US$259.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 1504.4-2005: Plastics used for food container and package. Part 4: Determination of phenolic antioxidants in high density polyethylene. Liquid chromatography Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SN/T 1504.4-2005 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
Plastics used for food container and package. Part 4: Determination of phenolic antioxidants in high density polyethylene. Liquid chromatography
| Valid |
SN/T 1504.4-2005
|
PDF similar to SN/T 1504.4-2005
Basic data | Standard ID | SN/T 1504.4-2005 (SN/T1504.4-2005) | | Description (Translated English) | Plastics used for food container and package. Part 4: Determination of phenolic antioxidants in high density polyethylene. Liquid chromatography | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | A82 | | Classification of International Standard | 55.100 | | Word Count Estimation | 8,838 | | Date of Issue | 2005-02-17 | | Date of Implementation | 2005-07-01 | | Adopted Standard | ASTM D5524-1994, MOD | | Regulation (derived from) | Industry standard filing Notice 2005 No. 4 (No. 64 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China | | Summary | This standard specifies the import and export of food containers, packaging high-density polyethylene with a phenolic antioxidant content determination. This standard applies to food containers, packaging high-density polyethylene phenolic antioxidants separation and determination. |
SN/T 1504.4-2005: Plastics used for food container and package. Part 4: Determination of phenolic antioxidants in high density polyethylene. Liquid chromatography ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plastics used for food container and package.Part 4. Determination of phenolic antioxidants in high density polyethylene.Liquid chromatography
Book of the People's Republic of China Entry and Exit Inspection and Quarantine
Food containers, plastic materials for packaging - Part 4.
Determination of phenolic antioxidants in high density polyethylene
Liquid chromatography
Released on.2005-02-17
2005-07-01 implementation
People's Republic
The General Administration of Quality Supervision, Inspection and Quarantine issued
Foreword
SN/T 1504 "Food Containers, Plastic Materials for Packaging" is divided into five parts.
--- Part 1. Determination of phenolic antioxidants and erucamide slip agents in polypropylene homopolymers.
--- Part 2. Determination of phenolic antioxidants and succinic acid slip agents in linear low-density polyethylene - Liquid chromatography;
---Part 3. Determination of butyl-hydroxytoluene (BHT) in ethylene polymers and ethylene-vinyl acetate (EVA) copolymers
Phase chromatography
---Part 4. Determination of phenolic antioxidants in high-density polyethylene - Liquid chromatography;
---Part 5. Determination of content of impurity elements in polyolefins by X-ray fluorescence spectrometry.
This part is the fourth part of the SN/T 1504.
This section is modified to use the contents of ASTM D5524-1994, the title of which is changed to "high density of plastic containers for food containers and packaging."
Determination of phenolic antioxidants in polyethylene by liquid chromatography".
Appendix A of this section is an informative annex.
This part is proposed and managed by the National Certification and Accreditation Administration.
This part is drafted by the Tianjin Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China.
The main drafters of this section. Liu Shaocong, Liu Jun, Lu Gang, Zhang Lai, Ma Jun.
This section is the first industry standard for entry-exit inspection and quarantine.
Food containers, plastic materials for packaging - Part 4.
Determination of phenolic antioxidants in high density polyethylene
Liquid chromatography
1 Scope
This part of SN/T 1504 specifies the determination of phenolic antioxidants in high-density polyethylene for import and export food containers and packaging.
method.
This section applies to the separation and determination of phenolic antioxidants in food containers and high density polyethylene for packaging.
2 Method summary
The high density polyethylene sample was ground to 20 mesh and refluxed with cyclohexane. The extract was determined by liquid chromatograph internal standard method.
3 reagents and solutions
3.1 2(2'hydroxy-5'-methylphenyl)benzothiazole (Tinuvin-P).
3.2 Cyclohexane. liquid chromatography grade, spectrally pure or chromatographically pure reagent.
3.3 T-P internal standard solution. Tinuvin-P internal standard was added to the cyclohexane reagent to prepare a solution with a mass concentration of 51.8 mg/L.
3.4 Water. Degassing by high-purity helium or degassing by vacuum filtration.
3.5 Acetonitrile. liquid chromatography grade, spectrally pure or chromatographically pure reagent.
3.6 2-propanol. liquid chromatography grade, spectrally pure or chromatographically pure reagent.
WARNING. Cyclohexane and 2-propanol are flammable and the extraction process should be carried out in a fume hood.
4 instruments
4.1 Liquid Chromatograph. equipped with a UV detector, column heating system and gradient elution unit with a 10 μL sample injection valve.
4.2 Wiley Mill. A 20-mesh screen and water cooling system are installed to prevent thermal decomposition of the antioxidant.
4.3 Reflow extraction device. by condenser tube (20/40 glass grinding port), 125mL flat-bottomed flask (with 24/40 glass grinding port) and with magnetic force
Agitated heating plate consists of. The sample extraction device is shown in Figure A. 1.
4.4 Filtration unit. Teflon filter disc for non-aqueous solutions (pore size 0.22 μm) with a 5 mL syringe.
4.5 Analytical balance. accurate to ±0.0001g.
5 liquid chromatograph conditions
5.1 Detector. The UV detector wavelength is set at.200 nm and the absorbance measurement is set to 0.1A.
5.2 Column. Reversed phase C18, 5μm, 150mm × 4.6mm.
5.3 Gradient elution procedure.
a) Initial mobile phase conditions. acetonitrile-water (50+50).
b) Termination of mobile phase conditions. 100% acetonitrile.
c) Gradient length. 11 min, gradient curve. straight line, flow rate. 1.0 mL/min.
d) Maintain 100% acetonitrile for 8 min. The mobile phase was adjusted to 19.1 min to acetonitrile.water = 50.50 at a flow rate of 1.5 mL/min.
Hold for 5 min.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 1504.4-2005_English be delivered?Answer: Upon your order, we will start to translate SN/T 1504.4-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 1504.4-2005_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 1504.4-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|