Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 7251.1-2023English1880 Add to Cart 0-9 seconds. Auto-delivery. Low-voltage switchgear and controlgear assemblies - Part 1: General rules Valid
GB 7251.1-2013English145 Add to Cart 0-9 seconds. Auto-delivery. [GB/T 7251.1-2013] Low-voltage switchgear and controlgear assemblies -- Part 1: General rules Obsolete
GB 7251.1-2005EnglishRFQ ASK 8 days Low-voltage switchgear and controlgear assemblies -- Part 1: Type-tested and partially type-tested assemblies Obsolete
GB 7251.1-1997EnglishRFQ ASK 7 days Low-voltage switchgear and controlgear assemblies. Part 1: Type-tested and partially type-tested assemblies Obsolete
GB/T 7251-1987EnglishRFQ ASK 3 days Low-voltage switchgear assembly Obsolete


PDF Preview: GB/T 7251.1-2023


PDF Preview: GB 7251.1-2013


GB/T 7251.1-2023: PDF in English (GBT 7251.1-2023)

GB/T 7251.1-2023 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.130.20 CCS K 31 GB/T 7251.1-2023 / IEC 61439-1:2020 Replacing GB/T 7251.1-2013 Low-Voltage Switchgear and Controlgear Assemblies – Part 1: General Rules (IEC 61349-1:2020, IDT) ISSUED ON: AUGUST 6, 2023 IMPLEMENTED ON: MARCH 1, 2024 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 7 Introduction ... 11 1 Scope ... 13 2 Normative References ... 14 3 Terms and Definitions ... 19 4 Symbols and Abbreviations ... 40 5 Interface Characteristics ... 42 5.1 General ... 42 5.2 Voltage ratings ... 42 5.2.1 Rated voltage (Un) (of the assembly) ... 42 5.2.2 Rated operational voltage (Ue) (of a circuit of an assembly) ... 42 5.2.3 Rated insulation voltage (Ui) (of a circuit of an assembly) ... 42 5.2.4 Rated impulse withstand voltage (Uimp) (of the assembly) ... 42 5.3 Current ratings ... 43 5.3.1 Rated current of an assembly (InA) ... 43 5.3.2 Rated current of a main outgoing circuit (Inc) ... 43 5.3.3 Group rated current of a main circuit (Ing) ... 43 5.3.4 Rated peak withstand current (Ipk) ... 44 5.3.5 Rated short-time withstand current (Icw) (of a main circuit of an assembly) ... 44 5.3.6 Rated conditional short-circuit current (Icc) (of an assembly or a circuit of an assembly) ... 45 5.4 Rated diversity factor (RDF) ... 45 5.5 Rated frequency (fn) ... 45 5.6 Other characteristics ... 46 6 Information ... 46 6.1 Assembly designation marking ... 46 6.2 Documentation ... 47 6.2.1 Information relating to the assembly ... 47 6.2.2 Instructions for handling, installation, operation and maintenance ... 47 6.3 Device and/or component identification ... 48 7 Service Conditions ... 48 7.1 Normal service conditions ... 48 7.1.1 Climatic conditions ... 48 7.1.2 Pollution degree ... 49 7.2 Special service conditions ... 49 7.3 Conditions during transport, storage and installation ... 50 8 Constructional Requirements ... 50 8.1 Strength of materials and parts ... 50 8.1.1 General ... 50 8.1.2 Protection against corrosion ... 51 8.1.3 Properties of insulating materials ... 51 8.1.4 Resistance to ultra-violet (UV) radiation ... 52 8.1.5 Mechanical strength ... 52 8.1.6 Lifting provision ... 53 8.2 Degree of protection provided by an assembly enclosure ... 53 8.2.1 Protection against mechanical impact (IK code) ... 53 8.2.2 Protection against contact with live parts, ingress of solid foreign bodies and water (IP code) ... 53 8.2.3 Assembly with removable parts ... 54 8.3 Clearances and creepage distances ... 54 8.3.1 General ... 54 8.3.2 Clearances ... 55 8.3.3 Creepage distances ... 55 8.4 Protection against electric shock ... 56 8.4.1 General ... 56 8.4.2 Basic protection ... 56 8.4.3 Fault protection ... 