US$209.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 1431.5-2011: Rules for the inspection of low-voltage electrical apparatus for import and export. Part 5: Low-voltage fuses Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SN/T 1431.5-2011 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Rules for the inspection of low-voltage electrical apparatus for import and export. Part 5: Low-voltage fuses
| Valid |
SN/T 1431.5-2011
|
PDF similar to SN/T 1431.5-2011
Basic data | Standard ID | SN/T 1431.5-2011 (SN/T1431.5-2011) | | Description (Translated English) | Rules for the inspection of low-voltage electrical apparatus for import and export. Part 5: Low-voltage fuses | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | K31 | | Classification of International Standard | 29.120.50 | | Word Count Estimation | 8,894 | | Date of Issue | 2011-09-30 | | Date of Implementation | 2012-04-01 | | Older Standard (superseded by this standard) | SN/T 1030-2001 | | Quoted Standard | GB/T 2828.1-2003; GB/T 2900.18-2008; GB 13539.1-2008; GB/T 13539.2-2008; GB 13539.3-2008; GB/T 13539.4-2009; SN/T 0002 | | Regulation (derived from) | National Quality Inspection (2011) 492; industry standard filing Notice 2012 No. 4 (No. 148 overall) | | Issuing agency(ies) | General Administration of Customs | | Summary | This standard specifies the import and export of low-voltage fuse sampling, testing and results of determination. This standard applies to the rated voltage not exceeding 1000V, or DC does not exceed 1500V, rated breaking capacity and is equipped with no less than 6kA closed low-voltage current-limiting fuses fuse inspection. This section does not apply to small fuse test. |
SN/T 1431.5-2011: Rules for the inspection of low-voltage electrical apparatus for import and export. Part 5: Low-voltage fuses ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules for the inspection of low-voltage electrical apparatus for import and export.Part 5. Low-voltage fuses
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Instead of the SN/T 1030-2001
Low-voltage electrical inspection of import and export
Part 5. Low voltage fuses
andexport-Part 5. Low-voltagefuses
Issued on. 2011-09-09
2012-04-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
SN/T 1431 "Importers and low-voltage electrical inspection procedures" series of standards is divided into five parts.
--- Part 1. General requirements
--- Part 2. Household and similar circuit breakers for overcurrent protection
--- Part 3. Household and similar residual current operated circuit breaker
--- Part 4. Electromechanical contactors and motor starters
--- Part 5. Low voltage fuses
This is Part 5 SN/T 1431 "Importers and low-voltage electrical inspection procedures" series of standards.
This section based on GB/T 1.1-2009 write drafted.
Some of this section may involve patents, this part of the release mechanism does not assume the responsibility to identify these patents.
The partial replacement of SN/T 1030-2001, compared with the SN/T 1030-2001 The main changes are as follows.
--- Examine the contents of the deleted original packaging procedures, shape and installation dimensions, plug inspection and testing of semiconductor devices;
--- Increasing the consistency test project, assembly quality inspection;
--- Modify the contents flag check, insulation test is amended as insulation and isolation suitability verification;
--- Table 2. visual inspection of the surface of the product failed to Category B, the fuse characteristics test failure unified classification A;
--- Increased content inspection and supervision mode and test mode.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
This section drafted by. People's Republic of China Zhejiang Exit Inspection and Quarantine.
The main drafters of this section. Yu Jinjun, Wang Jianxin, high Qiu He, Wang Junjie.
This part of the standard replaces the previous editions are.
--- SN/T 1030-2001.
Introduction
"Importers and low-voltage electrical inspection of" low-voltage electrical products import and export inspection work basis, import and export of low-voltage electrical products
Inspection play a guiding and regulating.
With China's accession to the World Trade Organization (WTO) and the revised "People's Republic of China Import and Export Commodity Inspection Law" Import and Export Commodity Inspection
Test mode has undergone great change, to adapt to changes in the situation and to meet the actual needs of inspection and quarantine work, Inspection and Quarantine of the competent
Inspection and quarantine departments to establish a standard system.
This part belongs to the standard system of inspection and quarantine fourth floor --- personality standard that specifies the requirements for the import and export inspection low voltage fuses.
Low-voltage electrical inspection of import and export
Part 5. Low voltage fuses
1 Scope
This section provides the import and export of low-voltage fuses sampling, testing and the results of determination.
This section applies to the rated voltage not exceeding 1000V, DC, or no more than 1500V, and is equipped with no less than the rated breaking capacity
6kA enclosed low-voltage current-limiting fuses fuse test.
This section does not apply to small fuse test.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2828.1-2003 Sampling level test - Part 1. Press to accept the quality limit (AQL) retrieval batch test sample
Programme (ISO 2859-1.1999, IDT)
GB/T 2900.18-2008 Electrotechnical term low-voltage electrical
GB 13539.1-2008 Low-voltage fuses - Part 1. General requirements (IEC 60269-1.2006, IDT)
GB/T 13539.2-2008 Low-voltage fuses - Part 2. Supplementary requirements for fuses for use by authorized persons (mainly for workers
Fuses) standardized systems of fuses A sample industry to I (IEC 60269-2.2006, IDT)
GB 13539.3-2008 Low-voltage fuses - Part 3. unskilled personnel Supplementary requirements for fuses (mainly used in home
With fuses and similar applications) example standardized systems of fuses A to F (IEC 60269-3.2006, IDT)
GB/T 13539.4-2009 Low-voltage fuses - Part 4. Supplementary requirements for fuse protection of semiconductor devices of
(IEC 60269-4.2006, IDT)
The basic provisions of SN/T 0002 exports of electromechanical commodity inspection procedures prepared
3 Terms and Definitions
GB/T 2828.1-2003, GB/T 2900.18-2008, GB 13539.1-2008, GB/T 13539.2-2008, GB 13539.3-
2008, GB/T 13539.4-2009 and SN/T 0002 defined by the following terms and definitions apply to this document.
3.1
Sampling mode modeofsamplinginspection
According to the mandatory requirements of national technical specifications, batch import and export commodities or pumping grant implementation sampling, testing and inspection of conformity assessment activities.
3.2
Type Test mode modeoftypetest
According to a predetermined cycle based on the mandatory requirements of national technical specifications type testing, according to on-site inspection requirements for product pumping batch inspection
Inspection, supervision and implementation of the conformity assessment activities of the enterprise quality management system.
3.3
Compliance Verification mode modeofcomplianceverification
According to the mandatory requirements of national technical specifications, check whether the test documents and credentials and match the goods, if necessary, carry out random inspection, and
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 1431.5-2011_English be delivered?Answer: Upon your order, we will start to translate SN/T 1431.5-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 1431.5-2011_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 1431.5-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|