HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

SN/T 0860-2016 English PDF

US$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 0860-2016: Determination of selenium in food for export
Status: Valid

SN/T 0860: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 0860-2016English229 Add to Cart 3 days [Need to translate] Determination of selenium in food for export Valid SN/T 0860-2016
SN/T 0860-2000English199 Add to Cart 2 days [Need to translate] Method for the determination of selenium in canned mushroom for export. Fluorometry Obsolete SN/T 0860-2000

PDF similar to SN/T 0860-2016


Standard similar to SN/T 0860-2016

NY/T 939   NY/T 2334   SN/T 2051   SN/T 0217.2   SN/T O860   SN/T 0526   

Basic data

Standard ID SN/T 0860-2016 (SN/T0860-2016)
Description (Translated English) Determination of selenium in food for export
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard X04
Word Count Estimation 10,190
Date of Issue 2016-12-12
Date of Implementation 2017-07-01
Regulation (derived from) State-Quality-Inspection-Accreditation (2016) 590; Industry Standard Filing Announcement 2017 No. 8 (Total No. 212)
Issuing agency(ies) General Administration of Customs

SN/T 0860-2016: Determination of selenium in food for export

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of selenium in food for export China's entry-exit inspection and quarantine industry standards Replacing SN/T 0860-2000 Determination of Selenium in Exported Foods Published on.2016-12-12 2017-07-01 Implementation China The State Administration of Quality Supervision, Inspection and Quarantine issued

Foreword

This standard was drafted according to the rules given in GB/T 1.1-2009. This standard replaces SN/T 0860-2000 "Determination of Selenium in Export Mushrooms by Fluorescence Spectrophotometry." The main technical changes of this standard compared with SN/T 0860-2000 are as follows. --- The headline was changed to the determination method for selenium in export foods. The test sample was changed from export canned mushrooms to export food; --- Added the first method of inductively coupled plasma mass spectrometry; --- The original method of fluorescence spectrophotometry is not modified as a second method. This standard is proposed and managed by the National Certification and Accreditation Regulatory Commission. This standard was drafted by. Shanghai Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. Shen Jinchao, Yang Zhenyu, Fan Xiang, Ni Tulu, Chen Zhangting, Song Qing, Li Wei, Zhang Hui. The previous versions of the standards replaced by this standard are. ---SN/T 0860-2000. Determination of Selenium in Exported Foods

1 Scope

This standard specifies the method of inductively coupled plasma mass spectrometry and fluorescence spectrophotometry for the determination of selenium in exported foods. The inductively coupled plasma mass spectrometry method of this standard is applicable to rice, biscuits, milk powder, milk-containing drinks, tea, grapes, peanuts and mushrooms Determination of selenium content in mushrooms and other samples. This standard fluorescence spectrophotometry method is suitable for the determination of selenium content in canned mushrooms.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 6682 Analysis Laboratory Water Specifications and Test Methods First Method Inductively Coupled Plasma Mass Spectrometry

3 Method summary

Selenium in the sample was digested by microwaves and dissolved in an acid solution. Selenium is ionized in the plasma and its characteristic mass is measured Counting, within a certain range, its count rate is proportional to the selenium content. Standard curve internal standard method.

4 Reagents and materials

The test water meets the requirements for secondary water in GB/T 6682. 4.1 65% Nitric Acid. Excellent Grade. 4.2 2% nitric acid. Take 2mL of nitric acid (4.1) and dilute to 100mL with water. 4.3 Isopropyl alcohol. chromatographic purity. 4.4 Selenium standard solution. 1g/L, certified reference material, medium 5% nitric acid. 4.5 Selenium Standard Stock Solution. Diluted selenium standard solution (4.4) to 10mg/L in proportion, and the final medium was nitric acid (4.2). The solution is normal It is valid within 15 days under warm sealed storage conditions. 4.6 Selenium standard curve solution. Diluted selenium standard solution (4.5) in proportion to 5 levels. 0.5μg/L, 1μg/L, 2μg/L, 5μg/L, At 10 μg/L, the final medium was nitric acid (4.2). The solution was effective within 15 days at room temperature in a closed storage condition. 4.7 锗 standard solution. 1g/L, certified reference material. 4.8 internal standard solution. according to the proportion of standard solution (4.7) diluted to 50μg/L, the final medium is nitric acid (4.2), and add isopropyl alcohol (4.3), Mix well so that the final concentration of isopropanol is 0.5% (v/v). The solution is ready for use.

5 Instruments and Equipment

5.1 Inductively Coupled Plasma Mass Spectrometer.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 0860-2016_English be delivered?

Answer: Upon your order, we will start to translate SN/T 0860-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 0860-2016_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 0860-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version SN/T 0860-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 0860-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.