HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YS/T 520.4-2007 English PDF

US$199.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 520.4-2007: Chemical analysis of gallium. Part 4: Determination of iron content. The 4, 7-diphenyl-1, 10-phenanthroline spectrophotometric method
Status: Valid

YS/T 520.4: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 520.4-2007English199 Add to Cart 3 days [Need to translate] Chemical analysis of gallium. Part 4: Determination of iron content. The 4, 7-diphenyl-1, 10-phenanthroline spectrophotometric method Valid YS/T 520.4-2007
YS/T 520.4-2006English199 Add to Cart 2 days [Need to translate] Methods for chemical analysis of gallium. The 4, 7-diphenyl-1, 10-phenanthroline photometric method for the determination of iron content Obsolete YS/T 520.4-2006

PDF similar to YS/T 520.4-2007


Standard similar to YS/T 520.4-2007

GB/T 4698.17   XB/T 619   YS/T 555.11   YS/T 540.2   YS/T 540.3   YS/T 540.1   

Basic data

Standard ID YS/T 520.4-2007 (YS/T520.4-2007)
Description (Translated English) Chemical analysis of gallium. Part 4: Determination of iron content. The 4, 7-diphenyl-1, 10-phenanthroline spectrophotometric method
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H14
Classification of International Standard 77.120.70
Word Count Estimation 6,628
Date of Issue 2007-11-14
Date of Implementation 2008-05-01
Older Standard (superseded by this standard) YS/T 520.4-2006
Regulation (derived from) NDRC Notice No. 77 of 2007
Issuing agency(ies) National Development and Reform Commission
Summary This standard specifies the gallium Determination of iron content. This standard applies to the determination of the iron content of gallium. Measuring range: 0. 00005% to 0. 015%

YS/T 520.4-2007: Chemical analysis of gallium. Part 4: Determination of iron content. The 4, 7-diphenyl-1, 10-phenanthroline spectrophotometric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis of gallium.Part 4. Determination of iron content.The 4, 7-diphenyl-1, 10-phenanthroline spectrophotometric method ICS 77.120.70 H14 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 520.4-2006 Chemical analysis of gallium Part 4. Determination of iron content 4,7-diphenyl-1,10-phenanthroline spectrophotometry Posted 2007-11-14 2008-05-01 implementation National Development and Reform Commission issued

Foreword

YS/T 520-2007 "Chemical analysis of gallium" Is the YS/T 520-2006 (formerly GB/T 4375-1984) amendments, divided into Part 12. --- Part 1. Determination of copper content of 2,9-dimethyl-4,7-diphenyl-1,10-phenanthroline spectrophotometry --- Part 2. Determination of lead content of 4- (2-pyridyl) - resorcinol spectrophotometry --- Part 3. Determination of aluminum content Chromazurol S- tetradecyl pyridine bromide spectrophotometric method --- Part 4. Determination of iron content of 4,7-diphenyl-1,10-phenanthroline spectrophotometry --- Part 5. Determination of calcium content nitrous oxide - acetylene flame atomic absorption spectrometry --- Part 6. Determination of tin content salicylfluorone - cetyl trimethyl ammonium bromide, spectrophotometry --- Part 7. Determination of silicon content extraction - molybdenum blue spectrophotometric method --- Part 8. Determination of indium content of ethyl violet spectrophotometry --- Part 9. Determination of germanium content Phenylfluorone - polyethylene glycol octyl phenyl ether extraction spectrophotometric method --- Part 10. Determination of zinc content atomic absorption spectrometry --- Part 11. Determination of mercury content of the cold atomic absorption spectrometry --- Part 12. lead, copper, nickel, aluminum, indium and zinc Determination of chemical spectroscopy This is Part 4. The partial replacement of YS/T 520.4-2006 (formerly GB/T 4375.4-1984). This part is YS/T 520.4-2006 "Chemical analysis of gallium - Part 4. Determination of iron content of 4,7-diphenyl-1,10 Phenanthroline spectrophotometry "editorial finishing. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This standard by the Aluminum Corporation of China Shandong branch responsible for drafting. Drafters of this section. Yun-Xia Wang, Liu Yulong, Tian Rui, Qi Yanli. The non-ferrous metal part by the National Standardization Technical Committee responsible for the interpretation. This part of the standard replaces the previous editions are. --- YS/T 520.4-2006 (formerly GB/T 4375.4-1984). Chemical analysis of gallium Part 4. Determination of iron content 4,7-diphenyl-1,10-phenanthroline spectrophotometry

