US$169.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 555.7-2009: Methods for chemical analysis of molybdenum concentrate. Determination of calcium oxide content. Flame atomic absorption spectrometry Status: Valid YS/T 555.7: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 555.7-2009 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of molybdenum concentrate. Determination of calcium oxide content. Flame atomic absorption spectrometry
| Valid |
YS/T 555.7-2009
|
| YS/T 555.7-2006 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Molybdenum concentrates. Determination of calcium content
| Obsolete |
YS/T 555.7-2006
|
PDF similar to YS/T 555.7-2009
Basic data | Standard ID | YS/T 555.7-2009 (YS/T555.7-2009) | | Description (Translated English) | Methods for chemical analysis of molybdenum concentrate. Determination of calcium oxide content. Flame atomic absorption spectrometry | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H14;D43 | | Classification of International Standard | 77.120.99 | | Word Count Estimation | 6,654 | | Date of Issue | 2009-12-04 | | Date of Implementation | 2010-06-01 | | Older Standard (superseded by this standard) | YS/T 555.7-2006 | | Regulation (derived from) | MIIT [2009] No. 66 | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This standard specifies the molybdenum content of calcium oxide method. This standard applies to molybdenum calcium oxide content. Measuring range: 0. 08 % 4. 80%. |
YS/T 555.7-2009: Methods for chemical analysis of molybdenum concentrate. Determination of calcium oxide content. Flame atomic absorption spectrometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of molybdenum concentrate.Determination of calcium oxide content.Flame atomic absorption spectrometry
ICS 77.120.99
H14
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 555.7-2006
Methods for chemical analysis of molybdenum concentrate
Calcium oxide content by flame atomic absorption spectrometry
Posted 2009-12-04
2010-06-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 555 "Methods for chemical analysis of molybdenum concentrate" includes 11 parts.
YS/T 555.1 Methods for chemical analysis of molybdenum concentrate molybdenum content of lead molybdate assay gravimetric method
YS/T 555.2 Methods for chemical analysis of molybdenum concentrate - Determination of silicon dioxide content and weight of molybdenum blue spectrophotometric method
YS/T 555.3 Methods for chemical analysis of molybdenum concentrate arsenic content - Atomic Fluorescence Spectrometry and DDTC-Ag spectrophotometry
YS/T 555.4 Methods for chemical analysis of molybdenum concentrate tin content - Atomic Fluorescence Spectrometry
YS/T 555.5 Methods for chemical analysis of molybdenum concentrate phosphorus content of molybdenum blue spectrophotometric determination of phosphorus
YS/T 555.6 Methods for chemical analysis of molybdenum concentrate copper, lead, bismuth, zinc content - Flame Atomic Absorption Spectrometry
YS/T 555.7 Methods for chemical analysis of molybdenum concentrate calcium oxide content by flame atomic absorption spectrometry
YS/T 555.8 Methods for chemical analysis of molybdenum concentrate - Determination of tungsten content - Thiocyanate spectrophotometric method
YS/T 555.9 Methods for chemical analysis of molybdenum concentrate the amount of potassium and sodium contents - Flame Atomic Absorption Spectrometry
YS/T 555.10 Methods for chemical analysis of molybdenum concentrate rhenium contents - Thiocyanate spectrophotometric
Determination of YS/T 555.11 Methods for chemical analysis of molybdenum concentrate oil and moisture content of the total weight of the law
This is Part 7.
"The method concentrates - Determination of calcium content" in this section instead of YS/T 555.7-2006 (formerly GB/T 15079.7-1994).
This portion of YS/T 555.7-2006 compared to the main changes are as follows.
Determination of calcium --- revision for the determination of calcium oxide content;
--- Increasing the molybdenum substrate method to eliminate interference;
--- Increasing the precision of the terms;
--- Text format has been modified, supplemented with quality assurance and control provisions.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This section is responsible for drafting unit. Jinduicheng Molybdenum Group Co., Ltd., China Nonferrous Metals Industry Institute of Standards and Metrology and Quality.
Participated in the drafting of this section. Luoyang Luanchuan Molybdenum Group Co., Jiangxi Copper Company (Dexing) mine development of new technologies limited
the company.
The main drafters of this section. Road Qingxiang, Zhao Yu, Wang Guoliang, Zhangjiang Feng, Cheng Jingfeng.
This part certifier. Tian Yonghong, strong beam Bin, Li Hongjun.
This part of the standard replaces the previous editions are.
--- GB/T 15079.7-1994;
--- YS/T 555.7-2006.
Methods for chemical analysis of molybdenum concentrate
Calcium oxide content by flame atomic absorption spectrometry
1 Scope
This section provides the determination of calcium oxide content of molybdenum concentrate.
This section applies to the determination of calcium oxide content of molybdenum concentrate. Measuring range. 0.08% - 4.80%.
2 Method summary
Sample prior to 500 ℃ muffle furnace burning to remove large amounts of sulfur, carbon, oil, and then acid decomposition. Hydrochloric acid in a suitable medium, strontium salt
And lanthanum salts as release agents, atomic absorption spectrometer at a wavelength of 422.7nm, air - acetylene flame measured absorbance of calcium oxide.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
3.1 nitrate (ρ1.42g/mL), pure class distinctions.
3.2 hydrochloric acid (ρ1.19g/mL), pure class distinctions.
3.3 Hydrofluoric acid (ρ1.13g/mL).
3.4 perchloric acid (ρ1.68g/mL), pure class distinctions.
3.5 HCl (1 + 1).
3.6 strontium chloride and lanthanum chloride mixed solution. Weigh 10g pure spectrum of strontium chloride (SrCl2 · 6H2O) and lanthanum chloride 20g pure spectrum, placed
400mL beaker, add a small amount of water, dissolved by heating, cooling, transferred to 200mL volumetric flask, dilute with water to volume, and mix.
3.7 calcium oxide standard solution. Weigh 0.1785g advance at 105 ℃ drying 1h and was cooled to room temperature inside the dryer calcium carbonate (base
Quasi reagent), placed in 300mL beaker, covered with a watch glass, was added 10mL of hydrochloric acid (3.5) low-temperature heating to dissolve completely cooled and transferred to 1000mL
Volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100μg calcium oxide. Store in plastic bottle.
3.8 molybdenum substrate solution (5mg/mL). Weigh 0.7500g of high purity molybdenum trioxide reagent in 200mL beaker, add 30mL water and
1mL ammonia (ρ0.90g/mL, superior grade pure), after dissolved by heating, boiling 5min, cooled and transferred to 100mL volumetric flask, dilute to the mark with water
Degree, and mix.
4 Instrument
Atomic absorption spectrometer, with a calcium hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Precision minimum requirements. measuring the absorbance of the highest standard solution 10 times the standard deviation should not exceed the average absorbance
1.0%. Lowest measured standard solution (not a "zero" standard solution) absorbance of 10 times the standard deviation should not exceed the maximum standard
0.5% average standard solution absorbance.
--- Characteristic concentration. the test solution and measurement matrix consistent solution, characterized in calcium concentration should not exceed 0.08μg/mL.
--- Linear standard curve. The standard curve is divided into five sections according to concentration, than the difference between the absorbance of the absorbance difference between the highest and the lowest segment segment
Not less than 0.7.
5 Sample
Specimens shall be pre-stripped oil and moisture, particle size less than 0.090mm. After the sample should be 100 ℃ ~ 105 ℃ baking 1h, dry place
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 555.7-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 555.7-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 555.7-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 555.7-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 555.7-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 555.7-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|