquan Entry-Exit Inspection and Quarantine of Nantong People's Republic of China.
The main drafters of this section. Wang Haoyun, Li Yi, Hood new, new kingdom, ink Shumin, Jiang Xiaoguang, Dingju Xiang, Xu Yuyu, Liu Ying Plasture
Zhou Lu, Liu Min, Liu Huan.
Methods for chemical analysis pyrometallurgical nickel substrate material
Part 11. lead, arsenic, cadmium and mercury contents -
Inductively Coupled Plasma Mass Spectrometry
1 Scope
YS/T of the provisions of section 953 of the inductively coupled plasma mass spectrometry pyrometallurgical nickel substrate compound of lead, arsenic, cadmium, mercury content.
This section applies to compound of lead, arsenic, cadmium, mercury determining the amount of smelting nickel substrate Fire. Determination of the range in Table 1.
Table 1 Measuring range
Element measurement range /%
Lead 0.0001 to 0.010
Arsenic 0.0001 to 0.010
Cadmium 0.0001 to 0.010
Mercury 0.0001 to 0.010
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
Laboratory use specifications and test methods GB/T 6682 Analysis
GB/T 20066 Steel and iron - Sampling and determination of the chemical composition of the sample with a sample preparation method
3 Method summary
The sample is dissolved in hydrochloric acid and nitric acid, inductively coupled plasma mass spectrometer measured directly calculate the impurity elements by working curve method quality
The amount of concentration, mass fraction shows the measurement results.
4 Reagents
Unless otherwise stated, test water should comply with a water GB/T 6682 regulations.
4.1 hydrochloride (MOS level).
Nitrate 4.2 (MOS level).
4.3 nitric acid (15). with dilute nitric acid (4.2).
4.4 nitric acid (298). diluted nitric acid (4.2).
4.5 cesium, thallium, lead, arsenic, cadmium, mercury standard stock solution. a commercially available standard solution certified, mass concentration was 1000μg/mL.
4.6 Standard Solution A. Pipette respectively lead, arsenic, cadmium, mercury standard stock solution (4.5) to each 10.00mL 1000mL volumetric flask
50mL of nitric acid (4.2), dilute to the mark and mix. This solution 1mL lead, arsenic, cadmium, mercury each 10μg.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 953.11-2014_English be delivered?Answer: Upon your order, we will start to translate YS/T 953.11-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 953.11-2014_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 953.11-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|