YS/T 53.3-2010 English PDF

US$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 53.3-2010: Methods for chemical analysis of copper, lead, zinc original and tailing ores. Part 3: Determination of silver content. Flame atomic absorption spectrometric
Status: Valid

YS/T 53.3: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 53.3-2010English159 Add to Cart 3 days [Need to translate] Methods for chemical analysis of copper, lead, zinc original and tailing ores. Part 3: Determination of silver content. Flame atomic absorption spectrometric Valid YS/T 53.3-2010
YS/T 53.3-1992English199 Add to Cart 2 days [Need to translate] (Copper, lead and zinc ore and tailings chemical analysis. Flame Atomic Absorption Spectrometry silver content) Obsolete YS/T 53.3-1992

PDF similar to YS/T 53.3-2010


Standard similar to YS/T 53.3-2010

GB/T 4698.17   XB/T 619   YS/T 555.11   YS/T 568.13   YS/T 254.8   YS/T 53.1   

Basic data

Standard ID YS/T 53.3-2010 (YS/T53.3-2010)
Description (Translated English) Methods for chemical analysis of copper, lead, zinc original and tailing ores. Part 3: Determination of silver content. Flame atomic absorption spectrometric
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H14
Classification of International Standard 77.120.01
Word Count Estimation 6,649
Date of Issue 2010-11-22
Date of Implementation 2011-03-01
Older Standard (superseded by this standard) YS/T 53.3-1992
Regulation (derived from) MIIT (2010) No. 126
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the copper, lead, zinc and silver ore and tailings in the determination method. This standard applies to copper, lead, zinc ore and tailings in silver content. This part measurement range: 0. 50g/t ~ 200g/t.

YS/T 53.3-2010: Methods for chemical analysis of copper, lead, zinc original and tailing ores. Part 3: Determination of silver content. Flame atomic absorption spectrometric


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of copper, lead, zinc original and tailing ores.Part 3. Determination of silver content.Flame atomic absorption spectrometric ICS 77.120.01 H14 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 53.3-1992 Copper, lead, zinc ore tailings and chemical analysis methods Part 3. Determination of silver content Flame Atomic Absorption Spectrometry Methodsforchemicalanalysisofcopper, lead, zincoriginalandtailingores- Part 3. Determinationofsilvercontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 53 "Copper, lead, zinc ore tailings and chemical analysis method" is divided into three parts. --- Part 1. Determination of the amount of gold fire assay enrichment - flame atomic absorption spectrometry; --- Part 2. determination of gold by Flow Injection Micro - column separation -8531 fiber enrichment - flame atomic absorption spectrometry; --- Part 3. Determination of the amount of silver by flame atomic absorption spectrometry. This section is part 3. This section is in accordance with GB/T 1.1-2009 given rules drafted. This part is YS/T 53.3-1992 amendments. This section compared with YS/T 53.3-1992, have the following main changes. --- Increased the preamble; --- Omitted "reference standard" one; --- Text format has been modified; --- Increasing the precision part; --- Increased quality assurance and control provisions. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is drafted. Beijing Mining Research Institute, Guangzhou Nonferrous Metal Research Institute. Participated in the drafting of this section. Lingnan Shaoguan smelter Ltd., Chinalco Luoyang Copper Co., Ltd., Henan Yuguang Gold & Lead Group Co., Ltd., Tongling Nonferrous Metals Group Holdings Limited, Shuikoushan Nonferrous Metals Group Co., Ltd. The main drafters of this section. Chao Chen Yan, Chen Geng Temple, Wanghao Ying, Yuan Yuxia Zhao Xi South Daifeng Ying, Lin Shan, Lin Ye, high Yu, Kong Jianmin, Fan Zhanfang, Tanping Sheng, Li Ailing. This part of the standard replaces the previous editions are. --- YS/T 53.3-1992. Copper, lead, zinc ore tailings and chemical analysis methods Part 3. Determination of silver content Flame Atomic Absorption Spectrometry

1 Scope

YS/T of the provisions of section 53 of the method for the determination of copper, lead, zinc ore and tailings in silver content. This section applies to the determination of copper, lead, zinc ore and tailings in silver content. This section measurement range. 0.50g/t ~ 200g/t.

2 Method summary

Sample was dissolved with hydrochloric acid, nitric acid, hydrofluoric acid and perchloric acid. Air - acetylene flame atomic absorption spectrometer wavelength 328.1nm At measuring the absorbance of silver. Silver content is calculated using the working curve method.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 hydrochloric acid. 3.2 nitrate. 3.3 perchloric acid. 3.4 hydrofluoric acid. 3.5 butyl acetate. 3.6 diphenylthiourea - butyl acetate (2g/L). 1g 500mL diphenyl thiourea were dissolved butyl acetate (3.5) in. 3.7 Silver standard stock solution. Weigh 0.5000g of metallic silver (≥99.99%), placed in a beaker of 200mL, 25mL of nitric acid was added (3.2), cover the surface of the pan, boil until completely dissolved and get rid of nitrogen oxides, removed, washed with water and dish table Beibi, cooled to room temperature. Moved 500mL brown volumetric flask, dilute with water to volume, and mix. 1mL solution containing 1mg silver. 3.8 silver standard solution A. Pipette 10.00mL silver standard stock solution (3.7) into 1000mL brown volumetric flask, add salt 100mL Acid (3.1), dilute to the mark and mix. This solution 1mL containing 10μg silver. 3.9 silver standard solution B. Pipette 25.00mL silver standard solution A (3.8) previously placed there 25mL hydrochloric acid (3.1) of 250mL brown Color volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 1μg silver.

4 Instrument

Atomic absorption spectrometer (with a background subtraction function), with a silver hollow-cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Sensitivity. the substrate solution consistent with the measurement solution, features silver concentration should be less than 0.030μg/mL; --- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%; The lowest concentration of standard solution used (instead of "zero" standard solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum concentration 0.5% of the mean absorbance of the standard solution;

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 53.3-2010_English be delivered?

Answer: Upon your order, we will start to translate YS/T 53.3-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 53.3-2010_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 53.3-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YS/T 53.3-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 53.3-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.