57 8.4.4 Additional requirements for class II assemblies ... 61 8.4.5 Limitation of steady-state touch currents and charge ... 62 8.4.6 Operating and servicing conditions ... 62 8.5 Incorporation of switching devices and components ... 64 8.5.1 Fixed parts ... 64 8.5.2 Removable parts ... 65 8.5.3 Selection of switching devices and components ... 65 8.5.4 Installation of switching devices and components ... 66 8.5.5 Accessibility ... 66 8.5.6 Barriers ... 66 8.5.7 Direction of operation and indication of switching positions ... 67 8.5.8 Indicator lights and push-buttons ... 67 8.5.9 Power factor correction banks ... 67 8.6 Internal electrical circuits and connections ... 67 8.6.1 Main circuits ... 67 8.6.2 Auxiliary circuits ... 68 8.6.3 Bare and insulated conductors ... 68 Foreword This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization – Part 1: Rules for the Structure and Drafting of Standardizing Documents. This Document is Part 1 of GB/T 7251 Low-Voltage Switchgear and Controlgear Assemblies. GB/T 7251 has published the following parts: --- Part 1: General Rules; --- Part 2: Power Switchgear and Controlgear Assemblies; --- Part 3: Distribution Boards Intended to be Operated by Ordinary Persons (DBO); --- Part 4: Particular Requirements for Assemblies for Construction Sites (ACS); --- Part 5: Assemblies for Power Distribution in Public Networks; --- Part 6: Busbar Trunking Systems (Busways); --- Part 7: Assemblies for Specific Applications such as Marinas, Camping Sites, Market Squares, Electric Vehicles Charging Station; --- Part 8: General Technical Requirements for Intelligent Assembly; --- Part 10: Guidance to Specifying Assemblies. This Document replaced GB/T 7251.1-2013 Low-Voltage Switchgear and Controlgear Assemblies - Part 1: General Rules. Compared with GB/T 7251.1-2013, the major technical changes of this Document are as follows besides the structural adjustments and editorial modifications: --- Change the scope of the document, and add the description of the inapplicability of this document to the scope, such as power electronic converter systems and equipment (PECS), switch mode power supplies (SMPS), uninterruptible power supplies (UPS), basic drive modules (BDM), complete drive modules (CDM), adjustable speed electrical power drive systems (PDS), and other electronic equipment; (see Clause 1 of this Edition; Clause 1 of the 2013 Edition); --- Add the definition of the rated current of the main circuit group of the complete equipment (see 3.8.10.6 of this Edition); --- Add the interface characteristics of the rated current of the main circuit group of the complete equipment (see 5.3.3 of this Edition); --- Change the requirements and temperature rise verification related to the new characteristic of the group rated current (see 3.8.11, 5.3.1, 5.3.2, 5.4 of this Edition; 3.8.11, 5.3.1, 5.3.2, 5.4 of the 2013 Edition; see 10.10.1, 10.10.2.3, 10.10.4, Annex L of this Edition; 10.10.1, 10.10.2.3, 10.10.4, Annex O of the 2013 Edition); --- Change the relevant provisions related to DC (see 3.7.18, 3.8.9.2, 3.8.10.3, 5.3.5, 9.3.3, 10.9.2, 10.9.3, 10.11.2, 10.11.5.4, Table 9 of this Edition; 3.8.9.2, 3.8.10.3, 5.3.4, 9.3.3, 10.9.2, 10.9.3, 10.11.5.4, Table 9 of the 2013 Edition); --- Change the relevant provisions on electric shock protection, introduce the concept of Class I and Class II complete sets of equipment for electric shock protection, and increase the corresponding requirements and verifications for such complete sets of equipment. (see 3.7.24, 3.7.25, 8.4.3, 10.11.5.6 of this Edition; 8.4.3, 10.11.5.6 of the 2013 Edition). This