1 Scope

This section provides the determination of gallium in iron content. This section applies to the determination of iron content in gallium. Measurement range. 0.00005% to 0.015%.

2 Method summary

The sample is dissolved in hydrochloric acid and nitric acid. With hydroxylamine hydrochloride reduced iron (Ⅲ), sodium citrate masked substrate gallium, at pH = 5 ~ 6 iron conditions (Ⅱ) with 4,7-diphenyl-1,10-phenanthroline to form a red complex was extracted with iso-amyl alcohol, measured at 530nm wavelength spectrophotometer Absorbance.

3 Reagents

3.1 ethanol, pure class distinctions. 3.2 isoamyl alcohol. 3.3 ammonia, pure class distinctions. 3.4 nitric acid, 120 ℃ purified by distillation. 3.5 hydrochloric acid, sodium boiling purified by distillation. 3.6 4,7-diphenyl-1,10-phenanthroline ethanol solution (2g/L). 3.7 hydroxylamine hydrochloride solution (200g/L). Weigh 100g of hydroxylamine hydrochloride, 25g of anhydrous sodium acetate, into 800mL beaker, dissolved in water Diluted to 500mL, placed and heated to 80 ℃ ~ 90 ℃ water bath, added 10mL4,7--diphenyl-1,10-phenanthroline solution (3.6) and 10mL absolute ethanol (3.1), stir with a glass rod in the water bath for 20min, removed, placed more than 4h. The solution was transferred to 1000mL separating funnel, add 30mL isoamyl alcohol (3.2), severe shock, standing layered organic phase was discarded. Repeat this procedure until The organic phase was colorless. The aqueous phase was transferred to a polyethylene bottle save. 3.8 sodium citrate solution (300g/L). Weigh 150g sodium citrate, 2g of hydroxylamine hydrochloride, placed in 800mL beaker, dissolved in water diluted Diluted to 500mL, according to the following hydroxylamine hydrochloride solution (3.7) the heat from the water bath to 80 ℃ ~ 90 ℃ start. If the iron content Too high, there should be another purification operation. 3.9 thiourea solution (100g/L). Weigh 10g of thiourea in 250mL beaker, dissolved in water and diluted to 100mL, hydroxylamine hydrochloride according to the following Amine solution (3.7) said, from the water bath was heated to 80 ℃ ~ 90 ℃ start [4,7-diphenyl-1,10-phenanthroline solution (3.6) and Iso-amyl alcohol (3.2) used were changed to 5mL and 15mL]. 3.10 iron standard stock solution. Weigh 1.0000g iron [(Fe) ≥99.99%], placed in 400mL beaker, add 30mL nitrate Acid (1 + 1), and dissolved by heating to remove nitrogen oxides, cooled and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. this Solution 1mL containing 1.0mg iron. 3.11 Iron standard solution. Pipette 10.00mL iron standard stock solution (3.10), placed in 100mL volumetric flask, dilute to the mark, Mix well. This solution 1mL containing 100μg iron. 3.12 Iron standard solution. Pipette 10.00mL iron standard solution (3.11), placed in 100mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 10μg iron. 3.13 Iron standard solution. Pipette 10.00mL iron standard solution (3.12), placed in 100mL volumetric flask, dilute with water to volume, and mix.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 520.4-2007_English be delivered?

Answer: Upon your order, we will start to translate YS/T 520.4-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 520.4-2007_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 520.4-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YS/T 520.4-2007?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 520.4-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.