HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

SN/T 1005-2010 English PDF

US$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 1005-2010: Determination of flavophospholipol residues in meat for import and export. Cylinder plate method
Status: Valid

SN/T 1005: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 1005-2010English419 Add to Cart 3 days [Need to translate] Determination of flavophospholipol residues in meat for import and export. Cylinder plate method Valid SN/T 1005-2010
SN/T 1005-2001English639 Add to Cart 5 days [Need to translate] Dtermination of Flavophospholipol Residues in Meat for Import and Export - Cylinder Plate Method Obsolete SN/T 1005-2001

PDF similar to SN/T 1005-2010


Standard similar to SN/T 1005-2010

GB/T 9959.1   SB/T 10381   SB/T 10294   SN/T 5652.3   SN/T 4747.1   SN/T 4744   

Basic data

Standard ID SN/T 1005-2010 (SN/T1005-2010)
Description (Translated English) Determination of flavophospholipol residues in meat for import and export. Cylinder plate method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard X22
Classification of International Standard 67.120.10
Word Count Estimation 16,110
Date of Issue 2010-01-10
Date of Implementation 2010-07-16
Older Standard (superseded by this standard) SN/T 1005-2001
Quoted Standard SN/T 1750
Regulation (derived from) National Quality Inspection [2010] No. 13
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the import and export of meat in Fula phosphorus residues in the determination of sample preparation and saucer. This standard applies to export pig meat division in Fula phosphorus residues, others may refer to the use of meat.

SN/T 1005-2010: Determination of flavophospholipol residues in meat for import and export. Cylinder plate method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of flavophospholipol residues in meat for import and export. Cylinder plate method Exit inspection and quarantine industry standard book People's Republic of China Instead of the SN/T 1005-2001 Meat Importers Fula phosphorus Residue Detection Plate method Issued on. 2010-01-10 2010-07-16 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

Instead of the standard SN/T 1005-2001 "Meat exports in Fula phosphorus residues in plate method." This standard compared with SN/T 1005-2001, the main changes are as follows. --- Changing the name of the standard; --- The structure and format of the original text of the standard has been revised; --- Regulate the amount of units, symbols of expression; --- The method of preparation of the solution put in Appendix A; --- Deleted the original standard provisions on sampling and inspection lot number; --- Increasing the passage of the test strains and conservation requirements; --- The recovery of the experimental data to a range of values. Appendix A of this standard is a normative appendix. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard by the People's Republic of China Hubei Exit Inspection and Quarantine is responsible for drafting. The main drafters of this standard. Zhao Hui, Wang Peng, Cengxian Dong, Xu Xinsheng, Wuwei Liang, Wang Zhenhua, Contour, Pinghan Li, Chen Jianjun. This standard replaces the standards previously issued as follows. --- SN/T 1005-2001. Meat Importers Fula phosphorus Residue Detection Plate method

1 Scope

This standard specifies the Meat Importers Fula phosphorus residues of sample preparation and assay cup and saucer. This standard applies to import and export pig meat division in Fula phosphorus residues, can refer to the use of other types of meat.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. SN/T 1750 food of animal origin antibiotics residue detection method for microbial inhibition assay

3 Method summary

Extracted with 50% methanol solution in the sample foula phosphorus, homogenized, adjusted to pH 8.0 with sodium hydroxide solution, refluxed for 15min, after cooling Centrifuged and the supernatant was measured plate method. Sample liquid residue Fula phosphorus inhibiting the growth of Bacillus cereus produce inhibition zone from the zone of inhibition The size of a standard curve measured quantitatively meat sample liquid Fula residual phosphorus content.

4 Reagents and materials

Unless otherwise specified, the reagents were of analytical grade, water is distilled water. 4.1 methanol. 4.2 Sodium hydroxide solution. 40% (mass fraction). 4.3 NS. See Appendix A, Section A. Chapter 1. 4.4 buffer Ⅰ (pH7.0). See Appendix A, Section A. 2. 4.5 Fula phosphorus standard stock solution. See Appendix A, Section A. 3. 4.6 Fula phosphorus standard working solution. See Appendix A for the first A. 4. 4.7 Medium Ⅰ. See Appendix A, Section A. 5. 4.8 Medium Ⅱ. Appendix A, Section A. 6. 4.9 Fula phosphorus standards. Residue analysis reference material, suppliers C70H121N5O40P, CAS number. 11015-37-5. Strain and save passage may refer to Appendix B of SN/T 1750. 5. Apparatus 5.1 dish. diameter 90mm, bottom smooth, with terracotta cover. 5.2 Oxford Cup. stainless steel, an outer diameter of 8.0mm ± 0.1mm, an inner diameter of 6.0mm ± 0.1mm, height 10.0mm ± 0.1mm. 5.3 vernier caliper. Measuring range 0mm ~ 150mm, precision 0.02mm; inhibition zone measuring instrument can be used, or other equivalent measuring instruments. 5.4 homogenizer. speed of not less than 10000r/min. 5.5 centrifuge. speed of not less than 3000r/min. 5.6 incubator. 0 ℃ ~ 50 ℃, the shelf should be level.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 1005-2010_English be delivered?

Answer: Upon your order, we will start to translate SN/T 1005-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 1005-2010_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 1005-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version SN/T 1005-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 1005-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.