HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YS/T 745.3-2010 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 745.3-2010: Methods for chemical analysis of copper anode slime. Part 3: Determination of platinum content and palladium comtent. Fire assay collection-inductively coupled coupled plasma atomic emission spectrometric methods
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 745.3-2010English209 Add to Cart 3 days [Need to translate] Methods for chemical analysis of copper anode slime. Part 3: Determination of platinum content and palladium comtent. Fire assay collection-inductively coupled coupled plasma atomic emission spectrometric methods   YS/T 745.3-2010

PDF similar to YS/T 745.3-2010


Standard similar to YS/T 745.3-2010

GB/T 4698.17   XB/T 619   YS/T 555.11   YS/T 745.11   YS/T 745.10   YS/T 745.2   

Basic data

Standard ID YS/T 745.3-2010 (YS/T745.3-2010)
Description (Translated English) Methods for chemical analysis of copper anode slime. Part 3: Determination of platinum content and palladium comtent. Fire assay collection-inductively coupled coupled plasma atomic emission spectrometric methods
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H14
Classification of International Standard 77.120.01
Word Count Estimation 6,696
Date of Issue 2010-11-22
Date of Implementation 2011-03-01
Regulation (derived from) MIIT (2010) No. 126
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the copper anode mud determination of platinum and palladium method. This standard applies to copper anode mud platinum and palladium content. Measuring range Pt 5. 00 g/t ~ 100. 00 g/t, palladium 10. 00g/t ~ 150. 00 g/t.

YS/T 745.3-2010: Methods for chemical analysis of copper anode slime. Part 3: Determination of platinum content and palladium comtent. Fire assay collection-inductively coupled coupled plasma atomic emission spectrometric methods



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of copper anode slime.Part 3. Determination of platinum content and palladium comtent.Fire assay collection-inductively coupled coupled plasma atomic emission spectrometric methods ICS 77.120.01 H14 People's Republic of China Nonferrous Metals Industry Standard Methods for chemical analysis of copper anode slime Part 3. The amount of platinum and palladium determining the amount of Fire Assaying enrichment - Inductively Coupled Plasma Emission Spectrometry Part 3. Determinationofplatinumcontentandpaladiumcontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 745 "Methods for chemical analysis of copper anode mud" is divided into nine sections. --- Part 1. Determination of copper content iodometry; --- Part 2. gold and silver content determination fire assay gravimetric method; --- Part 3. the amount of platinum and palladium contents - fire assay enrichment - Inductively coupled plasma atomic emission spectrometry; --- Part 4. Determination of the amount of selenium iodometry; --- Part 5. Determination of tellurium content dichromate method; --- Part 6. Determination of lead content Na2EDTA titration; --- Part 7. Determination of bismuth content - Flame atomic absorption spectrometric method and Na2EDTA titration; --- Part 8. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry; --- Part 9. Determination of antimony content - Flame atomic absorption spectrometry. This is Part 3. This section is in accordance with GB/T 1.1-2009 given rules drafted. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Daye Nonferrous Metals Corporation. This section is drafted. Beijing General Research Institute of Mining and Metallurgy. Participated in the drafting of this section. Daye Nonferrous Metals Corporation, Tongling Nonferrous Metals Group Holdings Co., Jiangxi Copper shares have Ltd., Jinchuan Group Limited, Northern Copper Co., Ltd., Guangzhou Nonferrous Metal Research Institute, Hunan Nonferrous Metals Research Institute. The main drafters of this section. Wanghao Ying, Chen Geng Temple, Yuan Yuxia, Ho Mei, Yu Xuebing, Yuangong Qi, Li Yanan, Gao Hong Bo, Wang Tinglong, Yang Hongsheng, Lvqing Cheng, Liu with silver, often Ji Xiang, Ma Lijun, Daifeng Ying, Lin Shan, Pangwen Lin, Huang Ping. Methods for chemical analysis of copper anode slime Part 3. The amount of platinum and palladium determining the amount of Fire Assaying enrichment - Inductively Coupled Plasma Emission Spectrometry

1 Scope

YS/T 745 This section specifies the determination of copper anode slime platinum and palladium content. This section applies to the determination of platinum, palladium, copper anode mud content. Measuring range Pt 5.00g/t ~ 100.00g/t; palladium 10.00g/t ~ 150.00g/t.

2 Method summary

Sample by fire assay enrichment, the formation of co-grain containing platinum palladium. After co-grain mixed acid dissolution, by inductively coupled plasma atomic emission spectrometry Instrument Determination solution of platinum and palladium.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 anhydrous sodium carbonate, commercially pure. 3.2 Lead oxide, palladium-platinum-free, commercially pure. 3.3 silica, commercially pure. 3.4 borax, commercially pure. 3.5 sodium chloride, commercially pure. 3.6 starch. 3.7 nitric acid (17), no chlorine ions. 3.8 glacial acetic acid (13). 3.9 mixed acid. hydrochloric acid, nitric acid (31), (now with the current). 3.10 platinum standard stock solution. Weigh 0.1000g platinum (≥99.9%) in 100mL beaker, add 20mL mixed acid (3.9), plus After dissolving heat, add 5 drops of sodium chloride solution 200g L /, on the steam bath to nearly dry, add 20mL hydrochloric acid dissolved and transferred to 100mL volumetric flask The diluted with water to volume, and mix. 1mL solution containing 1mg platinum. 3.11 palladium standard stock solution. Weigh 0.1000g of palladium (≥99.9%) in 100mL beaker 20mL mixed acid (3.9), heating After dissolution, add 5 drops of sodium chloride solution 200g L /, on the steam bath to nearly dry, add 20mL dissolved in hydrochloric acid and transferred to 100mL volumetric flask The diluted with water to volume, and mix. 1mL solution containing 1mg palladium. 3.12 platinum, palladium mixed standard solution. platinum were taken above the standard stock solution (3.10), palladium standard stock solution (3.11) each 10.00mL In 100mL flask, add 10mL mixed acid (3.9), diluted with water to volume, and mix. This solution 1mL containing 100μg platinum, 100μg palladium.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 745.3-2010_English be delivered?

Answer: Upon your order, we will start to translate YS/T 745.3-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 745.3-2010_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 745.3-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.