HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

SN/T 3249.2-2012 English PDF

US$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 3249.2-2012: Imitation jewelry and accessory. Part 2: Determination of lead, cadmium, barium, antimony and mercury. Inductively coupled plasma optic emission spectrometry method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 3249.2-2012English259 Add to Cart 3 days [Need to translate] Imitation jewelry and accessory. Part 2: Determination of lead, cadmium, barium, antimony and mercury. Inductively coupled plasma optic emission spectrometry method Valid SN/T 3249.2-2012

PDF similar to SN/T 3249.2-2012


Standard similar to SN/T 3249.2-2012

GB 19593   GB/T 18043   GB 11887   SN/T 3249.4   SN/T 3249   SN/T 3249.3   

Basic data

Standard ID SN/T 3249.2-2012 (SN/T3249.2-2012)
Description (Translated English) Imitation jewelry and accessory. Part 2: Determination of lead, cadmium, barium, antimony and mercury. Inductively coupled plasma optic emission spectrometry method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard Y88
Word Count Estimation 10,147
Quoted Standard GB/T 6682; GB/T 22788-2008; SN/T 2046-2008
Regulation (derived from) National Quality Inspection (2012) 777; industry standard filing Notice 2013 No. 4 (No. 160 overall)
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the imitation jewelry alloys, coatings, textiles, leather, polymers and other similar materials of lead (Pb), cadmium (Cd), barium (Ba), antimony (Sb), mercury (Hg) Content of the inductor coupled plasma atomic emission spectrometr

SN/T 3249.2-2012: Imitation jewelry and accessory. Part 2: Determination of lead, cadmium, barium, antimony and mercury. Inductively coupled plasma optic emission spectrometry method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Imitation jewelry and accessory.Part 2. Determination of lead, cadmium, barium, antimony and mercury.Inductively coupled plasma optic emission spectrometry method People's Republic of China Entry-Exit Inspection and Quarantine Standards Simulation accessories Part 2. lead, cadmium, barium, Determination of antimony, mercury content Inductively coupled plasma atomic emission spectrometry Imitationjewelryandaccessory-Part 2. Determinationoflead, cadmium, barium, antimonyandmercury- Issued on. 2012-12-12 2013-07-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

SN/T 3249 "simulation jewelry" is divided into three parts. --- Part 1. lead, cadmium, barium content - Flame atomic absorption spectrometry; --- Part 2. Determination of the inductance of lead, cadmium, barium, antimony, mercury content coupled plasma atomic emission spectrometry; --- Part 3. antimony, mercury content by atomic fluorescence spectrometry. This section SN/T Section 23249 of. This section drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section was drafted by. People's Republic of China Shandong Entry Inspection and Quarantine Bureau, People's Republic of China Guangdong Entry-Exit Inspection and Quarantine Bureau, Chinese Academy of Inspection and Quarantine, People's Republic of China Zhejiang Exit Inspection and Quarantine, People's Republic of China Shanghai Entry-Exit Inspection Inspection and quarantine bureau. The main drafters of this section. Wang Jinhua, Xing force, Xu Ying, Liuchong Hua, Zhang, Chen Yin Cong, Yangrong Jing. Simulation accessories Part 2. lead, cadmium, barium, Determination of antimony, mercury content Inductively coupled plasma atomic emission spectrometry

1 Scope

SN/T 3249 provisions of this part of the simulation jewelry alloys, coatings, textiles, leather, polymers and other similar materials Lead (Pb), cadmium (Cd), barium (Ba), antimony (Sb), mercury (Hg) content by inductively coupled plasma atomic emission spectrometry (ICP-OES) measurement method. This section applies to imitation jewelry alloys, coatings, textiles, leather, polymers and other similar materials of lead (Pb), cadmium (Cd), barium (Ba), antimony (Sb), determination of mercury (Hg) content of lead (Pb), antimony (Sb), mercury (Hg) lower limit of quantification of 15mg/kg, cadmium (Cd), barium (Ba) The lower limit of quantification of 10mg/kg.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Laboratory use - Specification and test methods GB/T 6682 Analysis Determination of GB/T 22788-2008 toy surface coatings of the total lead content SN/T 2046-2008 Plastics and articles thereof measured inductance of lead, mercury, chromium, cadmium, barium, arsenic coupled plasma atomic emission light Spectroscopy

3 Method summary

After the sample concentrated acid complete digestion using ICP-OES analysis measured at a wavelength corresponding solution of lead, cadmium, barium, antimony, mercury elements content.

4 Reagents

Unless otherwise specified, use only pure reagents superior grade and in line with two water GB/T 6682 regulations or equivalent purity. 4.1 pure zinc. purity of not less than 99.99%, lead, cadmium, barium, antimony, mercury content of less than 0.0005%. 4.2 iron. purity of not less than 99.99%, lead, cadmium, barium, antimony, mercury content of less than 0.0005%. 4.3 copper. purity of not less than 99.99%, lead, cadmium, barium, antimony, mercury content of less than 0.0005%. 4.4 Concentrated nitric acid (ρ = 1.42g/mL, 65%). 4.5 Concentrated hydrochloric acid (ρ = 1.19g/mL, 37%). 4.6 nitric acid solution (volume fraction, 1090). 4.7 nitric acid solution (volume fraction, 595). 4.8 Hydrogen peroxide (ρ = 1.10g/mL, 30%). 4.9 Lead (1000mg/L) single-element standard solution with traceable certificate. 4.10 Cadmium (1000mg/L) single-element standard solution with traceable certificate.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 3249.2-2012_English be delivered?

Answer: Upon your order, we will start to translate SN/T 3249.2-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 3249.2-2012_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 3249.2-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.