US$259.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 4501.3-2017: Chemical analysis of nickel concentrate. Part 3: Determination of gold,platinum,palladium. Inductively coupled plasma mass spectrometry method Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
SN/T 4501.3-2017 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
Chemical analysis of nickel concentrate. Part 3: Determination of gold,platinum,palladium. Inductively coupled plasma mass spectrometry method
| Valid |
SN/T 4501.3-2017
|
PDF similar to SN/T 4501.3-2017
Basic data Standard ID | SN/T 4501.3-2017 (SN/T4501.3-2017) | Description (Translated English) | Chemical analysis of nickel concentrate. Part 3: Determination of gold��platinum��palladium. Inductively coupled plasma mass spectrometry method | Sector / Industry | Commodity Inspection Standard (Recommended) | Classification of Chinese Standard | H13 | Word Count Estimation | 11,170 | Date of Issue | 2017-05-12 | Date of Implementation | 2017-12-01 | Quoted Standard | GB/T 6379.2; GB/T 6682; GB/T 25952 | Regulation (derived from) | State-Quality-Inspection-Accreditation (2017) 228 | Issuing agency(ies) | General Administration of Customs | Summary | This standard specifies the inductively coupled plasma mass spectrometry method for the determination of gold, platinum and palladium in nickel concentrate. This section applies to the determination of gold, platinum and palladium in nickel concentrate. The measurement range is: Au 0.01 g / t ~ 5g / t; Pt 0.01g / t ~ 10g / t; Pd 0.01g / t ~ 10g / t. |
SN/T 4501.3-2017: Chemical analysis of nickel concentrate. Part 3: Determination of gold,platinum,palladium. Inductively coupled plasma mass spectrometry method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis of nickel concentrate. Part 3. Determination of gold,platinum,palladium.Inductively coupled plasma mass spectrometry method
People's Republic of China entry and exit inspection and quarantine industry standards
Nickel concentrate chemical analysis method
Part 3. Determination of gold, platinum and palladium content
Inductively coupled plasma mass spectrometry
Part 3.Determinationofgold,platinum,paladium-
Released on.2017-05-12
2017-12-01 implementation
People's Republic
The General Administration of Quality Supervision, Inspection and Quarantine issued
Foreword
SN/T 4501 "Chemical Analysis Method for Nickel Concentrate" is divided into three parts.
---Part 1. Determination of the content of nickel, cobalt, copper, manganese, magnesium and calcium - Inductively coupled plasma atomic emission spectrometry;
--- Part 2. Determination of gallium, antimony, selenium, cadmium, indium, antimony, antimony and bismuth content by inductively coupled plasma mass spectrometry;
---Part 3. Determination of gold, platinum and palladium content by inductively coupled plasma mass spectrometry.
This part is the third part of the SN/T 4501.
This part is drafted in accordance with the provisions given in GB/T 1.1-2009.
This part is proposed and managed by the National Certification and Accreditation Administration.
This section is mainly drafted by. Gansu Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Jinchuan Group Co., Ltd.
The main drafters of this section. Yan Na, Wang Junfeng, Zu Aiguo, Zhao Shenguo, Zheng Hongwen, Shi Jinmin, He Yan.
Nickel concentrate chemical analysis method
Part 3. Determination of gold, platinum and palladium content
Inductively coupled plasma mass spectrometry
1 Scope
This part of SN/T 4501 specifies inductively coupled plasma mass spectrometry for the determination of gold, platinum and palladium in nickel concentrates.
This section is applicable to the determination of gold, platinum and palladium in nickel concentrate. The measurement range is. Au0.01g/t~5g/t; Pt0.01g/t~
10g/t; Pd 0.01g/t ~ 10g/t.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 6379.2 Accuracy of measurement methods and results (accuracy and precision) Part 2. Determination of standard method of measurement
Basic method of sex and reproducibility
GB/T 6682 Analytical laboratory water specifications and test methods (GB/T 6682-2008, ISO 3696.1987, MOD)
GB/T 25952 Bulk flotation nickel concentrate sampling and sample preparation method
3 Principle
The sample and the mixed flux are mixed in proportion, and melted at a high temperature to obtain a precious metal granule, which is sequentially dissolved by dissolving precious metal with nitric acid and aqua regia.
A solution of gold, platinum, or palladium. Determination of the signal value of an element in the above solution by inductively coupled plasma mass spectrometry (ICP-MS) using an internal standard
Method of quantification. The concentration of the element in the solution is proportional to the signal value of the instrument within the measurement range of the element.
4 reagents and materials
Unless otherwise stated, the reagents used were of analytical grade and the water was secondary water specified in GB/T 6682.
4.1 Sodium carbonate powder.
4.2 Borax powder.
4.3 Lead oxide powder (containing gold < 0.25μg/kg; platinum < 0.25μg/kg; palladium < 0.25μg/kg).
4.4 Silica powder.
4.5 Potassium nitrate powder.
4.6 Starch powder.
4.7 Silver powder ≥99.99%.
4.8 Nitric acid (ρ=1.42g/mL), excellent grade.
4.9 Hydrochloric acid (ρ=1.19g/mL), excellent grade.
4.10 Acetic acid (ρ = 1.05 g/mL).
4.11 Single element standard stock solution (1000mg/L). Standard solutions for gold, platinum and palladium use certified reference materials.
|