Document equivalently adopted IEC 61439-1:2020 Low-Voltage Switchgear and Controlgear Assemblies – Part 1: General Rules. The following minimal editorial changes were made to this Document: --- The technical corrigendum of IEC 61439-1:2020/COR1:2021 is incorporated, and the outer margin positions of the involved clauses are marked with vertical double lines (||). Please note some contents of this Document may involve patents. The issuing agency of this Document shall not assume the responsibility to identify these patents. This Document was proposed by China Electrical Equipment Industrial Association. This Document shall be under the jurisdiction of National Technical Committee on Low- Voltage Switchgear and Controlgear Assemblies of Standardization Administration of China (SAC/TC 266). Drafting organizations of this Document: Tianjin Electric Research Institute Limited; Tianjin Tianchuan Electric Control Equipment Inspection Co., Ltd.; China Quality Certification Center; Schneider Electric (China) Shanghai Branch; Zhejiang Testing & Inspection Institute for Mechanical and Electrical Products Quality; Changde Tianma Electrical Co., Ltd.; Guizhou Changtong Electrical Co., Ltd.; Qingdao TGOOD Electric Co., Ltd.; Xiangjiang Technology Co., Ltd.; Zhejiang Chint Electrics Co., Ltd.; Chint Electric Co., Ltd.; Beijing Pursma Electric Technology Co., Ltd.; Shenglong Electric Group Co., Ltd.; Vertiv Technology Co., Ltd.; State Grid Shanghai Energy Internet Research Institute Co., Ltd.; Wuhan Branch of China Electric Power Research Institute; Shanghai Nankong Communication Electrical Equipment Co., Ltd.; Cooper (Ningbo) Electric Co., Ltd.; Shanghai UPUN Electric Group Co., Ltd.; Siemens (China) Co., Ltd. Shanghai Branch; Zhebao Electrical (Hangzhou) Group Co., Ltd.; Guangzhou Baiyun Electric Equipment Co., Ltd.; Shanghai Huajian Electric Switch Co., Ltd.; Wecome Intelligent Manufacturing Co., Ltd.; Sunfly Intelligent Technology Co., Ltd.; Hunan Electric Power Research Institute Testing Group Co., Ltd.; Shanghai Zhezhong Electric Co., Ltd.; Daqo Group Co., Ltd.; Hangzhou Zhijiang Switch Co., Ltd.; HOGN Electrical Group Co., Ltd.; Chuan Kai Electric Co., Ltd.; Siemens Factory Automation Engineering Ltd.; Jiangsu Wetown Distribution Low-Voltage Switchgear and Controlgear Assemblies – Part 1: General Rules 1 Scope This Document lays down the general definitions and service conditions, construction requirements, technical characteristics and verification requirements for low-voltage switchgear and controlgear assemblies. NOTE: Throughout this document, the term assembly(s) (see 3.1.1) is used for a low-voltage switchgear and controlgear assembly(s). For the purpose of determining assembly conformity, the requirements of the relevant part of the IEC 61439 series, Part 2 onwards, apply together with the cited requirements of this document. For assemblies not covered by IEC 61439-3 onward, IEC 61439-2 applies. This document applies to assemblies only when required by the relevant assembly standard as follows: – assemblies for which the rated voltage does not exceed 1 000 V AC or 1 500 V DC; – assemblies designed for a nominal frequency of the incoming supply or supplies not exceeding 1 000 Hz; – assemblies intended for indoor and outdoor applications; – stationary or movable assemblies with or without an enclosure; – assemblies intended for use in connection with the generation, transmission, distribution and conversion of electric energy, and for the control of electrical energy consuming equipment. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.